Rita Tilmann

Rita Tilmann

Auto-generated profile, based on publicly available information

Rita Tilmann

Imec 1 , Kapeldreef 75, Leuven 3001

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Carbon Trends
Verified
Journal Article
Open access
FRFiliberto Ricciardella
Filiberto Ricciardella
Delft University VollebregtDelft University Vollebregt
Delft University Vollebregt
RTRita Tilmann
Rita Tilmann
OHOliver Hartwig
Oliver Hartwig
CBCian Bartlam
Cian Bartlam
GDGeorg Duesberg
Georg Duesberg

9 March 2026 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
RTRita Tilmann
Rita Tilmann
AFAlexis Franquet
Alexis Franquet
AMAlexandre Merkulov
Alexandre Merkulov
LWLennaert Wouters
Lennaert Wouters
CPClement Porret
Clement Porret
PHPaul van der Heide
Paul van der Heide
Accurate quantification of n-type dopant, such as phosphorus (P) and arsenic (As) in silicon-germanium (SiGe), is critical for source/drain engineering, junction control, and device variability in advanced complementary metal-oxide-semiconductor. Especially for As in SiGe, conventional microanalysis techniques, such as transmission electron microscopy combined with energy dispersive x-ray spectroscopy or electron energy loss spectroscopy, struggle at technologically relevant doping levels and suffer from peak-overlap issues for As in the presence of Ge. Common secondary ion mass spectrometry (SIMS) platforms, such as magnetic sector (MS), quadrupole (Quad), and time-of-flight (ToF), face severe mass interferences at limited mass resolving power as well as low ion yields. Here, we translate the Orbitrap™-SIMS workflow, previously validated for P in Si/SiGe, to As in SiGe, combine it with self-focusing SIMS (SF-SIMS) for patterned features, and benchmark Orbitrap™-SIMS against ToF-SIMS, Quad-SIMS, and MS-SIMS. Using blanket Si1−xGex standards and patterned Ge1−y−zSiySnz:As fins, we show that the exceptional mass resolving power of the Orbitrap™ mass analyzer eliminates the dominant As interferences (e.g., As− vs GeH−; AsSi− vs GeSiH−/29SiGe−/30Si73Ge−; and AsGe− vs 73Ge76Ge−/Ge2H−) and detection limits improve by >1 order of magnitude versus ToF-SIMS and MS-SIMS when SF-relevant clusters are used. As a result, only Orbitrap™-SIMS recovers the physically correct “top-only” As-doped segment in Ge1−y−zSiySnz fins, whereas other mass analyzers erroneously report As throughout the fin due to unresolved overlaps and high backgrounds. These results are confirmed by fast Fourier transform-scanning spreading resistance microscopy 2D carrier distribution mapping.

29 October 2026 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
YZYundong Zhou
Yundong Zhou
RTRita Tilmann
Rita Tilmann
Sascha NowakSascha Nowak
Sascha Nowak
MRMayela Romero-Gomez
Mayela Romero-Gomez
LALuke Antwis
Luke Antwis
IGIan S. Gilmore
Ian S. Gilmore
Secondary ion mass spectrometry (SIMS) is increasingly used to study the surface and interfacial chemistry of battery materials owing to its ppm sensitivity and nanometer depth resolution. To support the community and help improve measurement quality, we measured the sputter yield volumes (SYVs) of a typical LiNi0.6Mn0.2Co0.2O2 (NMC622) cathode composed of compressed particles of active material on a foil current collector support. A time-of-flight (ToF)-SIMS instrument with an in situ atomic force microscope allowed accurate depth measurements giving an SYV for 2 keV Cs+ of 0.040 ± 0.005 nm3/ion and a SYV for 2 keV O2+ of 0.026 ± 0.003 nm3/ion. No evidence of SYV heterogeneity was found. We find that a previously reported sputter rate value in the literature is an order of magnitude lower, highlighting the need for better data. We also determined the Relative Sensitivity Factors (RSFs) for 2 keV O2+ sputtering with a 45° angle of incidence for a 50 keV Co+ implant with a fluence of 1 × 1015 ions/cm2 into silicon and graphite (carbon) as model anode materials. The RSF for silicon (Co+/Si+) is 1.5 ± 0.1 × 1022 atoms/cm3, and the RSF for graphite (carbon) (Co+/C+) is 2.8 ± 0.8 × 1020 atoms/cm3. For graphite, a correction was applied to the C+ signal in the region of the Co+ implant owing to enhanced C+ intensities caused by fragmentation of the carbon lattice.