Peter J. Littrup

Peter J. Littrup

Auto-generated profile, based on publicly available information

Peter J. Littrup

University of Rochester Medical Center, Rochester NY, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Radiology: Imaging Cancer
Verified
Journal Article
Closed access
JJJack W. Jennings
Jack W. Jennings
JPJ. David Prologo
J. David Prologo
JGJulien Garnon
Julien Garnon
AGAfshin Gangi
Afshin Gangi
XBXavier Buy
Xavier Buy
FDFrederic Deschamps
Frederic Deschamps
Cryoablation is a safe and minimally invasive therapy option that provided rapid and durable pain relief, as well as an improved quality of life in participants with bone metastases. Purpose To assess the clinical effectiveness of cryoablation for palliation of painful bone metastases. Materials and Methods MOTION (Multicenter Study of Cryoablation for Palliation of Painful Bon...

7 August 2024 in International Journal of Hyperthermia
Verified
Journal Article
Open access
DBDavid Bustamante
David Bustamante
YYYan Yan
Yan Yan
TMTrevor Mitcham
Trevor Mitcham
RARehman Ali
Rehman Ali
BMBrian Marples
Brian Marples
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
To demonstrate the feasibility of using a ring array ultrasound (US) transducer, guided by ultrasound tomography (UST), for generating and monitoring mild hyperthermia (MHTh). In silico and in vitro experiments were designed to evaluate the efficacy of a ring array US transducer for generating MHTh and monitoring changes in temperature. In a series of in silico studies, we compared the acoustic focal profiles produced by a ring array US transducer transmitting at different frequencies and further investigated the effectiveness of UST-guidance in implementing aberration correction to enhance the focal profile. In vitro experiments evaluated the capability of using a ring array US transducer to generate and maintain MHTh and the accuracy of using UST to monitor temperature changes. The simulations demonstrated that a ring array US transducer achieves symmetrical and localized acoustic focusing. In a heterogenous tissue model, a ring array US transducer achieved a superior acoustic focus by implementing aberration correction with guidance from UST. In vitro experiments demonstrated the capability of a ring array US transducer to generate MHTh in a tissue-mimicking phantom in an average of 117 ± 18 s and subsequently maintain MHTh. Lastly, a ring array US transducer utilized UST to track temperature changes in a preheated water-filled inclusion while it passively cooled from 45 °C to 25 °C, with a maximum error of 0.58 °C. A ring array US transducer can noninvasively generate and monitor MHTh, overcoming many limitations of current clinical systems. The closed geometry of the transducer is optimal for acoustic focusing and UST-guidance allows for improved aberration correction in a heterogenous medium. Utilizing UST thermometry with the same ring array US transducer will allow for implementing an image-guided, temperature-controlled, all-acoustic MHTh system.

11 October 2025 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
NKNikiforos Vasiniotis Kamarinos
Nikiforos Vasiniotis Kamarinos
PLPeter J. Littrup
Peter J. Littrup
Constantinos T. SofocleousConstantinos T. Sofocleous
Constantinos T. Sofocleous
SSStephen B. Solomon
Stephen B. Solomon
RWRobert C Ward
Robert C Ward