In this study, the visualization of the flow structure around a circular cylinder was investigated with dye injection experiments. The experiments were carried out in the closed-circuit open water channel in Osmaniye Korkut Ata University. Experiments have been studied on a circular cylinder at different rotational speeds. Experiments were carried out at Re = 1000 according to cylinder diameter and free stream velocity. In the study, with the increase of the rotation speed, an acceleration layer occurs between the fluid velocity in the cylinder wake in the flow direction and the flow from the circumference of the cylinder and the speed of rotation. This situation caused the complete disappearance of the vortex ruptures in the flow direction and the emergence of Kelvin Helmhotz fluctuations. As a result of the study, it is seen that the flow control is insufficient at low rotational speeds, but the flow can be controllable at high rotational speeds.
Küp şeklindeki cisimlerin birbiri ile konumlandırılması cisimlerin etrafındaki akış yapısından kaynaklanan akış etkileri açısından önemlidir. Cisimlerin yerleşimi faydalı rüzgâr akımı yaratabileceği gibi istenmeyen rüzgâr akımı meydan getirerek cisimlerde yapısal titreşimler ve gürültü gibi istenmeyen durumları da meydana getirebilmektedir. Bu çalışmada akrilik malzemeden, 75x75mm boyutlarında imal edilen küp cisim modelleri, aralarında farklı açıklık oranlarında (D/h = 0.5, 1 ve 2) olacak şekilde konumlandırılmıştır. D küpler arasındaki mesafeyi, h küpün kenar uzunluğunu ifade etmektedir. Kullanılan modellerin karakteristik çapına (h) ve akış hızına (V) bağlı olarak deneyler Reynolds sayısı, Re=26000’de gerçekleştirilmiştir. Parçacık Görüntüleme Hız Ölçüm Tekniği (PIV) kullanılarak anlık olarak elde edilen hız vektörleri ile anlık girdap, akım çizgisi gibi bileşenler hesaplanmış ve hesaplanan anlık verilerle de zaman ortalama hız, girdap ve türbülans istatistikleri belirlenmiştir. Çalışma sonucunda, ayrılmış akış bölgesinin D/h oranının artması ile daha geniş bir alana yayıldığı görülmektedir. D/h oranının artması ile hız bileşeninin dalgalanmalarının azaldığı, modeller arasındaki D/h oranının azalması ile iki model arasında kalan bölgede akış hızının arttığı tespit edilmiştir.
This study investigated experimentally the flow regime with a face shield on a face mannequin placed at different distances (L=50 cm and L=150 cm to source of flow), i.e., perpendicular to the channel or at an angle of 10°, through the PIV (Particle Imaging Velocimetry) method along with the dye experiments, based on which the face shield and dye injector were positioned to conduct the PIV tests. As a result of the experiments, instantaneous velocity vectors and velocity magnitude data were obtained, and the flow structure around the face shield was examined in detail. The study revealed that the flow released through the respiratory tract hit the face and eye area of the mannequin in the experiments performed without using a face shield, yet, with the face shield, the flow that emerged while talking at a close distance was directed from the lower part of the face shield towards the neck and jaw but protected the face and eye area compared to the case without a face shield. It was observed that the flow lost its energy when it first left the flow source, and the velocity vectors were directed down the neck area. Positioning the mannequin at an angle of 10° turned out to be less protective than positioning it perpendicular to the channel, due to the flow being directed from the jaw to the mouth area with the effect of the angle.
Bu çalışmada farklı derece gün bölgelerinde yer alan iki farklı şehirdeki yeşil çatı uygulamasının ısıtma ihtiyacına, çevre emisyonlarına ve yakıt maliyetine etkisi iki farklı iç ortam sıcaklıklarında incelenmiştir. Binanın, ısı yalıtımsız, ısı yalıtımlı ve yeşil çatılı olma durumları için ısıtma ihtiyacı, aylık yakıt maliyeti ve emisyon değerleri belirlenmiştir. Ayrıca ekonomik analiz yapılarak ısı yalıtımı ve yeşil çatı uygulaması ile yatırımın geri ödeme süresi hesaplanmıştır. İç ortam sıcaklığı 19°C olduğu durumda ikinci gün bölgesinde mayıs ve eylül aylarında ısıtma ihtiyacına gerek duyulmazken, iç ortam sıcaklığı 21°C olduğu durumda mayıs ve eylül aylarında ısıtma ihtiyacına gerek duyulmuştur. İç ortam 19°C için birinci gün bölgesi için 15161.80 kgCO2, ikinci gün bölgesi için ise 32484.27 kgCO2’lik, iç ortam sıcaklığının 21°C kabul edilmesi durumu için birinci gün bölgesi için 19344.34 kgCO2, ikinci gün bölgesi için ise ısı yalıtımsız duruma göre 36246.31 kgCO2’lik bir azaltma gerçekleştirilmiştir.