Tungsten trioxide nanostructures have received considerable attention due to their enhanced gas sensing properties and promising applications in the sensing field. Herein, tungsten oxide (WO3) with a lamellar structure was prepared by a facile but feasible hydrothermal process and applied for gas detection. The structures, morphologies and surface characteristics of the as-obtained products were characterized by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, transmission electron microscopy and Brunauer–Emmett–Teller analysis. The uniform nanolamellae were constructed from many substructures, primarily nanoparticles, resulting in desirable porous structures. To highlight the potential applications, gas sensors based on the as-synthesized products were fabricated to test their sensing performance. The test data indicated that the porous WO3 nanolamellae had superb kinetic response and remarkable selectivity towards some volatile organic compounds (VOCs), particularly ethanol, at an operating temperature of 200 °C. As such, we believe that these porous WO3 nanolamellae are promising as a potential high-performance sensing material for ethanol detection.
The transmission line parameters vary with the change of temperature, which has a significant impact on power system state estimation (SE). Based on the theory of electro-thermal coordination (ETC), this paper proposes two ETC-SE approaches with the consideration of transmission line temperature. The heat balance equation (HBE) is combined with the conventional weighted least square SE for establishing an ETC-SE model. Moreover, an augmented Jacobian ETC-SE approach is developed by integrating the HBE into pseudo measurements and the line temperature into state vectors. The Jacobian matrix is augmented correspondingly and the partial differential coefficients of measurements to line temperature are provided, which enables to calculate line temperature and voltage phasors simultaneously. Furthermore, in order to accelerate the solving process, an improved two-step ETC-SE algorithm is proposed, in which the SE and temperature estimation are decoupled and solved via alternate iteration. The effectiveness of the proposed ETC-SE approaches is verified by the IEEE 14-, 39-, and 118-bus systems. The results show that the proposed ETC-SE approach is effective to reduce the calculation errors and possesses good convergence performance with varying environmental circumstances and ill-conditioned branches.
1 August 2021 in IOP Conference Series: Earth and Environmental Science
The increasing penetration of renewable energy sources reduces the equivalent inertia and spinning reserve. Power systems are becoming more and more vulnerable when subjected to active power deficits. With the trait of quick response and flexible ramp, the energy storage system (ESS) offers a promising capability to counter frequency decline after large disturbances. This paper proposes an event-driven fast frequency response (EFFR) approach for the ESS to sustain frequency stability. A centralized EFFR control framework is established, in which the wide area information is collected, and the disturbance power is broadcasted to ESSs under contingencies. Moreover, a fuzzy logic controller (FLC) is employed to determine the power set-point of the ESS based on the disturbance power and state of charge (SOC). A case study is presented to validate the feasibility and effectiveness of the proposed approach.
1 August 2021 in IOP Conference Series: Earth and Environmental Science
The DFIGs can participate in frequency control by virtual inertia method. After exiting the frequency control, secondary frequency drop will occur inevitably. The current study of the problem mostly focused on the rotor speed recovery strategy and PD control parameter optimization problems, which cannot eliminate the phenomenon of secondary frequency drop in essence. This paper proposes a frequency control strategy based on the improved virtual inertia control method. When the DFIG exits the frequency modulation process, the supplementary control component based on the turbine speed is added to avoid the sudden drop of output power, so as to suppress the secondary frequency drop. Finally, a simulation model is built in Matlab/Simulink, and the feasibility of the proposed strategy is verified in two case studies of power system frequency reduction and load fluctuation.
In order to make full use of the ability of photo voltaic (PV) units to regulate their own reactive power to participate in voltage stability control of power system, this paper takes full account of the interaction between power grid and PV power plant and proposes a multi-level reactive power control strategy based on sensitivity analysis for PV plant. Firstly, reference of reactive power is calculated combined with the analysis of reactive power and voltage sensitivity of PV power plant and the operation status of power grid. Secondly, reactive power command is allocated to each PV unit according to the reactive power margin. Finally, a reactive power control system model based on an actual PV plant project is established to verify the correctness of proposed strategy in this paper.