Grzegorz Kiełbasa

Grzegorz Kiełbasa

Auto-generated profile, based on publicly available information

Grzegorz Kiełbasa

First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College , Jakubowskiego 2, Kraków 30-688

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2025 in European Heart Journal
Verified
Journal Article
Open access
MJMarek JastrzęBski
Marek JastrzęBski
GKGrzegorz Kiełbasa
Grzegorz Kiełbasa
ÓCÓscar Cano
Óscar Cano
KCkarol curila
karol curila
FZFrancesco Zanon
Francesco Zanon
HBHaran Burri
Haran Burri
Background and Aims: Left bundle branch area pacing (LBBAP) promotes physiological synchronous activation of the left ventricle and may be particularly beneficial in patients with atrioventricular block (AVB), but its mortality benefit remains unclear. This study aims to compare long-term survival in AVB patients receiving either LBBAP or right ventricular pacing (RVP) and to analyse predictors of mortality during LBBAP. Methods: MELOS RELOADED, a multicentre European collaboration, was a registry-based study of pacemaker patients with AVB, left ventricular ejection fraction (LVEF) >40% and ventricular pacing >20%. The primary outcome was all-cause mortality based on national registries. A 1:1 propensity score matching was performed between the RVP and LBBAP groups. Kaplan–Meier curves and multivariable Cox proportional hazards models were used to estimate survival. Results: In total, 3382 patients receiving LBBAP or RVP were matched. At 4-year follow-up, the Kaplan–Meier curve showed an absolute difference in survival of 11.8% in favour of LBBAP (P < .001). LBBAP was a robust predictor of reduced mortality with a hazard ratio (HR) of 0.53 (95% confidence interval 0.42–0.65, P < .001). Within the LBBAP group, the following independent predictors of increased mortality were identified: lack of confirmed left bundle branch capture (HR 1.85, P < .001), lower percentage of ventricular pacing (HR 1.12), and age. Conclusions: This is the first large study demonstrating the long-term survival benefit of LBBAP. This strengthens the use of LBBAP in AVB patients with preserved/mildly reduced LVEF while awaiting the results of randomized trials. Confirmation of left bundle branch capture seems advisable to achieve optimal results with LBBAP.

15 May 2024 in Heart Rhythm
Verified
Journal Article
Closed access
GKGrzegorz Kiełbasa
Grzegorz Kiełbasa
MJMarek Jastrzębski
Marek Jastrzębski
ABAgnieszka Bednarek
Agnieszka Bednarek
AKAleksander Kusiak
Aleksander Kusiak
TSTomasz Sondej
Tomasz Sondej
PMPaweł Moskal
Paweł Moskal


30 April 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
MJMarek Jastrzębski
Marek Jastrzębski
PMPawel Moskal
Pawel Moskal
ABAgnieszka Bednarek
Agnieszka Bednarek
GKGrzegorz Kiełbasa
Grzegorz Kiełbasa
PVPugazhendhi Vijayaraman
Pugazhendhi Vijayaraman
DCDanuta Czarnecka
Danuta Czarnecka
Background: Strength-duration curves for permanent His bundle (HB) pacing are potentially important for pacemaker programming. Objective: We aimed to calculate strength-duration curve and chronaxie of the His bundle (HB) and of the adjacent right ventricular (RV) working myocardium and to analyze zones of selective HB capture and battery current drain when pacing at different pulse durations (PDs). Methods: Consecutive patients with permanent HB pacing were studied. The RV and HB capture thresholds were assessed at several PDs. Battery current drain and zones of selective HB capture at PDs of 0.1, 0.2, 0.4 and 1.0 ms were determined. Results: In the whole group (n =127) the HB chronaxie was shorter than the RV chronaxie. This difference was driven by patients with selective HB pacing (HB chronaxie of 0.47 vs RV chronaxie of 0.79 ms). Strength-duration curve for HB had lower rheobase and its steep portion started at shorter PDs thus creating wider distance - zone of programmable selective HB pacing - between the HB and RV strength-duration curves at shorter PDs. The battery current drain was lower with pacing at PDs of 0.1 - 0.4 ms vs 1.0 ms. Chronaxie adjusted PDs offered lowest current drain. Conclusion: For the first time the strength-duration curves for permanent selective and non-selective HB pacing were determined. Selective HB capture and battery longevity can be promoted by shorter PDs (0.2 ms). Longer PDs (1.0 ms) offer bigger safety margin for RV capture and may be preferable if simultaneous RV capture during HB pacing is desired.

1 December 2024 in Journal of Innovations in Cardiac Rhythm Management
Verified
Journal Article
Closed access
GKGrzegorz Kiełbasa
Grzegorz Kiełbasa
PMPaweł Moskal
Paweł Moskal
ABAgnieszka Bednarek
Agnieszka Bednarek
MJMarek Jastrzębski
Marek Jastrzębski
SPShunmuga Ponnusamy
Shunmuga Ponnusamy
DKDaniel Keene
Daniel Keene
Physiology of Pacing Symposium 2024: Abstract Finalists