9 May 2022 in IEEE Transactions on Industrial Electronics
Wireless power transfer system has played an important role in rail transit, industrial production, and daily life. This article proposes a wireless power transfer permanent-magnet synchronous motor (WPT-PMSM) drive system based on the matrix converter (MC). The direct conversion of low-frequency ac and high-frequency ac is realized without dc link by using MC. The dual LCC compensation network is designed for better performance. In addition, a new control method has been proposed for the proposed WPT-PMSM drive to operate stably. In particular, the bidirectional power flow is achieved with the proposed WTP-PMSM drive and related control scheme. Through the mathematical modeling, the coordinated control of power converters on both sides of the coupling coil is achieved and the reactive power of the LCC compensation network is eliminated. The experiments on a 1 kW and 85 kHz laboratory prototype of the WPT-PMSM drive are presented to verify the feasibility and effectiveness of the proposed system.
24 June 2020 in IEEE Transactions on Power Electronics
The SiC devices have attracted more and more attention due to the capability of withstanding higher blocking voltage, higher switching frequency, and higher temperature. However, challenges for SiC devices applied in voltage-source-inverter (VSI) fed motor drives such as electromagnetic interference (EMI) issues and limited over-current capability still limit the further application of SiC devices. In this paper, a novel SiC devices based zero-voltage-switching (ZVS) current-source-inverter (CSI) is proposed for permanent-magnet synchronous motor (PMSM) drive. The key is to propose an auxiliary resonant circuit, which achieves ZVS conditions for all switches in power circuits and reduces the dv/dt of high speed SiC devices. The resonant capacitor in the auxiliary circuit can clamp overvoltage caused by possible open-circuit faults. To further reduce the EMI, the random switching frequency PWM (RSFPWM) is designed for the proposed CSI motor drive. The system configuration, working principle, circuit design and control schemes are described in detail. Both simulations and experiments are presented to verify the effectiveness of the proposed ZVS CSI fed PMSM drive system.
12 January 2021 in IEEE Transactions on Power Electronics
This letter proposes a four-leg current-source inverter (CSI) fed three-phase motor drive. Different from the previous four-leg CSI inverter, the proposed configuration introduces the fourth leg in CSI, which connects to the neutral point of the motor through an extra output filter capacitor. Therefore, the proposed configuration can not only reduce the common-mode voltage (CMV) under the normal condition, but also provide the fault-tolerant operation ability under open-circuit faults in windings and switches. The dedicated space vector modulation (SVM) strategies have been designed. Compared with prior research on CMV reduction, the four-leg method has the full range of modulation index and will not increase any harmonics in the currents. Meanwhile, the fault-tolerant ability is offered, which can further enhance the reliability of the motor drive. A laboratory prototype has been built to experimentally verify the effectiveness of the proposed motor drive topology and the control schemes.
11 November 2019 in IEEE Transactions on Power Electronics
In this paper, the switching strategy and the remedial control scheme are studied for the cascaded current-source converters (CSCs) fed dual three-phase permanent-magnet synchronous motor (PMSM) variable-speed drives. An optimized space vector modulation (SVM) strategy is proposed to reduce the DC-link current ripple for the proposed drives system. In particular, this switching strategy can work effectively for motor drives under low speed with low back-EMF, where there exists a large voltage difference between peak voltage values on the grid side and the motor side. Apart from that, a hybrid fault-tolerant control scheme is also designed for the open-phase fault in dual three-phase PMSM drives system, aiming at achieving small DC-link current ripple and torque ripple, low copper loss and machine-friendly waveform quality. With the proposed optimized SVM and the hybrid fault-tolerant control strategy, the DC-link current ripple of the cascaded CSCs system can be effectively reduced and good operational performance can be obtained under both normal operation condition and open-phase fault condition. Experimental results are provided to verify the effectiveness of the proposed methods.
27 October 2021 in IEEE Transactions on Power Electronics
In this article, a modular current-fed high-frequency transformer isolated matrix converters (CF-HFT-MC) based wind energy conversion system (WECS) is proposed. The CF-HFT-MC module utilizes the high-frequency transformer instead of the line-frequency input transformer, and eliminates the bulky and vulnerable electrolytic capacitors in the WECS. Therefore, the power density, reliability and efficiency of WECS can be increased. Moreover, single-stage power conversion and soft-switching can be achieved in the CF-HFT-MC modules, which can reduce the losses of the system. With the function of electric isolation, the wind turbines can be connected in series through the proposed CF-HFT-MC modules. Thus, the total dc output voltage is increased, which enables the offshore wind farm to be integrated to the current-source-converters based HVdc transmission directly. The modulation, control scheme and power sharing method are analyzed and designed for the proposed CF-HFT-MC based WECS in this article. Both the simulations and the experiments are given to verify the effectiveness of the proposed system.
28 April 2020 in IEEE Transactions on Industrial Electronics