Luca Fachechi

Luca Fachechi

Auto-generated profile, based on publicly available information

Luca Fachechi

Centre for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, Italy

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ASAngela-Tafadwza Shumba
Angela-Tafadwza Shumba
Teodoro MontanaroTeodoro Montanaro
Teodoro Montanaro
Ilaria SergiIlaria Sergi
Ilaria Sergi
LFLuca Fachechi
Luca Fachechi
MVMassimo De Vittorio
Massimo De Vittorio
Luigi PatronoLuigi Patrono
Luigi Patrono
Personalised healthcare has seen significant improvements due to the introduction of health monitoring technologies that allow wearable devices to unintrusively monitor physiological parameters such as heart health, blood pressure, sleep patterns, and blood glucose levels, among others. Additionally, utilising advanced sensing technologies based on flexible and innovative biocompatible materials in wearable devices allows high accuracy and precision measurement of biological signals. Furthermore, applying real-time Machine Learning algorithms to highly accurate physiological parameters allows precise identification of unusual patterns in the data to provide health event predictions and warnings for timely intervention. However, in the predominantly adopted architectures, health event predictions based on Machine Learning are typically obtained by leveraging Cloud infrastructures characterised by shortcomings such as delayed response times and privacy issues. Fortunately, recent works highlight that a new paradigm based on Edge Computing technologies and on-device Artificial Intelligence significantly improve the latency and privacy issues. Applying this new paradigm to personalised healthcare architectures can significantly improve their efficiency and efficacy. Therefore, this paper reviews existing IoT healthcare architectures that utilise wearable devices and subsequently presents a scalable and modular system architecture to leverage emerging technologies to solve identified shortcomings. The defined architecture includes ultrathin, skin-compatible, flexible, high precision piezoelectric sensors, low-cost communication technologies, on-device intelligence, Edge Intelligence, and Edge Computing technologies. To provide development guidelines and define a consistent reference architecture for improved scalable wearable IoT-based critical healthcare architectures, this manuscript outlines the essential functional and non-functional requirements based on deductions from existing architectures and emerging technology trends. The presented system architecture can be applied to many scenarios, including ambient assisted living, where continuous surveillance and issuance of timely warnings can afford independence to the elderly and chronically ill. We conclude that the distribution and modularity of architecture layers, local AI-based elaboration, and data packaging consistency are the more essential functional requirements for critical healthcare application use cases. We also identify fast response time, utility, comfort, and low cost as the essential non-functional requirements for the defined system architecture.

13 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Open access
VCV. Carluccio
V. Carluccio
LFL. Fachechi
L. Fachechi
VMV. M. Mastronardi
V. M. Mastronardi
LNL. Natta
L. Natta
LAL. Algieri
L. Algieri
MVMassimo De Vittorio
Massimo De Vittorio
Piezoelectric microelectromechanical systems (MEMS) meet the growing demand for sensors with small sizes and low power consumption. For tactile applications and pressure measurements, they are applied in various fields from robotics to healthcare. In this context, flexible devices are very important for their high responsivity and ability to conform to the analyzed surface. This work reports on miniaturized flexible and compliant piezoelectric devices to increase the number of integrable sensors for detecting and discriminating localized pressures and contacts per unit area with minimal crosstalk. For this purpose, a series of Aluminium Nitride-based (AlN) piezoelectric sensors with different diameters (from 5 μm to 500 μm) was realized and the generated electrical signal by sensor deformation was amplified by a differential voltage amplifier circuit. By the analysis of the shape of the piezoelectric signal as a function of the applied pressure, oscillations due to piezoelectric deformations, superimposed on the initial peak signal corresponding to the touch event, have been observed. The integral of the electrical signal was calculated for the most accurate representation to describe the sensor’s response. The best responsivity was obtained in samples with diameters of 200 μm and 500 μm. Furthermore, it was also found that the minimum distance between the edges of closed sensors, observing crosstalk below -20 dB, was around 500 μm.

26 January 2024 in IEEE Access
Verified
Journal Article
Open access
ASAngela-Tafadwza Shumba
Angela-Tafadwza Shumba
SDSuleyman Mahircan Demir
Suleyman Mahircan Demir
VMVincenzo Mariano Mastronardi
Vincenzo Mariano Mastronardi
FRFrancesco Rizzi
Francesco Rizzi
GMGaia de Marzo
Gaia de Marzo
MVMassimo De Vittorio
Massimo De Vittorio
Arterial pulse waves contain a wealth of parameters indicative of cardiovascular disease. As such, monitoring them continuously and unobtrusively can provide health professionals with a steady stream of cardiovascular health indices, allowing for the development of efficient, individualized treatments and early cardiovascular disease diagnosis solutions. Blood pulsations in superficial arteries cause skin surface deformations, typically undetectable to the human eye; therefore, Microelectromechanical systems (MEMS) can be used to measure these deformations and thus create unobtrusive pulse wave monitoring devices. Miniaturized ultrathin and flexible Aluminium Nitride (AlN) piezoelectric MEMS are highly sensitive to minute mechanical deformations, making them suitable for detecting the skin deformations caused by cardiac events and consequently providing multiple biomarkers useful for monitoring cardiovascular health and assessing cardiovascular disease risk. Conventional wearable continuous pulse wave monitoring solutions are typically large and based on technologies limiting their versatility. Therefore, we propose the adoption of 29.5 μm-thick biocompatible, skin-conforming devices on piezoelectric AlN to create versatile, multipurpose arterial pulse wave monitoring devices. In our initial trials, the devices are placed over arteries along the wrist (radial artery), neck (carotid artery), and suprasternal notch (on the chest wall and close to the ascending aorta). We also leverage the mechano-acoustic properties of the device to detect heart muscle vibrations corresponding to heart sounds S1 and S2 from the suprasternal notch measurement site. Finally, we characterize the piezoelectric device outputs observed with the cardiac cycle events using synchronized electrocardiogram (ECG) reference signals and provide information on heart rate, breathing rate, and heart sounds. The extracted parameters strongly agree with reference values as illustrated by minimum Pearson correlation coefficients (r) of 0.81 for pulse rate and 0.95 for breathing rate.

