Lennart Karstensen

Lennart Karstensen

Auto-generated profile, based on publicly available information

Lennart Karstensen

Friedrich‐Alexander University Erlangen‐Nurnberg

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LKLennart Karstensen
Lennart Karstensen
JRJacqueline Ritter
Jacqueline Ritter
JHJohannes Hatzl
Johannes Hatzl
TPTorben Pätz
Torben Pätz
JLJens Langejürgen
Jens Langejürgen
FMFranziska Mathis-Ullrich
Franziska Mathis-Ullrich
Purpose: The navigation of endovascular guidewires is a dexterous task where physicians and patients can benefit from automation. Machine learning-based controllers are promising to help master this task. However, human-generated training data are scarce and resource-intensive to generate. We investigate if a neural network-based controller trained without human-generated data can learn human-like behaviors. Methods: We trained and evaluated a neural network-based controller via deep reinforcement learning in a finite element simulation to navigate the venous system of a porcine liver without human-generated data. The behavior is compared to manual expert navigation, and real-world transferability is evaluated. Results: The controller achieves a success rate of 100% in simulation. The controller applies a wiggling behavior, where the guidewire tip is continuously rotated alternately clockwise and counterclockwise like the human expert applies. In the ex vivo porcine liver, the success rate drops to 30%, because either the wrong branch is probed, or the guidewire becomes entangled. Conclusion: In this work, we prove that a learning-based controller is capable of learning human-like guidewire navigation behavior without human-generated data, therefore, mitigating the requirement to produce resource-intensive human-generated training data. Limitations are the restriction to one vessel geometry, the neglected safeness of navigation, and the reduced transferability to the real world.

28 May 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LKLennart Karstensen
Lennart Karstensen
JRJacqueline Ritter
Jacqueline Ritter
JHJohannes Hatzl
Johannes Hatzl
FEFloris Ernst
Floris Ernst
JLJens Langejürgen
Jens Langejürgen
FMFranziska Mathis-Ullrich
Franziska Mathis-Ullrich
Purpose: Endovascular intervention is the state-of-the-art treatment for common cardiovascular diseases, such as heart attack and stroke. Automation of the procedure may improve the working conditions of physicians and provide high-quality care to patients in remote areas, posing a major impact on overall treatment quality. However, this requires the adaption to individual patient anatomies, which currently poses an unsolved challenge. Methods: This work investigates an endovascular guidewire controller architecture based on recurrent neural networks. The controller is evaluated in-silico on its ability to adapt to new vessel geometries when navigating through the aortic arch. The controller’s generalization capabilities are examined by reducing the number of variations seen during training. For this purpose, an endovascular simulation environment is introduced, which allows guidewire navigation in a parametrizable aortic arch. Results: The recurrent controller achieves a higher navigation success rate of 75.0% after 29,200 interventions compared to 71.6% after 156,800 interventions for a feedforward controller. Furthermore, the recurrent controller generalizes to previously unseen aortic arches and is robust towards size changes of the aortic arch. Being trained on 2048 aortic arch geometries gives the same results as being trained with full variation when evaluated on 1000 different geometries. For interpolation a gap of 30% of the scaling range and for extrapolation additional 10% of the scaling range can be navigated successfully. Conclusion: Adaption to new vessel geometries is essential in the navigation of endovascular instruments. Therefore, the intrinsic generalization to new vessel geometries poses an essential step towards autonomous endovascular robotics.

15 August 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
LKLennart Karstensen
Lennart Karstensen
HRHarry Robertshaw
Harry Robertshaw
JHJohannes Hatzl
Johannes Hatzl
BJBenjamin Jackson
Benjamin Jackson
JLJens Langejürgen
Jens Langejürgen
FMFranziska Mathis-Ullrich
Franziska Mathis-Ullrich
Endovascular interventions are a life-saving treatment for many diseases, but they suffer from drawbacks such as radiation exposure and the potential scarcity of proficient physicians. Robotic assistance during these interventions could be a promising support for these problems. Research focusing on autonomous endovascular interventions using artificial intelligence-based methodologies is gaining popularity. However, variability in assessment environments hinders the comparability of different approaches, primarily due to each study employing a unique evaluation framework. In this study, we present autonomous endovascular instrument navigation based on deep reinforcement learning for three distinct digital benchmark interventions: BasicWireNav, ArchVariety, and DualDeviceNav. The benchmarks focus on aortic arch to supra-aortic navigation, representing fundamental large-vessel navigation skills. The benchmark interventions were implemented with our modular simulation framework stEVE (simulated EndoVascular Environment). Autonomous controllers were trained solely in simulation and evaluated in simulation and on physical test benches with camera and fluoroscopy feedback. Autonomous control for BasicWireNav and ArchVariety reached success rates up to 98/100 in simulation and was successfully transferred to the physical test benches with a success rate of up to 97/100. The experiments demonstrate the feasibility of stEVE and its potential to transfer simulation-trained controllers to real-world scenarios. However, they also reveal areas that offer opportunities for future research. Furthermore, this work reduces barriers to entry and increases the comparability of research on learning-based assistance systems for endovascular navigation by providing open-source training scripts, benchmarks, and the stEVE framework.

