6 September 2023 in Solid State Phenomena
Aluminum-based alloys, due to their high properties compared to pure aluminum, have expanded their use in building the aircraft strength structures, in the automotive construction and in the naval field. Some of these, such as the radome (aircraft nose) and the wings of the airplane, are exposed also to intense stress from the erosion created by the impact with the raindrops. The literature considers this type of damage to be assimilated by the erosion trough cavitation. Therefore, the paper presents the results of the behavior and resistance to erosion trough vibratory cavitation of the 7075 - T651 aluminum alloy structure, heat treated by artificial aging at 140 °C for 12 hours. The research has been carried out on a standard device that complies with the requirements described in ASTM G32-2016. The structure strength obtained through the researched heat treatment, is evaluated through comparison with the state obtained by artificial aging at 180 °C with a similar duration of 12 hours. The evaluation is done by comparing the parameters recommended by the ASTM G32-2016 norms of the two heat treatments. The results show that the achieved gain is slightly increased.
6 September 2023 in Solid State Phenomena
CSCornelia Laura Salcianu
+2
The good mechanical properties of aluminum alloy 2017 A have determined its use in a wide range of applications in which cavitational solocitations occur, such as hydraulic actuation installations, heat engine blocks, boat propellers and sloops, pumps in the cooling system of thermal engines, wings and ogives of airplanes. Currently, research is focused on the development of procedures for improving the resistance to cavitational erosion of these materials. This paper presents the results of the research on the cavitation erosion behavior of the material subjected to thermal aging treatment at different temperatures of 140 °C and 180 °C respectively and a constant holding time of 12 hours. The research was carried out according to the ASTM G32-2016 norms, on a vibrating device with piezoceramic crystals from the Cavitation Laboratory of the Polytechnic University of Timisoara. The research results, based on characteristic curves, mechanical properties, micro and macro structural images, showed that the sample kept for 12 h at a temperature of 180 °C is weaker than the control sample, during the sample time kept for 12 h at a temperature of 140 °C, has a small increase, even if, compared to the control sample (without heat treatment), the hardness is lower.