30 December 2024 in IEEE Transactions on Medical Imaging
Single-sided Magnetic Particle Imaging (MPI) devices enable easy imaging of areas outside the MPI device, allowing objects of any size to be imaged and improving clinical applicability. However, current single-sided MPI devices face challenges in generating high-gradient selection fields and experience a decrease in gradient strength with increasing detection depth, which limits the detection depth and resolution. We introduce a novel spatial encoding method. This method combines high-frequency alternating excitation fields with variable offset fields, leveraging the inherent characteristic of single-sided MPI devices where the magnetic field strength attenuates with distance. Consequently, the harmonic signals of particle responses at different spatial positions vary. By manipulating multiple offset fields, we correlate the nonlinear harmonic responses of magnetic particles with spatial position data. In this work, we employed an image reconstruction using a system matrix approach, which takes into account the spatial distribution of the magnetic field during the movement of the device within the field of view. Our proposed encoding approach eliminates the need for the classical selection field and directly links the spatial resolution to the strength and spatial distribution of the magnetic field, thus reducing the dependency of resolution on selection field gradients strength. We have demonstrated the feasibility of the proposed method through simulations and phantom measurements.
29 August 2013 in IEEE Communications Letters
Capture effect is very common in wireless communication systems. In a passive radio frequency identification (RFID) system, even though multiple tags backscatter their signals to a reader simultaneously, one of the tags will be successfully identified due to the capture effect. In this letter, we propose an algorithm which will optimize the identification efficiency of a dynamic frame length ALOHA RFID protocol under capture effect. The proposed algorithm estimates the number of tags and the probability of capture effect. From these parameters, an optimal frame length can be obtained. The advantage of the algorithm is that it does not need many steps to search an extreme value for the estimation. It thus reduces the computational complexity. Computer simulation results show that the proposed method's identification efficiency is almost identical to existing algorithms, but at lower computational complexity.
1 January 2022 in International Journal of Cognitive Informatics and Natural Intelligence
The basic tool in the analytic hierarchy process (AHP) is the complete judgment matrix. To address the weakness of the AHP in determining weight in the comprehensive evaluation system, the particle swarm optimization (PSO)-AHP model proposed in this paper is based on the PSO in the meta-heuristic algorithm. The model was used to solve the indicator weights in the evaluation system of AI education in primary and secondary schools in Fujian Province and was compared with the genetic algorithm and war strategy optimization algorithm. From the comparison results, the PSO-AHP optimization is more effective among the three algorithms, and the indicator consistency can be improved by about 30%. They are both effective in solving the problem that once the judgment matrix is given in the AHP, the weights and indicator consistency cannot be improved. Finally, the results were tested by Friedman statistics to prove the viability of the proposed algorithm.
24 November 2025 in IEEE Transactions on Computational Imaging
Magnetic particle imaging (MPI) is a novel tomographic imaging technique with high sensitivity and high temporal resolution. Reconstruction methods based on the system matrix (SM) enable accurate estimation of the concentration distribution of magnetic nanoparticles. However, SM calibration measurement is highly time-consuming, and the SM needs to be recalibrated whenever the scan parameters, particle types, or even the particle environment change. Although previous studies have proposed methods to accelerate SM calibration, these approaches do not fully exploit the similarity between the two-dimensional (2D) SMs of adjacent slices. In this study, we propose a multi-slice knowledge-driven SM calibration method, MKD-SM, which leverages knowledge obtained from multiple adjacent x-y slices to improve SM calibration accuracy at high downsampling ratios. Specifically, based on the significant similarity of the 2D SMs from adjacent x-y slices, MKD-SM employs a cross-misaligned sampling method to obtain the low-resolution (LR) SM within the field of view (FOV), ensuring that the 2D LR SMs obtained from adjacent slices exhibit complementarity. Additionally, we use a federated affinity fusion method to aggregate the complementary knowledge across multiple adjacent slices and utilize an architecture based on a cascade of CNNs and transformers for high-resolution (HR) SM recovery. Experimental results on the public OpenMPI dataset demonstrate that MKD-SM outperforms existing calibration methods, achieving higher SM calibration accuracy, particularly at high downsampling ratios. Ablation studies confirm the effectiveness of leveraging knowledge from adjacent slices. Furthermore, the proposed method has been successfully applied to an in-house field-free line (FFL) MPI scanner, enabling HR image reconstruction with LR SM measurements.