Evgeny Demenev

Evgeny Demenev

Auto-generated profile, based on publicly available information

Evgeny Demenev

Fondazione Bruno Kessler, via Sommarive 18, Povo, 38123 Trento, Italy

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Filippo MeleFilippo Mele
Filippo Mele
IDIrisa Dedolli
Irisa Dedolli
MGMassimo Gandola
Massimo Gandola
MGMarco Grassi
Marco Grassi
Piero MalcovatiPiero Malcovati
Piero Malcovati
GBGiuseppe Bertuccio
Giuseppe Bertuccio
The ORION chipset, a full-custom multichip readout and processing electronics for the X- $\gamma $ -ray imaging spectrometer (XGIS) on-board the transient high-energy sky and early universe surveyor (THESEUS) space mission, is presented. The XGIS detection plane is arranged in a matrix of 10 $\times $ 10 detection modules, each one composed of 64 CsI(Tl) scintillation bars (4.5 mm $\times $ 4.5 mm $\times $ 30 mm) optically coupled at the top and bottom ends to two 8 $\times $ 8 monolithic silicon drift detector (SDD) matrices. The top SDD, exposed to the X-ray entrance window, performs the double function of low-energy X-ray detection as well as scintillator’s readout, together with the bottom SDD, providing detection and spectroscopic energy range from 2 keV up to 20 MeV. The need to achieve a high-energy resolution, as well as a high sensitive area on the detection plane, led to the development of a chipset organized to have a minimum-area analog readout chip placed in close proximity of the SDD (ORION-FE) and a mixed-signal back-end (ORION-BE) placed a few centimeters further on the back-end board for the additional signal processing and digitization. The multichip readout electronics integrates two dedicated analog processors for low-energy photons up to 30 keV (X-processor) and high-energy photons up to 5 MeV ( $\gamma $ -processor), allowing a spectroscopy-grade resolution in the 4 decades energy band (2 keV–20 MeV) of the XGIS, with a simulated power consumption of 1.55 mW/pixel. The ORION prototype was bonded to two ~25 mm 2 SDDs, and extensively characterized in terms of pulse shaping, pulse discrimination, and stretching functionality, as well as linearity, dynamic range, and spectroscopic resolution. An optimum equivalent noise charge (ENC) at −20 °C of 24.3 el. r.m.s. on the X-channel [212 eV full-width at half-maximum (FWHM) on Si], and 39.6 el. r.m.s. on the $\gamma $ -channel [3.7 keV FWHM on CsI(Tl)] has been recorded.

27 July 2011 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
EDE. Demenev
E. Demenev
DGDamiano Giubertoni
Damiano Giubertoni
JBJ. van Den Berg
J. van Den Berg
MRM. Reading
M. Reading
MBM. Bersani
M. Bersani

1 February 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
SSSmiriti Srivastava
Smiriti Srivastava
CLC. Labanti
C. Labanti
Lorenzo AmatiLorenzo Amati
Lorenzo Amati
RCRiccardo Campana
Riccardo Campana
EVEnrico Virgilli
Enrico Virgilli
Piero MalcovatiPiero Malcovati
Piero Malcovati
The functionality and experimental performance characterization of the latest four channel version of ORION ASIC, a very low noise multichip read out and processing electronics customized for the X and Gamma Imaging Spectrometer (XGIS) instrument onboard the Transient High-Energy Sky and Early Universe Surveyor (THESEUS) mission, is presented. XGIS is a set of two coded-masked wide field deep sky cameras using monolithic SDDs (Silicon Drift Detectors) and CsI:Tl (Thallium doped-Cesium Iodide) scintillator-based X-γ ray detectors. This paper highlights the design, working principle and the expected performances of the XGIS, on a small scale 2×2 prototype. Furthermore, the evolution timeline of different versions of ORION with detailed performance observations and analysis for spectroscopic resolution, electronic noise and the operational linear energy ranges of both X and the γ processors of the four-pixel ASIC version bonded to a 2×2 SDD array are emphasized. Each 2×2 SDD array element is electrically and dimensionally equivalent to single elements of the THESEUS 8×8 SDD array.

