Carmen de Mendoza

Carmen de Mendoza

Auto-generated profile, based on publicly available information

Carmen de Mendoza

Department of Infectious Diseases, Hospital Carlos III, Madrid, Spain

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2009 in Retrovirology
Verified
Journal Article
Open access
PDF file
TPThe Spread Programme
The Spread Programme
Dimitrios ParaskevisDimitrios Paraskevis
Dimitrios Paraskevis
OPOliver Pybus
Oliver Pybus
GMGkikas Magiorkinis
Gkikas Magiorkinis
AHAngelos Hatzakis
Angelos Hatzakis
AVAnne-Mieke Vandamme
Anne-Mieke Vandamme
The prevalence and the origin of HIV-1 subtype B, the most prevalent circulating clade among the long-term residents in Europe, have been studied extensively. However the spatial diffusion of the epidemic from the perspective of the virus has not previously been traced. In the current study we inferred the migration history of HIV-1 subtype B by way of a phylogeography of viral sequences sampled from 16 European countries and Israel. Migration events were inferred from viral phylogenies by character reconstruction using parsimony. With regard to the spatial dispersal of the HIV subtype B sequences across viral phylogenies, in most of the countries in Europe the epidemic was introduced by multiple sources and subsequently spread within local networks. Poland provides an exception where most of the infections were the result of a single point introduction. According to the significant migratory pathways, we show that there are considerable differences across Europe. Specifically, Greece, Portugal, Serbia and Spain, provide sources shedding HIV-1; Austria, Belgium and Luxembourg, on the other hand, are migratory targets, while for Denmark, Germany, Italy, Israel, Norway, the Netherlands, Sweden, Switzerland and the UK we inferred significant bidirectional migration. For Poland no significant migratory pathways were inferred. Subtype B phylogeographies provide a new insight about the geographical distribution of viral lineages, as well as the significant pathways of virus dispersal across Europe, suggesting that intervention strategies should also address tourists, travellers and migrants.

1 March 2008 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
CGCarolina Garrido
Carolina Garrido
VRVanessa Roulet
Vanessa Roulet
NCNatalia Chueca
Natalia Chueca
Eva PovedaEva Poveda
Eva Poveda
AAAntonio Aguilera
Antonio Aguilera
CMCarmen de Mendoza
Carmen de Mendoza
Human immunodeficiency virus type 1 (HIV-1) tropism can be assessed using phenotypic assays, but this is quite laborious, expensive, and time-consuming and can be made only in sophisticated laboratories. More accessible albeit reliable tools for testing of HIV-1 tropism are needed in view of the prompt introduction of CCR5 antagonists in clinical practice. Bioinformatics tools based on V3 sequences might help to predict HIV-1 tropism; however, most of these methods have been designed by taking only genetic information derived from HIV-1 subtype B into consideration. The aim of this study was to evaluate the performances of several genotypic tools to predict HIV-1 tropism in non-B subtypes, as data on this issue are scarce. Plasma samples were tested using a new phenotypic tropism assay (Phenoscript-tropism; Eurofins), and results were compared with estimates of coreceptor usage using eight different genotypic predictor softwares (Support Vector Machine [SVM], C4.5, C4.5 with positions 8 to 12 only, PART, Charge Rule, geno2pheno coreceptor, Position-Specific Scoring Matrix X4R5 [PSSM X4R5 ], and PSSM sinsi ). A total of 150 samples were tested, with 115 belonging to patients infected with non-B subtypes and 35 drawn from subtype B-infected patients, which were taken as controls. When non-B subtypes were tested, the concordances between the results obtained using the phenotypic assay and distinct genotypic tools were as follows: 78.8% for SVM, 77.5% for C4.5, 82.5% for C4.5 with positions 8 to 12 only, 82.5% for PART, 82.5% for Charge Rule, 82.5% for PSSM X4R5 , 83.8% for PSSM sinsi , and 71.3% for geno2pheno. When clade B viruses were tested, the best concordances were seen for PSSM X4R5 (91.4%), PSSM sinsi (88.6%), and geno2pheno (88.6%). The sensitivity for detecting X4 variants was lower for non-B than for B viruses, especially in the case of PSSM sinsi (38.4% versus 100%, respectively), SVM wetcat (46% versus 100%, respectively), and PART (30% versus 90%, respectively). In summary, while inferences of HIV-1 coreceptor usage using genotypic tools seem to be reliable for clade B viruses, their performances are poor for non-B subtypes, in which they particularly fail to detect X4 variants.

