Qibin Wang

Qibin Wang

Auto-generated profile, based on publicly available information

Qibin Wang

School of Life Science and Technology, Xidian University, Xian, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
QWQibin Wang
Qibin Wang
ZZZhonghao Zhang
Zhonghao Zhang
LLLei Li
Lei Li
FSFranziska Schrank
Franziska Schrank
YZYu Zeng
Yu Zeng
SZSHOUPING ZHU
SHOUPING ZHU
Single-sided Magnetic Particle Imaging (MPI) devices enable easy imaging of areas outside the MPI device, allowing objects of any size to be imaged and improving clinical applicability. However, current single-sided MPI devices face challenges in generating high-gradient selection fields and experience a decrease in gradient strength with increasing detection depth, which limits the detection depth and resolution. We introduce a novel spatial encoding method. This method combines high-frequency alternating excitation fields with variable offset fields, leveraging the inherent characteristic of single-sided MPI devices where the magnetic field strength attenuates with distance. Consequently, the harmonic signals of particle responses at different spatial positions vary. By manipulating multiple offset fields, we correlate the nonlinear harmonic responses of magnetic particles with spatial position data. In this work, we employed an image reconstruction using a system matrix approach, which takes into account the spatial distribution of the magnetic field during the movement of the device within the field of view. Our proposed encoding approach eliminates the need for the classical selection field and directly links the spatial resolution to the strength and spatial distribution of the magnetic field, thus reducing the dependency of resolution on selection field gradients strength. We have demonstrated the feasibility of the proposed method through simulations and phantom measurements.

8 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LLLei Li
Lei Li
YLYidong Liao
Yidong Liao
QWQibin Wang
Qibin Wang
ZZZhonghao Zhang
Zhonghao Zhang
DGDawei Ge
Dawei Ge
JTJie Tian
Jie Tian
Magnetic particle imaging (MPI) is a tracer-based imaging modality known for its high sensitivity and temporal resolution. It makes the quantitative visualization of the concentration and spatial location of magnetic nanoparticles (MNPs) possible. The x-space method is widely used in MPI for high-speed image reconstruction. In this method, the received signal is mapped directly onto the corresponding spatial position. However, the anisotropic 2D point spread function (PSF) in the x-space method introduces artifacts and blur in the reconstructed images. In this study, an isotropic MPI method, transverse MNP signal-based isotropic imaging (TSI), was developed. It makes isotropic imaging possible in 2D unidirectional Cartesian MPI. Unlike conventional methods that rely on MNP signals registered from the same direction as the excitation, TSI only utilizes MNP signals received perpendicular to the excitation direction. In TSI, the velocity of the time domain signal is first normalized to obtain a “raw-image.” The raw-image is then integrated, differentiated, and added to generate an isotropic MPI image. Because all the operations in TSI are analytical, it preserves the real-time imaging characteristics of the x-space while isotropic imaging is performed. The PSF of TSI was calculated through analytical derivation and the resolution isotropy was validated through simulation and imaging experiments on an in-house-built MPI system. The simulation and experimental results demonstrate that, by improving the isotropy, TSI achieves an approximately 2.5-times increase in resolution in the nonexcitation direction compared with the conventional x-space method. The proposed TSI algorithm does not increase hardware complexity and requires only half the scanning time of the previously proposed multi-channel method. In addition, the transverse MNP signal used in TSI is geometrically decoupled from the excitation magnetic field, eliminating the need for a special compensation design for the receiving coils. This shows promise for future MPI designs with flexible surface coils.

