Satyajeet Shinde

Satyajeet Shinde

Auto-generated profile, based on publicly available information

Satyajeet Shinde

Apple Inc., Cupertino, CA, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
SSSatyajeet Shinde
Satyajeet Shinde
KMKohei Masuda
Kohei Masuda
GSGuangyao Shen
Guangyao Shen
APAbhishek Patnaik
Abhishek Patnaik
TMTamar Makharashvili
Tamar Makharashvili
VKVictor Khilkevich
Victor Khilkevich
An equivalent two terminal model based on the Thevenin equivalents describes the common mode (CM) currents on the input and output side of two widely used types of dc-to-dc power converters—buck and boost. Thus, it describes a nonlinear circuit by a linear equivalent circuit. The maximized spectrum of the CM currents is extracted for converters with stochastic signals using a novel characterization procedure. The extracted Thevenin model is used in co-simulation combined with a full-wave electromagnetic solver to predict the radiated emissions from the system consisting of the shielded dc–dc converters with attached cables and a DC brushless motor as load. The results using the terminal model agree well with the measurements providing that the actual CM loads are within the range of CM loads used while obtaining the Thevenin equivalent circuit.

5 June 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Open access
YGYingjie Gan
Yingjie Gan
ATAtieh Talebzadeh
Atieh Talebzadeh
XXXiaoying Xu
Xiaoying Xu
SSSatyajeet Shinde
Satyajeet Shinde
YZYifeng Zeng
Yifeng Zeng
DPDavid Pommerenke
David Pommerenke
This paper is centered on the phenomenological description of spark-less discharges to displays. It analyzes the conduction currents injected onto the glass and the displacement currents flowing through the glass for spark-less discharges to metal-backed glass such as an liquid crystal display (LCD). Further, it provides a full-wave simulation model to reproduce the displacement current flowing through the glass into the display's inner electronic structures. The currents can reach 10 A having pulse widths of tens of nanoseconds. Discharge voltage levels, polarities, approach speed, and humidity influences were investigated. Lichtenberg's dust figure method was used to help visualize the charge distribution and residual charges after surface discharging.

5 March 2018 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
GSGuangyao Shen
Guangyao Shen
SSSatyajeet Shinde
Satyajeet Shinde
APAbhishek Patnaik
Abhishek Patnaik
DPDavid Pommerenke
David Pommerenke
HAHermann Aichele
Hermann Aichele
VKVictor Khilkevich
Victor Khilkevich
A terminal model is a common method to create equivalent models of dc-dc converters in order to predict conducted emissions. In this paper, a characterization method for converters with stochastic behavior is presented. The averaged and maximized spectra of the measured voltages and currents are used to create the model. The phase information is obtained using a dedicated reference channel. After the equivalent source was determined, the actual induced noise voltage at the test load was compared to that predicted by the model with the averaged and maximized spectra to estimate its accuracy. The results indicate that the agreement with the direct measurement is between 10 dB and 100 MHz.

7 August 2019 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
JZJianchi Zhou
Jianchi Zhou
YGYuandong Guo
Yuandong Guo
SSSatyajeet Shinde
Satyajeet Shinde
AHAhmad Hosseinbeig
Ahmad Hosseinbeig
APAbhishek Patnaik
Abhishek Patnaik
DPDavid J. Pommerenke
David J. Pommerenke
Electrostatic discharge (ESD)-induced soft failures are a critical issue for electronic systems as the failures are mostly found after the hardware design is completed. Any changes applied to the hardware may delay the project. Diagnostic tools capable of identifying soft failure-induced malfunctions in an early stage of product design help to reduce the risk of late stage ESD-induced project delays. In many cases, soft failures can be directly observed by the user interface, system crash, or other obvious indicators. However, in an early product design stage the operation system may be marginal and applications may not be available. To improve the ability to detect soft failure critical design choices, this paper presents several methods to identify ESD-induced changes which may not be observable via direct observation. These methods include the observation of ac or dc currents, monitoring dc voltages, capturing near fields and processing them via short-term fast fourier transform (FFT), wavelet transformation, down mixing to audible range, and monitoring for latch-up via thermal imaging. The paper introduces the basis of each method, shows examples, and compares them for their detection ability.

27 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GFGabriel Fellner
Gabriel Fellner
LSLucas Speckbacher
Lucas Speckbacher
SMSeyed Mostafa Mousavi
Seyed Mostafa Mousavi
DPDavid Johannes Pommerenke
David Johannes Pommerenke
SSSatyajeet Shinde
Satyajeet Shinde
CLCheung-Wei Lam
Cheung-Wei Lam
This paper presents a novel peak detect and hold (PDH) circuit for the measurement of the peak voltage of electromagnetic-field probes. These probes are used to capture the fields generated by electrostatic discharge (ESD) events in non-grounded portable devices. Therefore, a circuit combining small size, low power consumption and nano-second operation is needed. A topology using a discrete bipolar transistor structure with OTA and common-base storage capacitor charge control optimally meets the requirements. The circuit performance is demonstrated for different bias point settings. The error between the captured value and the actual pulse peak value is shown as a function of rise time, pulse length, amplitude and bias settings. A comparison with literature, shows unmatched performance with respect to speed and power consumption. Using the bias settings the PDH circuit can be adjusted to the sensor’s frequency response to minimize power consumption in a multi-channel system containing sensors of different bandwidth.

5 March 2025 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
GFGabriel Fellner
Gabriel Fellner
SBSimon Buttinger
Simon Buttinger
DPDavid Pommerenke
David Pommerenke
SSSatyajeet Shinde
Satyajeet Shinde
MHMichael Hillstrom
Michael Hillstrom
The probability of electronic products being affected by electrostatic discharge (ESD) depends on the probability of the device being subjected to ESD and the voltage level. By determining this statistical probability, product risk assessment, and the selection of appropriate ESD test levels can be performed to ensure the targeted field reliability is reached. Obtaining the necessary statistical information about ESD requires methods that can detect and quantify its parameters. Traditional ESD detection methods are predominantly stationary, requiring reference potential, and lack adaptability for portable devices and wearables. This article demonstrates a novel, portable in situ detection method based on on-body electric and magnetic field measurements. The proposed method integrates a wearable ESD sensor, capable of detecting discharge events, estimating voltage and current levels, and differentiating between human skin and human metal discharges. This sensor's design allows the characterization of the complex ESD environments of a person, offering a significant improvement over existing methods. Additionally, integration with a mobile application enables detailed analysis of the discharge scenario through user questionnaires for the first time.