1 April 2009 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
PDF file
CGCarolina Garrido
Carolina Garrido
NZNatalia Zahonero
Natalia Zahonero
ACAngélica Corral
Angélica Corral
MAMiguel Arredondo
Miguel Arredondo
VSVincent Soriano
Vincent Soriano
CMCarmen de Mendoza
Carmen de Mendoza
The plasma human immunodeficiency virus (HIV) RNA load is used in the clinical routine for the monitoring of HIV infection and the patient9s response to antiretroviral therapy. Other body fluids or dried blood spots (DBS) can be used, however, to assess the level of viremia. The use of DBS may be especially helpful for the monitoring of HIV-infected patients in resource-poor settings, where access to adequate laboratory facilities is often difficult. However, the correlation between the HIV RNA levels in plasma and those in DBSs has not been well established. Paired plasma and DBS samples obtained from HIV type 1 (HIV-1)-infected patients were tested for HIV RNA copy numbers by using two different commercial assays, the Nuclisens EasyQ HIV-1 (version 1.1) test (the Nuclisens test; Biomerieux) and the m2000rt RealTime HIV test (the m2000rt test; Abbott). Nucleic acid extraction was performed manually by using either the Nuclisens isolation kit (which uses the Boom methodology) or the m2000rt sample preparation kit (an iron particle-based method). A total of 103 paired plasma and DBS samples were tested. Viral load results were obtained for 97 (94.2%) samples with the Nuclisens isolation kit and 81 (78.6%) samples with the m2000rt kit. The overall correlation between the RNA loads in plasma and DBS was good, although better results were obtained by the Nuclisens test (R2 = 0.87, P < 0.001) than by the m2000rt test (R2 = 0.70, P < 0.001). While the specificities were excellent and similar for both the Nuclisens and the m2000rt tests (97.1% and 100%, respectively), the sensitivity was greater by the Nuclisens test than by the m2000rt test (75.8% and 56.6%, respectively). Overall, the viral loads in DBS tended to be lower than those in plasma, with mean differences of 0.3 log unit (standard deviation, 0.5 log unit) and 0.76 log unit (standard deviation, 0.8 log unit) for the Nuclisens and the m2000rt tests, respectively. The levels of agreement between the measurements in plasma and DBS were assessed by using the Bland-Altman plot for each assay. The Nuclisens test gave results within its defined limits (−0.65 to 1.26) for 95.9% of the samples, while the m2000rt test gave results within its limits (−0.83 to 2.33) for 100% of the samples. In summary, the HIV-1 load can accurately be quantified by testing DBS by either the Nuclisens or the m2000rt test, although the Nuclisens test may outperform the m2000rt test when nucleic acids are extracted manually.

27 February 2007 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
CMCarmen de Mendoza
Carmen de Mendoza
CRCarmen Rodriguez
Carmen Rodriguez
FGFederico García
Federico García
JEJose Maria Eiros-Bouza
Jose Maria Eiros-Bouza
LRLidia Ruíz
Lidia Ruíz
VSVicente Soriano
Vicente Soriano
HIV-1 co-receptor usage may play a critical role in AIDS pathogenesis. Information on viral tropism in HIV-1 seroconverters is scarce, as is the relationship with transmission of drug-resistant viruses. All consecutive HIV-1 seroconverters seen between January 1997 and December 2005 in 17 Spanish hospitals were retrospectively analysed. V3 loop amino acid sequences derived from plasma RNA at the time of initial diagnosis were used to predict co-receptor usage. Major drug resistance mutations, plasma HIV RNA, CD4 counts and HIV subtype were considered for subsequent analyses. A total of 296 HIV-1 seroconverters were identified (84% male; median age 30 years; 61% homosexual men). Median estimated time from infection was 7 months (interquartile range, 3–11). Primary drug resistance mutations were seen in 12.5%, being 9.5% for nucleoside reverse transcriptase inhibitors (NRTI), 4.4% for non-NRTI (NNRTI) and 3% for protease inhibitors (PI). Twenty-four (8.1%) carried non-B subtypes. HIV tropism could be characterized in 203 seroconverters (69%). X4 viruses (either pure or dual/mixed R5/X4) were recognized in 35 (17.2%). There was no association between HIV tropism and mean plasma HIV RNA (4.5 versus 4.4 log copies/mL in R5 versus X4, respectively; P = 0.45) or mean CD4 counts (594 versus 554 cells/mm3, respectively; P = 0.48). The proportion of X4 viruses did not differ in patients infected with wild-type or drug-resistant viruses (17% versus 18%, P = 1). Intravenous drug users tended to show X4 viruses more frequently than individuals infected by sexual relationships (35.7% versus 16.5%, respectively; P = 0.073). After 12 months of follow-up in 78 seroconverters who did not start antiretroviral therapy, more pronounced increases in plasma HIV RNA (+5056 versus −3430) and declines in CD4 cell counts (−126 versus −60) were seen in X4 compared with R5 carriers. A significant proportion of recent HIV-1 seroconverters harbour X4 viruses (17.2%), without any evidence of association between co-receptor usage, transmission of drug-resistant viruses and HIV subtype.

