1 July 2018 in Review of Scientific Instruments
In this paper, a time-domain electromagnetic pulse standard field generation setup was designed and manufactured for transient electromagnetic pulse sensor calibration. The calibration setup is based on the mono-cone structure. It can produce a calculated electromagnetic pulse field with the electric field intensity from 100 V/m to 600 V/m. The quantity of the electric field intensity is traced to the national primary standard of the pulse parameter, the S parameter, and the length quantity. The standard uncertainty of the produced electric field is 2.4%. The waveform and field distribution of the standard field were verified by experiment. Based on this facility, the calibration methods and uncertainty evaluation methods for two types of electromagnetic pulse sensors (TEM horn and D-dot sensor) were proposed. Finally, we obtained the calibration results of the sensors. The standard uncertainties of the calibration are 3.6% for the TEM horn and 3.0% for the D-dot sensor.
1 October 2019 in Review of Scientific Instruments
A novel resistive loaded monocone is proposed to extend the time window for pulse electric field calibrations. A resistor array is loaded at the end of a monocone to reduce end reflections. A simulation software was used to optimize the resistive load. Simulations revealed that the optimized loading method can better reduce end reflections compared with conventional approaches. The return loss (S11) was reduced to −18 dB for frequencies from DC to 1 GHz, and the end voltage reflectivity was reduced from 0.14 to 0.05 when the width of the exciting Gaussian pulse was 1 ns. An experimental setup was constructed to verify the optimization scheme and demonstrate the practicality of the design. The measured results of the proposed loaded monocone agreed well with the simulations and are promising for potential applications in future pulsed electromagnetic standard facilities.
1 July 2026 in AIP Advances
This paper proposes a method for real-time synthesis of reconfigurable pulses. The approach employs a high-voltage ultra-wideband (UWB) pulse source as the foundation, utilizing a genetic algorithm (GA) to optimize pulse synthesis parameters for targeted waveform generation. The method achieves not only peak power synthesis but also enables real-time arbitrary waveform synthesis through precise configuration of time delays and switching states of elementary pulses, thereby facilitating flexible switching between operational modes to meet diverse application scenarios. To address the insufficiency of the Pearson correlation coefficient in achieving high-fidelity waveform matching, a multi-objective fitness function is formulated for the GA, enhancing waveform consistency between synthesized and target pulses. Simulation results indicate that the waveform consistency between synthesized and target pulses exceeds 90% for positive Gaussian, negative Gaussian, and bipolar pulses, and surpasses 80% for double-exponential pulses. Experimental validation using a high-voltage UWB pulse source demonstrates that all synthesized positive Gaussian, negative Gaussian, and bipolar pulses achieve waveform consistency above 85% with targets, while double-exponential pulses exceed 75%, verifying the effectiveness of the proposed methodology.