In near-field scanning using H-field probes, E-field coupling is a major concern. E-field suppression performance must be characterized before an H-field probe can be used for near-field scanning. Common method of measurement involves measuring the E-field coupling in the same location where the strongest H-field coupling occurs. In microstrip line traces, it is assumed that this occurs right above the center of the trace and less coupling at all other locations across the microstrip line. In this paper, we show that the maximum E-field coupling occurs at a location slightly offset from the trace center. The E-field coupling to a shielded H-field probe at such a position leads to differential-mode coupling, which the standard shield of an H-field probe is unable to suppress. The coupling mechanism is investigated and a differential E-field coupling suppression approach is proposed. For the H-field probe used in this paper, a proposed floating plate is shown to improve the measured E-field suppression ratio by a factor of 18 dB compared to a similar probe without this modification.
21 March 2018 in IEEE Transactions on Electromagnetic Compatibility
This paper presents a novel passive intermodulation (PIM) prediction method considering random contact behavior using a Monte Carlo method for a coaxial connector. A smart contact model for a contact unit at a microcosmic level is proposed. Using Monte Carlo approximation and micromeasurements, different random distributed contact samples for different contact components inside the coaxial connector are reconstructed. In the experiment, PIM on inner and outer conductor was tested and compared with predication. A good agreement proves the proposed PIM prediction method is efficient. Rather than generating a single PIM prediction value, this method will give a PIM confidence interval for all the potential PIM values considering the contact force statistical behavior. The work will help analyze fluctuated PIM on coaxial connectors and inspire a new method to predict PIM risk.
6 April 2017 in IEEE Transactions on Electromagnetic Compatibility
Creating an equivalent field source is an efficient method for predicting radiated emissions from IC structures. In this paper, the maximum radiated emissions for a heat-sink/IC structure is predicted by creating an equivalent source from the measured electrical field (E-field) in the gap between the heatsink and IC. The E-field is detected by an E-field probe made of an open coaxial cable coated with absorbing material. A numerical model is built in the computer simulation technology microwave studio to obtain the maximum radiated field, where the measured E-field is used as a source to excite the heat-sink model. The evaluated maximum radiated field is in good agreement with the measured value; the error is within 7 dB up to 40 GHz for the source with phase, and 7 dB up to 10 GHz for the phaseless measurement.
24 May 2017 in IEEE Transactions on Electromagnetic Compatibility
A measurement system which uses acoustic vibration to locate passive-intermodulation (PIM) sources in base station antennas is presented. This measurement system uses mechanical vibration to modulate the PIM signal. The modulation of the PIM signal is detected, and its strength or presence/absence is used as guidance for selecting the location of the vibrating transducer. For the method to be successful, the PIM signal must be caused by loose mechanical contacts or loose nonlinear materials. By introducing the acoustic vibration at different locations in the base station antenna and observing if the PIM signal is modulated by the acoustic frequency, the most likely location of the PIM source is identified.
The transfer impedance of a current probe is typically not constant within the current probe's operational frequency range. As it is based on induction, it will suffer from reduced sensitivity at lower frequencies. Thus, a current probe cannot be used directly in a time domain measurement. The low frequency roll-off of a current probe can severely distort the actual waveform. A simple frequency response compensation method is proposed here to enable ESD current measurements with current probes. The method enables a current probe to be used for time domain measurements, such as when measuring ESD transient current and estimating the total transferred charge. If a probe's datasheet provides the transfer impedance for the probe, no additional measurements are needed. Advantages and disadvantages of directly using the measured complex transfer impedance, instead of approximating the transfer impedance by a circuit, is discussed in this paper.
29 February 2016 in IEEE Photonics Technology Letters
In this letter, a high-performance 4H-SiC p-i-n ultraviolet (UV) photodiode (PD) with its p layer formed by Al implantation is designed and fabricated. The dark current density of the PD remains lower than 1 nA/cm 2 at -100 V in the entire temperature range from room temperature (RT) up to 175 °C. The RT maximum external quantum efficiency of the PD under 0 V bias is 44.4% at 270 nm with a UV/visible rejection ratio larger than 104. The photoresponse characteristics of the PD are studied as the functions of reverse bias and temperature, which suggest that the device is advantageous to detect UV signals in high-temperature harsh environment. Compared with a 4H-SiC p-i-n PD formed entirely by epitaxial growth, the PD formed by Al implantation exhibits larger frequency dispersion in capacitance-voltage measurement, which should be caused by residual structural defects introduced during the ion implantation process.