28 April 2010 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
ESEduardo SeclÉN
Eduardo SeclÉN
CGCarolina Garrido
Carolina Garrido
MGMarÍA del Mar GonzÁLez
MarÍA del Mar GonzÁLez
JGJuan GonzÁLez-Lahoz
Juan GonzÁLez-Lahoz
CMCarmen de Mendoza
Carmen de Mendoza
Eva PovedaEva Poveda
Eva Poveda
Evaluation of the reliability of several V3-based genotypic predictors to infer viral tropism in patients infected with B and non-B strains of HIV-1. Several genotypic tropism predictors were evaluated in plasma (RNA) samples from 198 HIV-1-infected patients, taking as gold standard the results of the phenotypic recombinant virus assay Phenoscript®. In addition, for 37 B subtype HIV-1 patients the phenotypic results from plasma samples were also compared with tropism predictions based on V3 amplification from paired peripheral blood mononuclear cells (PBMCs). A total of 150 paired genotypic/phenotypic results were obtained from plasma specimens. Concordance values ranged from 63% to 85%, depending on the genotypic algorithm used. The best predictors in terms of sensitivity/specificity to detect X4 variants were WebPSSMX4/R5 (77%/87%), Geno2phenoFPR = 5% (80%/77%) and an algorithm combining the ‘11/25’ and ‘Net charge’ rules, termed Garrido's rule (80%/79%). The performance of genotypic predictors was better testing B than non-B clades. The overall sensitivity ranged from 28% to 94%, reaching 100% in subtype B antiretroviral-experienced patients using WebPSSMSI/NSI, Geno2phenoFPR ≥ 5% and Garrido's rule. Conversely, the sensitivity when testing non-B subtypes was poorer, ranging from 17% to 67%. Interestingly, the correlation between genotypic and phenotypic results was better when testing PBMCs than plasma using all genotypic predictors. Genotypic tools based on V3 sequences may provide reliable information on HIV-1 tropism when testing clade B viruses, especially in antiretroviral-experienced patients. The sensitivity to detect X4 variants using genotypic tools may improve by testing proviral DNA instead of plasma RNA.

24 January 2008 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
CGCarolina Garrido
Carolina Garrido
NZNatalia Zahonero
Natalia Zahonero
DFDiana FernáNdes
Diana FernáNdes
DSDulcelina Serrano
Dulcelina Serrano
ASAna Rita Silva
Ana Rita Silva
CMCarmen de Mendoza
Carmen de Mendoza
Subtype variability may influence treatment response and selection of drug resistance mutations in HIV-positive patients on antiretroviral therapy. A retrospective study was performed on specimens collected on dried blood spots (DBS) from HIV-positive individuals receiving antiretroviral therapy in Luanda, Angola. HIV-RNA, drug resistance mutations and subtypes were examined in 294 HIV-positive patients treated with two nucleoside analogues (NA) plus one non-nucleoside reverse transcriptase inhibitor (NNRTI). Overall, 217 (74%) had <1000 HIV-RNA copies/mL after a median of 12 months (range 7–24) of therapy. CD4 count was significantly higher in subjects with undetectable viraemia compared with viraemic patients (294 versus 220 cells/mm3; P = 0.003). Reverse transcriptase and/or gp41 genes could be genotyped in only 45 (58%) of viraemic patients, probably due to poor storage conditions of DBS. The most frequent resistance mutations were M184V (70%) and K103N (39%); 65% had mutations conferring resistance to both NA and NNRTI. Only five patients did not show resistance mutations. A wide HIV-1 subtype heterogeneity was found: 6 C (18.2%), 2 F (6%), 2 H (6%), 1 D (3%), 1 G (3%), 8 CRF02_AG (24.2%), 2 CRF06 (6%), 1 CRF01_AE (3%), 1 CRF14_BG (3%), 1 CRF25 (3%) and 1 CRF19 (3%). HIV clade could not be assigned in 7 (21%). Nearly three-quarters of HIV-positive individuals who began an NNRTI-based triple regimen in Angola showed undetectable viraemia after a median of 12 months of therapy, a rate similar to that reported in Western countries. Specimens collected on DBS may allow monitoring of treatment response in resource-limited regions, although adequate temperature and humidity storage conditions are important to ensure RNA stability and further successful testing.