24 January 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
BTBruno Trinchera
Bruno Trinchera
DSDanilo Serazio
Danilo Serazio
PUPogliano Umberto
Pogliano Umberto
This paper reports recent progress in developing a new asynchronous digital phase comparator for the precision measurement of phase difference of voltage ratio devices and calibration of functional elements of phasor measurement units (PMUs) calibrator. The phase error of the proposed digital comparator is below 300 nrad at 50 Hz and 100 μrad at 100 kHz with applied voltages ranging between 500 mV and 3 V, whereas the phase error of cables and connectors was estimated to be 4 μrad at 1 MHz. Besides resistive dividers, the phase comparator has been employed for the characterization of frequency behavior of phase difference between the output and input of voltage and transconductance amplifiers for a PMUs calibrator. The system can also be an important tool for phase-frequency characterization of devices employed for specific wideband power measurements.

14 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
ACAlessandro Cultrera
Alessandro Cultrera
GGGabriele Germito
Gabriele Germito
DSDanilo Serazio
Danilo Serazio
FGFLAVIO GALLIANA
FLAVIO GALLIANA
BTBruno Trinchera
Bruno Trinchera
LCLuca Callegaro
Luca Callegaro
Metrological characterisation of static energy meters under realistic low power quality conditions is a basic requirement for proper grid control and fair energy billing. The paper reports about a new proposed methodology, where the meters are tested under conditions directly recorded at installation sites. The waveforms of voltages and currents are sampled using a portable instrument; they are reproduced in laboratory conditions with a phantom power generator, with a bandwidth covering up to the 40th harmonic. The recording site is a photovoltaic energy production facility, having a a nominal power of 50 kW, at the coupling section to the grid. These waveforms were then reproduced in the laboratory, and tested on different models of single- and three-phase commercial static energy meters; the models chosen represent both energy meters used by energy providers at the point of common-coupling, and also meters typically used for in-line monitoring by end users. The quantity of interest is the reading error of the measured energy, when tested with the conditions reproduced from the on-field measurements, in comparison with a reference meter. All tested energy meter models comply with the present international documentary standards, which require tests under low power quality conditions; nevertheless, there are models that show unacceptable errors (up to 25%) in the measurement of active energy when tested with the on-field recorded waveforms. This suggests that the standardised testing waveforms might, in some cases, be not fully representative of the actual conditions encountered in the field.

1 January 2002
Verified
Conference Paper
Closed access
LCL. Callegaro
L. Callegaro
VDV. D'ELia
V. D'ELia
FFF. Francone
F. Francone
DSD. Serazio
D. Serazio

3 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BTBruno Trinchera
Bruno Trinchera
DSDanilo Serazio
Danilo Serazio
A power frequency modular digital sampling power standard (DSPS) is developed and extensively characterized at Istituto Nazionale di Ricerca Metrologica (INRiM) for accurate electric power measurement with a relative uncertainty (k = 1) better than 8 μW/VA. The calibration strategy employed allows to link its key constituents to electrical quantum standards with a relative uncertainty (k = 1) within 3 × 10-6. Comparison measurements against the national power standard at 53Hz agree well within the respective measurement uncertainties and did not exceed 10 μW/VA at 240V and 5A and any power factor. The various novelties introduced make the DSPS a versatile metrological grade measurement setup, which lends well to further improvements and accurate evaluation of electrical parameters involved in power quality measurements. The paper reports the standard, its traceability chain and calibration strategy, comparison measurements and uncertainty budget.