Wei Zou

Wei Zou

Auto-generated profile, based on publicly available information

Wei Zou

National Institute of Metrology

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZWei Zou
Wei Zou
ZWZhenzhong Wei
Zhenzhong Wei
In many measurement applications using multicameras, there is often a nonoverlapping field of view (nFOV) between multicameras. It benefits greatly from having all of the cameras unified in a single coordinate frame by means of common spatial constraints. However, it is very difficult to establish common spatial constraints for accurate and quick calibration of the extrinsic parameters between multicameras in the case of long working distance, asymmetric working angle, or limited working space. To overcome these issues, we propose a flexible calibration method using a camera rig, which can be easily modeled as a hand–eye calibration problem and solved by only several sets of calibration images. To further improve the calibration accuracy, the camera intrinsic parameters, lens distortion coefficients, and extrinsic parameters are optimized simultaneously, similar to binocular calibration. However, this causes calculation instability of multiparameters. We extend the epipolar constraint to two images with an nFOV and add it into the optimization objective function together with the reprojection error, which ensures the basic consistency of intrinsic parameters before and after optimization, and reduce the fluctuation caused by the number of images involved in calibration. Experiments and application have proved that the proposed new methods are feasible and effective.

8 January 2021 in Optics Express
Verified
Journal Article
Closed access
PDF file
HGHongtang Gao
Hongtang Gao
ZWZhongyu Wang
Zhongyu Wang
WZWei Zou
Wei Zou
YLYuzhang Liu
Yuzhang Liu
SSShuanghua Sun
Shuanghua Sun
A measurement system based on a simple double-beam interferometry is built to realize the measurement of air refractive index with high accuracy. The basic principle of the system is that, through measuring the change of optical path difference caused by rapid and smooth vacuumization, measurement of refractive index of air is converted to length measurement. Error correction and signal processing are studied to ensure high-accuracy measurement of the refractive index of air. Three applicable methods are used in system. The system based on the methods realize the subdivision and counting of interference fringe by software with three-error correction, error compensation for the end-window plates’ thickness change caused by vacuumization, steady realization of high vacuum conditions. To verify the accuracy and reliability of the system, the measurement results are compared with that obtained from the method based on empirical Edlén’s formula. Analysis result shows that the expanded measurement uncertainty of the system is U = 5×10−9, with k = 2. The system can be used to compensate the laser wavelength error caused by the refractive index of air with high accuracy.

26 August 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZWei Zou
Wei Zou
YHYao Huang
Yao Huang
HLHu Lin
Hu Lin
ZXZi Xue
Zi Xue
Ring laser gyroscope is one of the most important equipment in high-precision strapdown inertial navigation systems, and has been widely used in the field of navigation. At present, there is little research on the application of ring laser gyroscope on the angle error measurement of sub-arc-second in the metrology field, and it has not been officially used as the metrology standard instrument. Aiming at the inaccurate measurement of ring laser gyroscope in metrology due to zero position drift and non-coplanar installation, a non-contact high-precision angle measurement error measurement method is proposed in this paper. Firstly, the original scale factor is calculated on the standard rotating device to avoid re-calculated on the measured device and solve the traceability problem. Secondly, the influence of the installation error between the turntable and the laser gyroscope goniometer on the angle measurement error is analyzed, and the compensation method of angle measurement error in the online measurement of the laser gyroscope is proposed. Finally, the feasibility of online metrology of ring laser gyroscope is verified by experiments, and the measurement uncertainty is estimated. The online measurement results show that compared with the photoelectric autocollimator (measurement uncertainty is U = 0.07ʺ ( k = 2), the angle measurement error of the ring laser gyroscope goniometer in multi-axis turntable is ±0.4ʺ, and the measurement uncertainty is U = 0.36ʺ ( k = 2).

1 June 2014
Verified
Conference Paper
Closed access
QWQingbin Wang
Qingbin Wang
WZWei Zou
Wei Zou
FZFeng Zhang
Feng Zhang
DXDe Xu
De Xu
A simple binocular visual equipment is designed in this paper, which is mainly composed by two CCD cameras and four stepping motors. Firstly, the two cameras' initial location is determined based on rough location by moving to the limiting position, and precise location by driving the image center aligning with fitted ellipse center. Then, the transformation matrix between coordinate systems of motion module end and the camera is calibrated with eye-in-hand calibration method, which adopts multi frame images and a method based on Levenberg-Marquardt iterative algorithm to improve its precision and robustness. Finally, the updating equations of transformation matrix between two camera's coordinate systems are deduced with high precision and real-time property to guarantee the binocular visual system's depth perception. The performance of the above methods is confirmed by comparative experiments.

16 November 2023 in Photonics
Verified
Journal Article
Open access
PDF file
YHYao Huang
Yao Huang
SCShuangliang Che
Shuangliang Che
WZWeibin Zhu
Weibin Zhu
CMCheng Ma
Cheng Ma
YZYi Zhou
Yi Zhou
ZXZi Xue
Zi Xue
In view of the limitations of the existing eccentricity error separation method of the rotary table, an eccentricity error separation method based on the phase feature of the moiré signal of a single reading head is proposed herein. A grating pair transmission model is established based on the analysis of the principle of the rotary table; thereby, the influence of eccentricity error on the phase feature of the moiré signal in the rotation course of the rotary table is clarified, and the corresponding model between the phase feature spectral components and the eccentricity error is established. The verification experiments of the proposed method are carried out based on the laboratory-made circuit system. After verifying the accuracy of the data acquisition of the laboratory-made circuit board, the verification experiments of the eccentricity error separation effect of the proposed method are carried out. The experimental data are compared with those of the traditional method, and the results show that the error between the two methods is 2.34 μm, while the relative error is 2.3%.

26 August 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZWei Zou
Wei Zou
YHYao Huang
Yao Huang
HLHu Lin
Hu Lin
ZXZi Xue
Zi Xue
This paper gives a new application of laser gyro in the field of metrology, that is, the perpendicularity measurement method between two axes of multi-axis turntables based on single-axis laser gyro goniometer. This method skillfully establishes different coordinate frames on the turntable and uses the projection variation of the sensitive axis of the laser gyro in the coordinate frame to solve the perpendicularity. This method can also accurately solve the misalignment angle of the laser gyro goniometer at the same time. It is suitable for online measurement of perpendicularity between the axes of multi-axis turntables in fields such as CNC machine tools, robots, flight simulation, and inertial testing. This method has simple equipment installation, convenient measurement operation, high measurement accuracy (the measurement uncertainty is U = 0.23′′ (k = 2), and fully utilizes the dynamic characteristics of the laser gyro goniometer.