Jian Li

Jian Li

Auto-generated profile, based on publicly available information

Jian Li

School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PZPeng Zhang
Peng Zhang
MHMeng Hou
Meng Hou
Rui LiangRui Liang
Rui Liang
ZTZehua Tang
Zehua Tang
JLJian Li
Jian Li
Nan PengNan Peng
Nan Peng
Incipient cable faults pose a significant risk to the normal operation of power grids. Addressing the issue of detecting incipient faults in underground cables is particularly difficult due to their hidden external characteristics that are not easily observable. Furthermore, these faults occur randomly, with short durations, which further complicates their detection. This paper firstly establishes a cable field-circuit equivalent model that considers multi-conductor electromagnetic coupling for incipient faulty scenarios. The mathematical relationship between the grounding wire currents (GWCs) and fault conditions is then theoretically deduced specifically. A novel method is developed to detect incipient faults in three-core cables by analyzing the time-frequency characteristics of GWC frequency components considering the time-varying fault resistance. The simulation results demonstrate the effectiveness and robustness of the proposed method, showing little impact from fault initial conditions, disturbances, and distributed generations (DGs). Finally, the method is verified in an actual 10 kV distribution network.

13 May 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Nan PengNan Peng
Nan Peng
LXLihua Xu
Lihua Xu
Rui LiangRui Liang
Rui Liang
GZGuangyang Zhou
Guangyang Zhou
PZPeng Zhang
Peng Zhang
YPYihang Pan
Yihang Pan
The insulation of the medium-voltage direct current (MVdc) cable is prone to deterioration due to external and internal factors, which may lead to faults. Aiming to accommodate two different cable operation modes, in this article, the feasibility of decoupling transient measurements is first verified. An algorithm is presented for calculating the phase-mode transformation matrices used for signal decoupling. Then, the states of decoupled modal signals are analyzed to select the featured ones that reflect fault occurrence. A fault detection method is proposed based on the variation characteristics of featured modal signals. Finally, the experimental model of the MVdc cables is created using real-time digital simulation. The experimental results show that the method is independent of the fault condition, cable length, and operating mode. The average fault detection accuracy exceeds 99% with noises equal to or larger than 20 dB. The method applies to a wide range of fault resistances (1–3000 Ω).