1 July 2022 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
JRJacqueline Ritter
Jacqueline Ritter
LKLennart Karstensen
Lennart Karstensen
JLJens Langejürgen
Jens Langejürgen
JHJohannes Hatzl
Johannes Hatzl
FMFranziska Mathis-Ullrich
Franziska Mathis-Ullrich
CUChristian Uhl
Christian Uhl
Cardiovascular diseases are the main cause of death worldwide. State-of-the-art treatment often includes the process of navigating endovascular instruments through the vasculature. Automation of the procedure receives much attention lately and may increase treatment quality and unburden clinicians. However, in order to ensure the patient’s safety the endovascular device needs to be steered carefully through the body. In this work, we present a collection of medical criteria that are considered by physicians during an intervention and that can be evaluated automatically enabling a highly objective assessment. Additionally, we trained an autonomous controller with deep reinforcement learning to gently navigate within a 2D simulation of an aortic arch. Among others, the controller reduced the maximum and mean contact force applied to the vessel walls by 43% and 29%, respectively.

13 February 2026 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
HRH. Robertshaw
H. Robertshaw
NFN. Fischer
N. Fischer
LKL. Karstensen
L. Karstensen
BJB. Jackson
B. Jackson
XCX. Chen
X. Chen
TBThomas C Booth
Thomas C Booth
Mechanical thrombectomy (MT) is typically the optimal treatment for acute ischemic stroke involving large vessel occlusions, but access is limited due to geographic and logistical barriers. Reinforcement learning (RL) shows promise in autonomous endovascular navigation, but generalization across ‘long’ navigation tasks remains challenging. We propose a Hierarchical Modular Multi-Agent Reinforcement Learning (HM-MARL) framework for autonomous two-device navigation in vitro, enabling efficient and generalizable navigation. HM-MARL was developed to autonomously navigate a guide catheter and guidewire from the femoral artery to the internal carotid artery (ICA). A modular multi-agent approach was used to decompose the complex navigation task into specialized subtasks, each trained using Soft Actor-Critic RL. The framework was validated in both in silico and in vitro testbeds to assess generalization and real-world feasibility. In silico, a single-vasculature model achieved 92–100% success rates on individual anatomies, while a multi-vasculature model achieved 56–80% across multiple patient anatomies. In vitro, both HM-MARL models successfully navigated 100% of trials from the femoral artery to the right common carotid artery and 80% to the right ICA but failed on the left-side vessel superhuman challenge due to the anatomy and catheter type used in navigation. This study presents the first demonstration of in vitro autonomous navigation in MT vasculature. While HM-MARL enables generalization across anatomies, the simulation-to-real transition introduces challenges. Future work will refine RL strategies using world models and validate performance on unseen in vitro data, advancing autonomous MT towards clinical translation.

7 April 2026 in Journal of the American Heart Association
Verified
Journal Article
Open access
HRHarry Robertshaw
Harry Robertshaw
Anna BarnesAnna Barnes
Anna Barnes
PBPhil Blakelock
Phil Blakelock
RBRaphael Blanc
Raphael Blanc
RCRobert Crossley
Robert Crossley
CBChristos Bergeles
Christos Bergeles
Although we are making progress in overcoming infectious diseases and cancer, one of the major medical challenges of the mid‐21st century will be the increasing prevalence of stroke. Occlusions in large vessels are especially debilitating, yet effective treatment—needed within hours to achieve best outcomes—remains limited because of geographic accessibility. One solution for improving timely access to mechanical thrombectomy in geographically diverse populations is the widespread deployment of robotic surgical systems. Artificial intelligence assistance may enable the safe and effective upskilling of operators in this emerging therapeutic delivery approach. Our aim was to establish consensus frameworks for developing and validating artificial intelligence–assisted robots for thrombectomy. Objectives included standardizing effectiveness metrics and defining reference testbeds across in silico, in vitro, ex vivo, and in vivo environments. To achieve this, we convened experts in neurointervention, robotics, data science, health economics, policy, statistics, and patient advocacy. Consensus was built through an incubator day, a Delphi process, and a final position statement. We identified that the 4 essential testbed environments each had distinct validation roles. Realism requirements vary: simpler testbeds should include realistic vessel anatomy compatible with guidewire and catheter use, whereas standard testbeds should incorporate deformable vessels. More advanced testbeds should include blood flow, pulsatility, and disease features, such as atheromatous plaques. There are 2 macroclasses of effectiveness metrics: one for in silico, in vitro, and ex vivo stages focusing on technical navigation (eg, path‐following error), and another for in vivo stages, focused on clinical outcomes (eg, modified treatment in cerebral infarction scores). Patient safety is central, and not a barrier, to this technology's development. One requisite patient safety task needed now is to correlate in vitro measurements to in vivo complications.