12 January 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Ilaria MarascoIlaria Marasco
Ilaria Marasco
GNGiovanni Niro
Giovanni Niro
SDSuleyman Mahircan Demir
Suleyman Mahircan Demir
LMLorenzo Marzano
Lorenzo Marzano
LFLuca Fachechi
Luca Fachechi
MVMassimo De Vittorio
Massimo De Vittorio
Advances in wearable device technology pave the way for wireless health monitoring for medical and non-medical applications. In this work, we present a wearable heart rate monitoring platform communicating in the sub-6GHz 5G ISM band. The proposed device is composed of an Aluminium Nitride (AlN) piezoelectric sensor, a patch antenna, and a custom printed circuit board (PCB) for data acquisition and transmission. The experimental results show that the presented system can acquire heart rate together with diastolic and systolic duration, which are related to heart relaxation and contraction, respectively, from the posterior tibial artery. The overall system dimension is 20 mm by 40 mm, and the total weight is 20 g, making this device suitable for daily utilization. Furthermore, the system allows the simultaneous monitoring of multiple subjects, or a single patient from multiple body locations by using only one reader. The promising results demonstrate that the proposed system is applicable to the Internet of Healthcare Things (IoHT), and particularly Integrated Clinical Environment (ICE) applications.

30 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
LFLuca Fachechi
Luca Fachechi
LBLaura Blasi
Laura Blasi
VMVincenzo Mariano Mastronardi
Vincenzo Mariano Mastronardi
MVMassimo De Vittorio
Massimo De Vittorio
MTMaria Teresa Todaro
Maria Teresa Todaro
Triboelectric nanogenerators exploit the triboelectricity of several materials/structures together with an appropriate device architecture to harvest mechanical energy. These devices usually present high output voltages, high internal impedance and low output currents, and as oscilloscopes are limited by relatively low input impedance, their analysis requires specific instrumentation for the assessment of the main key figures of merit. Due to the increased research interest on this topic, the development of electronic circuits for a rapid and accurate evaluation of the triboelectric nanogenerators performances has become urgent. Here we propose the development of an electronic circuit implemented on a small footprint PCB board. This circuit is based on a differential amplifier probe scheme, is a compact and cost effective approach able to measure both the triboelectric nanogenerators outputs: open circuit voltage at a very high resistive load and short circuit current. Additionally, it offers the possibility to measure voltages under different high resistive loads allowing the assessment of the power behavior of the device. To prove the effectiveness of this approach, triboelectric devices based on carboxymethyl cellulose porous aerogel films have been fabricated and analyzed. Further, experimental results in terms of short circuit currents have been compared with those obtained by using a commercial low noise current amplifier. This approach allows to rapidly and accurately evaluate the behavior of a specific triboelectric device and to effectively compare devices having different characteristics, thus accelerating the development and applications of triboelectric nanogenerators.

11 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
ACAlessandra Corrado
Alessandra Corrado
LPLinda Piscopo
Linda Piscopo
LFLuca Fachechi
Luca Fachechi
FRFrancesco Rizzi
Francesco Rizzi
SMStefania Milanese
Stefania Milanese
FPFerruccio Pisanello
Ferruccio Pisanello
Understanding photo-thermoelastic deformation in thin composite materials is essential for optimizing photoacoustic devices, as the thermoelastic expansion induced by optical absorption governs the generation of acoustic waves. Here, we present a non-contact experimental method to investigate the photothermal deformation dynamics of thin composite films by combining infrared thermography and Laser Doppler Vibrometry (LDV). A burst-modulated nanosecond-pulsed laser is used to induce localized photothermal excitation, while infrared imaging and LDV measurements are employed to characterize the transient temperature evolution and the resulting out-of-plane surface displacement. The method enables detailed analysis of the spatio-temporal dynamics of thermoelastic expansion under controlled excitation conditions. As a proof-of-concept, the approach is applied to PDMS-based nanocomposite films containing black-silicone pigment as absorbers with different thicknesses. The combined analysis of temperature dynamics and surface displacement provides insight into the thermoelastic processes underlying photoacoustic generation and offers a versatile experimental tool for the characterization of photothermal composite materials.