24 November 2025 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
PGPengyue Guo
Pengyue Guo
ZWZechen Wei
Zechen Wei
YZYu Zeng
Yu Zeng
BWBingye Wang
Bingye Wang
YLYidong Liao
Yidong Liao
JTJie Tian
Jie Tian
Magnetic particle imaging (MPI) is a novel tomographic imaging technique with high sensitivity and high temporal resolution. Reconstruction methods based on the system matrix (SM) enable accurate estimation of the concentration distribution of magnetic nanoparticles. However, SM calibration measurement is highly time-consuming, and the SM needs to be recalibrated whenever the scan parameters, particle types, or even the particle environment change. Although previous studies have proposed methods to accelerate SM calibration, these approaches do not fully exploit the similarity between the two-dimensional (2D) SMs of adjacent slices. In this study, we propose a multi-slice knowledge-driven SM calibration method, MKD-SM, which leverages knowledge obtained from multiple adjacent x-y slices to improve SM calibration accuracy at high downsampling ratios. Specifically, based on the significant similarity of the 2D SMs from adjacent x-y slices, MKD-SM employs a cross-misaligned sampling method to obtain the low-resolution (LR) SM within the field of view (FOV), ensuring that the 2D LR SMs obtained from adjacent slices exhibit complementarity. Additionally, we use a federated affinity fusion method to aggregate the complementary knowledge across multiple adjacent slices and utilize an architecture based on a cascade of CNNs and transformers for high-resolution (HR) SM recovery. Experimental results on the public OpenMPI dataset demonstrate that MKD-SM outperforms existing calibration methods, achieving higher SM calibration accuracy, particularly at high downsampling ratios. Ablation studies confirm the effectiveness of leveraging knowledge from adjacent slices. Furthermore, the proposed method has been successfully applied to an in-house field-free line (FFL) MPI scanner, enabling HR image reconstruction with LR SM measurements.

28 January 2025 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
QWQibin Wang
Qibin Wang
KYKaixiong Yang
Kaixiong Yang
LHLingwen Hou
Lingwen Hou
HYHaohao Yan
Haohao Yan
YZYu Zeng
Yu Zeng
SZSHOUPING ZHU
SHOUPING ZHU
Magnetic particle spectrometers (MPS), first developed in relation to magnetic particle imaging (MPI) since its introduction in 2005, have been widely applied in biomedical detection and the evaluation of magnetic nanoparticle performance in MPI. Their high sensitivity, low cost, and portability make MPS an essential tool for these applications. However, traditional MPS devices are limited by their enclosed measurement chambers, which restrict their application to solutions placed in small test tubes. Therefore, developing MPS devices that are not constrained by the size of the subject is crucial for clinical applications. Single-sided MPS devices, which concentrate the coils on one side, are not restricted by the size of the object being measured, making them directly applicable to clinical research. However, single-sided MPS devices are currently limited in terms of detection depth and sensitivity due to the rapid attenuation of the magnetic field with distance. To address this issue, in this work, we propose incorporating a soft magnetic core (Mn-Zn ferrite) into the single-sided MPS to enhance the magnetic flux density of the excitation field, thereby increasing detection depth. Additionally, we introduce a surface receiving coil design to replace the traditional solenoidal receiving coil, further improving sensitivity. The results demonstrate that the sensitivity increases by approximately ten times, and the detection depth is doubled.

21 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
NHNing He
Ning He
YGYunpeng Gao
Yunpeng Gao
DGDaiwei Ge
Daiwei Ge
LLLei Li
Lei Li
QWQibin Wang
Qibin Wang
SZSHOUPING ZHU
SHOUPING ZHU
The X-space method is a model-based magnetic particle imaging (MPI) reconstruction algorithm known for its simplicity, speed, and robustness. However, its practical application faces two significant challenges. First, feed-through interference contaminates the fundamental frequency of particle signals, disrupting the physical model utilized for X-space reconstruction. Second, the blurring effect caused by the point spread function (PSF) results in lower resolution in the reconstructed X-space images. In this study, we propose a comprehensive strategy to address these issues and achieve high-resolution images reconstruction. This strategy integrates a compact adaptive-compensation algorithm module implemented on an FPGA, which effectively suppresses feed-through interference and acquires high signal-to-noise ratio (SNR) magnetic particle signals, thereby optimizing X-space reconstruction images. Additionally, by employing the X-space reconstruction physical model as the objective function, we introduce a spatially regularized iterative deconvolution (SRID) method based on an optimization model. This approach enhances the resolution of MPI images through the iterative estimation of the point spread function (IE-PSF) combined with the SRID approach. We conducted numerical and phantom experiments to validate the feasibility of the proposed comprehensive strategy. The results demonstrate that the strategy achieves an MPI image spatial resolution superior to 1 mm under a gradient of 1.25 mT/mm, providing a fourfold enhancement in spatial resolution compared to the conventional X-space method.

1 January 2026 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
QWQibin Wang
Qibin Wang
JLJiashu Li
Jiashu Li
LLLei Li
Lei Li
YLYidong Liao
Yidong Liao
BWBo Wen
Bo Wen
XFXin Feng
Xin Feng