Zi Xue

Zi Xue

Auto-generated profile, based on publicly available information

Zi Xue

National Institute of Metrology

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZWeibin Zhu
Weibin Zhu
YXYingkun Xu
Yingkun Xu
YHYao Huang
Yao Huang
ZXZi Xue
Zi Xue
SYShengjin Ye
Shengjin Ye
Moiré signal subdivision is essential to the application of gratings. Focusing on the complexity and difficulty of quadrature compensation for the Moiré signals, we propose a new method that can directly subdivide nonorthogonal Moiré signals. A detailed description of the digital subdividing system for this method is provided herein. Compared with conventional methods, the proposed method requires fewer hardware resources and features shorter delays. The effects of various parameters on the subdivision process are discussed, and the quantitative relationships between the signal amplitude ratio, signal sampling frequency ratio, and subdivision value are determined. Finally, evaluation tests are performed using a laboratory-made field-programmable gate array subdivision circuit. The results confirmed the effectiveness of the subdivision method, revealing a subdivision error of less than 0.6”.

17 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YHYao Huang
Yao Huang
SCShuangliang Che
Shuangliang Che
GZGang Zheng
Gang Zheng
WZWeibin Zhu
Weibin Zhu
YZYi Zhou
Yi Zhou
ZXZi Xue
Zi Xue
Angle is an important physical quantity in International Systems of Units (SI). The precise measurement of an angle is of great significance for scientific research and production. The circular grating is a widely used angle measurement sensor because of its large range and high resolution. Subdivision is the key part of grating measurement to ensure high resolution. In order to guarantee the subdivision function, we propose an adaptive filter to suppress the noises in the moiré signals of the circular grating. The principle of subdivision is introduced and the arc-tangent subdivision method mapping the phase of the moiré signals into the displacement is adopted. The influence of noises on subdivision results is analyzed by building the error model of the moiré signals. A detailed description of the adapted filter, which is composed of a linear prediction filter and the least mean square (LMS) adaptive algorithm, is provided herein. The structure of the adapted filter is optimized with a symmetrical structure and the hardware resources are reduced by about 1/3. Finally, evaluation tests are performed with a calibration platform for positioning the accuracy of a turntable and a laboratory-made field-programmable gate array (FPGA) circuit. The results confirmed that the adaptive filter proposed in this article can filter out random noises more effectively than the conventional finite impulse response (FIR) filter with the same order, revealing a phase error fluctuates within [−0.012, +0.003 rad]. The positioning accuracy of the turntable with a laboratory-made circuit using an adaptive filter is better than 0.8.

26 August 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZWei Zou
Wei Zou
YHYao Huang
Yao Huang
HLHu Lin
Hu Lin
ZXZi Xue
Zi Xue
Ring laser gyroscope is one of the most important equipment in high-precision strapdown inertial navigation systems, and has been widely used in the field of navigation. At present, there is little research on the application of ring laser gyroscope on the angle error measurement of sub-arc-second in the metrology field, and it has not been officially used as the metrology standard instrument. Aiming at the inaccurate measurement of ring laser gyroscope in metrology due to zero position drift and non-coplanar installation, a non-contact high-precision angle measurement error measurement method is proposed in this paper. Firstly, the original scale factor is calculated on the standard rotating device to avoid re-calculated on the measured device and solve the traceability problem. Secondly, the influence of the installation error between the turntable and the laser gyroscope goniometer on the angle measurement error is analyzed, and the compensation method of angle measurement error in the online measurement of the laser gyroscope is proposed. Finally, the feasibility of online metrology of ring laser gyroscope is verified by experiments, and the measurement uncertainty is estimated. The online measurement results show that compared with the photoelectric autocollimator (measurement uncertainty is U = 0.07ʺ ( k = 2), the angle measurement error of the ring laser gyroscope goniometer in multi-axis turntable is ±0.4ʺ, and the measurement uncertainty is U = 0.36ʺ ( k = 2).

21 July 2025 in Measurement
Verified
Journal Article
Closed access
KSKairu Shao
Kairu Shao
WZWeibin Zhu
Weibin Zhu
YHYao Huang
Yao Huang
ZXZi Xue
Zi Xue
JZJin Zhu
Jin Zhu
ZYZhaoqin Yin
Zhaoqin Yin

16 November 2023 in Photonics
Verified
Journal Article
Open access
PDF file
YHYao Huang
Yao Huang
SCShuangliang Che
Shuangliang Che
WZWeibin Zhu
Weibin Zhu
CMCheng Ma
Cheng Ma
YZYi Zhou
Yi Zhou
ZXZi Xue
Zi Xue
In view of the limitations of the existing eccentricity error separation method of the rotary table, an eccentricity error separation method based on the phase feature of the moiré signal of a single reading head is proposed herein. A grating pair transmission model is established based on the analysis of the principle of the rotary table; thereby, the influence of eccentricity error on the phase feature of the moiré signal in the rotation course of the rotary table is clarified, and the corresponding model between the phase feature spectral components and the eccentricity error is established. The verification experiments of the proposed method are carried out based on the laboratory-made circuit system. After verifying the accuracy of the data acquisition of the laboratory-made circuit board, the verification experiments of the eccentricity error separation effect of the proposed method are carried out. The experimental data are compared with those of the traditional method, and the results show that the error between the two methods is 2.34 μm, while the relative error is 2.3%.

26 August 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WZWei Zou
Wei Zou
YHYao Huang
Yao Huang
HLHu Lin
Hu Lin
ZXZi Xue
Zi Xue
This paper gives a new application of laser gyro in the field of metrology, that is, the perpendicularity measurement method between two axes of multi-axis turntables based on single-axis laser gyro goniometer. This method skillfully establishes different coordinate frames on the turntable and uses the projection variation of the sensitive axis of the laser gyro in the coordinate frame to solve the perpendicularity. This method can also accurately solve the misalignment angle of the laser gyro goniometer at the same time. It is suitable for online measurement of perpendicularity between the axes of multi-axis turntables in fields such as CNC machine tools, robots, flight simulation, and inertial testing. This method has simple equipment installation, convenient measurement operation, high measurement accuracy (the measurement uncertainty is U = 0.23′′ (k = 2), and fully utilizes the dynamic characteristics of the laser gyro goniometer.