30 April 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Pulsewidth modulation current source converter (CSC)-based drive is one of the widely used drives in high-power (megawatt level) medium-voltage (MV) (2.3-6.6 kV) applications. The switching frequency of the MV CSC is limited to around 500 Hz to satisfy thermal requirement and reduce switching loss. Under such a condition, the overall performance of the used modulation scheme, especially its harmonics performance, is an important consideration for CSC-based drives. To date, a couple of modulation schemes have been proposed for MV CSCs, and this paper aims to present an overview of these modulation schemes. Traditional modulation schemes are reviewed, the recent advances are illustrated and analyzed, and the challenges and trends are discussed.
27 October 2021 in IEEE Transactions on Power Electronics
In this article, a modular current-fed high-frequency transformer isolated matrix converters (CF-HFT-MC) based wind energy conversion system (WECS) is proposed. The CF-HFT-MC module utilizes the high-frequency transformer instead of the line-frequency input transformer, and eliminates the bulky and vulnerable electrolytic capacitors in the WECS. Therefore, the power density, reliability and efficiency of WECS can be increased. Moreover, single-stage power conversion and soft-switching can be achieved in the CF-HFT-MC modules, which can reduce the losses of the system. With the function of electric isolation, the wind turbines can be connected in series through the proposed CF-HFT-MC modules. Thus, the total dc output voltage is increased, which enables the offshore wind farm to be integrated to the current-source-converters based HVdc transmission directly. The modulation, control scheme and power sharing method are analyzed and designed for the proposed CF-HFT-MC based WECS in this article. Both the simulations and the experiments are given to verify the effectiveness of the proposed system.
20 August 2018 in IEEE Transactions on Power Electronics
Previous research on the series-connected PWM current source converter-based offshore wind energy conversion system is conduct-ed without considering the effects of the independent control of offshore converters and the cables connected between offshore converters and between offshore and onshore converters. In the present work, a further study on the system is conducted taking these factors into consideration. First, the equivalent circuit of the system is derived, based on which two items are selected to evaluate the performance of the system, one is the DC-link current and the other the DC-link voltage. Second, both DC-link current and DC-link voltage are derived and analyzed that the worst case and its condition are quantitatively and qualitatively defined. Third, the performance of the system with DC filters is investigated. Finally, both simulation and lab-scaled experiments are provided
1 September 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Current source converter (CSC)-based wind energy conversion systems (WECSs) are recently gaining increasingly attention due to its reliable short-circuit protection. However, all existing CSC-based configurations are proposed for medium-voltage (MV) (3-4 kV) wind turbine systems, but not for low-voltage (LV) (690 V) systems which are dominating the market of WECS. The biggest challenge for using CSCs in LV systems is no proper switching devices in the market. This paper proposes a new configuration, where a proven modular LV voltage source converter is used as the generator-side converter to be compatible with an MV CSC. By such a design, MV CSCs are successfully used in LV systems with all advantages being inherited. In addition, this configuration features high reliability and reduced size and weight, thanks to the adoption of the modular converter. The performance of the configuration under normal and fault conditions are investigated. Apart from fulfilling traditional control objectives in WECS, a current balancing control is added to ensure safe operation. Additionally, limits and constraints of the configuration using in practice are discussed. Finally, simulation and down-scaled experimental results are presented.
2 June 2017 in IEEE Transactions on Industrial Electronics
In current source inverter (CSI)-based series-connected configurations, recently proposed for offshore wind energy conversion systems, a number of medium-voltage CSIs are connected in series to form a centralized dc/ac inverter to transfer offshore wind power to the grid. In previous studies, the series-connected CSIs are controlled based on assumptions that all CSIs are ideal and identical and the power is evenly distributed among them. However, in practice, such assumptions are invalid as tolerance exists. This study therefore works on the investigation of power distribution among series-connected CSIs considering the tolerance. First, the possible imbalance of power among CSIs is unveiled, analyzed, and quantitatively defined. Second, a combined control scheme is proposed, based on which both conventional control objectives, which are dc-link current control and power factor control, and an equal power distribution among CSIs are ensured simultaneously. Finally, simulations and lab-scaled experiments are provided.
3 October 2022 in IEEE Transactions on Power Electronics
The power converters currently used in high-power (a few megawatts) medium-voltage PV systems require the use of a line-frequency transformer (LFT), which is bulky and costly. To solve this issue, cascaded H-bridge converter and modular multilevel converter based converters were proposed and investigated in the literature. They can eliminate the LFT but suffer several technical challenges, one of which, for example, is a power imbalance. To address these challenges, extra efforts, such as modified converters, modulations, and controls, are needed. Such extras burden the original converters and introduce new challenges. Therefore, a new power converter is proposed in this work. It eliminates the LFT without these challenges faced by the existing solutions. In addition, it features reliable short-circuit protection, high scalability, simple, and well-proven converters. The operation principle is introduced, and the control scheme is developed. The performance is investigated and verified based on both simulations and lab-scaled experiments.