Napat Watjanatepin

Napat Watjanatepin

Auto-generated profile, based on publicly available information

Napat Watjanatepin

Rajamangala University of Technology Suvarnabhumi

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2008 in Renewable Energy
Verified
Journal Article
Closed access
CBChaiyant Boonmee
Chaiyant Boonmee
Boonyang PlangklangBoonyang Plangklang
Boonyang Plangklang
NWNapat Watjanatepin
Napat Watjanatepin

1 October 2018 in Energy and Buildings
Verified
Journal Article
Closed access
DHDong-Hun Han
Dong-Hun Han
SKSedong Kim
Sedong Kim
JCJae Hyuk Choi
Jae Hyuk Choi
YKYeong Sik Kim
Yeong Sik Kim
HCHanShik Chung
HanShik Chung
SCSoon-Ho Choi
Soon-Ho Choi

1 June 2015
Verified
Conference Paper
Closed access
CBChaiyant Boonmee
Chaiyant Boonmee
PSPakorn Somboonkit
Pakorn Somboonkit
NWNapat Watjanatepin
Napat Watjanatepin
The most Grid-connected inverters for photovoltaic (PV) system use the three-level grid-connected inverter, which generates the three voltage level at the output of inverter. It can inject the sinusoidal current to utility grid through a set of filter as shown in Fig. 1. Even though, the three-level grid-connected inverter can be operated in high efficiency, but it still has some drawback, such as, the high total harmonic distortion (THD) of output voltage, the high switching power losses cause by high switching frequency in order to reduce the filter size, and power losses cause by mismatching of PV module power in the same PV string. The cascaded H-bridge multi-level inverter topology is an important choice to reduce some drawback of the three-level grid-connected inverter for PV system as shown in Fig.2. This paper presents the comparison studies the performance of using three-level and cascaded H-bridge multi-level inverter topologies for grid-connected PV system. The both inverter topologies have to operate as a single-phase grid-connected inverter in the same condition of filter size and under the IEEE standard of lower 5% of total harmonic distortion of grid current. The compared performance indicators consist of the grid injected power while the irradiation is changed in two cases (The same size and different size of PV power changing between two sets of PV string). The both systems have to be tested in the same testing condition. The MATLAB/SIMULINK simulation results are verified the accuracy of the both topologies performance.

1 June 2021 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
PKPaiboon Kiatsookkanatorn
Paiboon Kiatsookkanatorn
NWNapat Watjanatepin
Napat Watjanatepin
This paper proposes a novel method to reduce voltage and current ripple for the inverters by using three-level inverters with unipolar pulse width modulation (PWM) (3LFB-2U). A simple technique of switching signal generation by using carrier-based dipolar modulation of three-phase three-level inverters is extended to single-phase inverters that can be done by generating all possible switching patterns of the single-phase three-level inverters. Moreover, the concept of carrier-based dipolar modulation and the construction of reference voltages from desired output voltage and added zero voltage to control unipolar switching is also shown. The research results reveal that the proposed method can reduce the voltage and current ripple. Furthermore, the voltage and current harmonics can reduce by 27.80% and 1.79%, respectively less than two-level inverters without a loss of a simple modulation to generate the switching signals.

1 October 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
NWNapat Watjanatepin
Napat Watjanatepin
KWKhanittha Wannakam
Khanittha Wannakam
PKPaiboon Kiatsookkanatorn
Paiboon Kiatsookkanatorn
CBChaiyant Boonmee
Chaiyant Boonmee
PSPatcharanan Sritanauthaikorn
Patcharanan Sritanauthaikorn
A phosphor-converted light-emitting diode (LED) solar simulator is an illuminance device that produced irradiance intensity and spectral close to the sunlight. It is determined as spectral mismatch, non-uniformity of irradiance, and temporal instability. This paper has improved the LED solar simulator (LSS) system to have a spectral distribution consistent with the AM1.5G spectrum at 100%. It was developed as a new prototype to have the AAA class spectral characteristics, time instability, and inconsistency according to IEC 60904-9. The results showed that an optimal approach was to use phosphor-converted natural white LED (pc-nWLED), combining a monochromatic near-infrared (NIR) (730, 800, 850, 940, and 1,000 nm) as well as the proposed LSS system capable of generating 1,000 W/m2 irradiation over the test plane of 125×125 mm and operated continuously in a constant temperature LED state for at least 2 hours, therefore suitable for demonstration of solar cell features under standard test condition (STC) in the laboratory.

1 January 2022 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
NWNapat Watjanatepin
Napat Watjanatepin
PKPaiboon Kiatsookkanatorn
Paiboon Kiatsookkanatorn
CBChaiyant Boonmee
Chaiyant Boonmee
STSarayoot Thongkullaphat
Sarayoot Thongkullaphat
TATuanjai Archevapanich
Tuanjai Archevapanich
KWKhanittha Wannakam
Khanittha Wannakam
Low-level light therapy (LLLT) uses the light of wavelength between 400–700 nm to treat acne, reduce inflammation, stimulate collagen production, and rejuvenate the facial skin. This study designed and constructed a dual-wavelength LED LLLT device for the facial treatment. The light spectrum, power density, uniformity, stability, and safety of the device were analyzed. The proposed system consisted of an LED array with 415 and 633 nm wavelengths. Human machine interface with embedded system was used to control light intensity and treatment time. The phototherapy device is designed to be curvaceously sized to suit the face shape of Asian people. The results showed that the LLLT device emitted 633±5 nm red and 415±5 nm blue light with a linear adjustable light power density of 0-18.56 mW/cm2 and 0-3.70 mW/cm2, respectively. The spectrum distribution of the red and blue light was relatively constant over 30 minutes of operation. The uniformity and stability of red spectrum were about 89.9% and 95.08% and blue spectrum were 87.6% and 97.08%, respectively. The experimental face’s temperature was below 31.5 . For the future study, the LED phototherapy device will be applied for clinical research in collaboration with dermatologists.Low-level light therapy (LLLT) uses the light of wavelength between 400–700 nm to treat acne, reduce inflammation, stimulate collagen production, and rejuvenate the facial skin. This study designed and constructed a dual-wavelength LED LLLT device for the facial treatment. The light spectrum, power density, uniformity, stability, and safety of the device were analyzed. The proposed system consisted of an LED array with 415 and 633 nm wavelengths. Human machine interface with embedded system was used to control light intensity and treatment time. The phototherapy device is designed to be curvaceously sized to suit the face shape of Asian people. The results showed that the LLLT device emitted 633±5 nm red and 415±5 nm blue light with a linear adjustable light power density of 0-18.56 mW/cm2 and 0-3.70 mW/cm2, respectively. The spectrum distribution of the red and blue light was relatively constant over 30 minutes of operation. The uniformity and stability of red spectrum were about 89.9% and 95.08% and blue spectrum were 87.6% and 97.08%, respectively. The experimental face’s temperature was below 31.5 . For the future study, the LED phototherapy device will be applied for clinical research in collaboration with dermatologists.