7 November 2012 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
FMF. Meirer
F. Meirer
EDE. Demenev
E. Demenev
DGDamiano Giubertoni
Damiano Giubertoni
SGS. Gennaro
S. Gennaro
LVL. Vanzetti
L. Vanzetti
PPP. Pianetta
P. Pianetta
Samples produced by plasma immersion ion implantation of Arsenic in Silicon using a non-pulsed plasma source and subsequent laser annealing were investigated with respect to As depth distribution, oxide thickness, and As local order using SIMS, XPS, INAA and EXAFS analysis. A surface layer (∼10 nm), was identified as an As-rich Si oxide formed after implantation. The thickness of this layer was found to be larger for samples annealed using a low thermal budget up to a threshold where probably melting occurred. Dopant depth profile was re-distributed whereas the final oxide film of these samples showed thicknesses of a few nm. The retained As dose exhibited an apparent drastic increase. A hypothesis for the processes involved is presented based on experimental evidence.

3 December 2012 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
FMFlorian Meirer
Florian Meirer
DGDamiano Giubertoni
Damiano Giubertoni
EDEvgeny Demenev
Evgeny Demenev
LVLia Vanzetti
Lia Vanzetti
SGSalvatore Gennaro
Salvatore Gennaro
MBMassimo Bersani
Massimo Bersani
Spontaneous growth of arsenolite micro-crystals at room temperature after high fluence, low energy arsenic trihydride implantation in silicon was observed on the wafer surface after exposure to air. The crystals have been identified unambiguously by x-ray absorption and fluorescence spectroscopy. Thermal treatment easily sublimates the crystals at temperatures as low as 200 °C without any relevant in-diffusion of As into the substrate. The deposition of a thin As-rich layer under high fluence implantation conditions is suggested as possible precursor for crystal formation. The same layer can explain the anomalous retained dose increase often observed after annealing.

11 July 2023 in Universe
Verified
Journal Article
Open access
PDF file
RNRiccardo Nicolaidis
Riccardo Nicolaidis
Francesco NozzoliFrancesco Nozzoli
Francesco Nozzoli
GPGiancarlo Pepponi
Giancarlo Pepponi
PBPierluigi Bellutti
Pierluigi Bellutti
EDEvgeny Demenev
Evgeny Demenev
VVVeronica Vilona
Veronica Vilona
An accurate flux measurement of low-energy charged particles trapped in the magnetosphere is necessary for space weather characterization and to study the coupling between the lithosphere and magnetosphere, which allows for the investigation of the correlations between seismic events and particle precipitation from Van Allen belts. In this work, the project of a CubeSat space spectrometer, the low-energy module (LEM), is shown. The detector will be able to perform an event-based measurement of the energy, arrival direction, and composition of low-energy charged particles down to 0.1 MeV. Moreover, thanks to a CdZnTe mini-calorimeter, the LEM spectrometer also allows for photon detection in the sub-MeV range, joining the quest for the investigation of the nature of gamma-ray bursts (GRBs) and terrestrial gamma-ray flashes (TGFs). The particle identification of the LEM relies on the ΔE−E technique performed by thin silicon detectors. This multipurpose spectrometer will fit within a 10 × 10 × 10 cm3 CubeSat frame, and it will be constructed as a joint project between the University of Trento, FBK, and INFN-TIFPA. To fulfil the size and mass requirements, an innovative approach, based on active particle collimation, was designed for the LEM; this avoids the heavy/bulky passive collimators of previous space detectors. In this paper, we will present the LEM geometry, its detection concept, the results from the developed GEANT4 simulation, and some characterisations of a candidate silicon detector for the instrument payload.