15 February 2024 in BMC Oral Health
Today, resin materials are used in the restoration of permanent and deciduous teeth or as fissure sealants. The materials can contain different types of monomers (Bis-GMA, UDMA, TEGDMA). These monomers can be released into the oral cavity after polymerization. Residual monomers released from resin-containing restorative materials after polymerization have been reported to have negative effects on mechanical properties. The aim of our study is to evaluate the amount of residual monomers released after polymerization of different flowable composite resin materials using two different modes of LED light source. Composite disc samples (8 mm diameter/2 mm depth) prepared for each material group were polymerized using two different modes of the LED light device (Standard mode and extra power mode). HPLC (High Performance Liquid Chromatography) device was used to measure the amount of residual monomer release at 1 h, 1 day, 3 days and 7 days periods. Pairwise comparison of the differences between the materials was performed by Post-hoc test. For each residual monomer, the Kruskal Wallis test was used to analyze the difference between the materials in standard mode and the difference between the materials in extra power mode. According to the results of the study; Grandio flow flowable composite showed the highest release of TEGDMA and Bis-GMA while SDR® Flow flowable composite showed the lowest release of TEGDMA, Bis-GMA and UDMA. For all materials, the extra power mode resulted in more residual monomer release. TEGDMA and Bis-GMA release was detected in all tested flowable composites at all time periods.
23 February 2024 in BMC Oral Health
Background: The aim of this study is to evaluate the stress distributions of a primary molar tooth restored with a stainless steel crown (SSC) using resin and glass ionomer luting cements by Finite Element Analysis (FEA). Methods: Original DICOM data of a primary molar was used to create a 3D model. One model was prepared as a tooth model with SSC. A 30 μm cement layer was used in model. Two different luting cements were tested in the study: self-cure adhesive resin cement, and glass ionomer cement. Vertical and oblique loads of 330 N were applied to simulate maximum bite force and lateral forces in the occlusal contact areas of the models. Maximum von Mises stress values in the models were evaluated as MPa. Results: The maximum von Mises stress value was observed in the force application and general occlusal contact areas for all models. The maximum von Mises stress values were higher in the tooth model with SSC using self-cure adhesive resin cement (478.09 MPa and 214.62 MPa) than in the tooth model with SSC using glass ionomer cement (220.06 MPa and 198.72 MPa) in both vertical and oblique loading, respectively. Conclusions: Depending on the magnitude of the bite force on the SSC, fracture of the luting cement materials could occur if the stress exceeds the endurance limit of the luting cement. Cementation with glass ionomer cement may help to reduce stress levels in SSC restorations of primary molars in children.
30 September 2025 in Kapadokya Üniversitesi
Amaç: Kanser vücuttaki bazı hücrelerin kontrolsüz olarak çoğalması nedeniyle oluşan ve her yıl yüksek oranda ölüm ile sonuçlanan hastalıkların başında gelmektedir. Kanser te-davilerinde yüksek sitotoksisite nedeniyle birçok yan etki görülmektedir. Mukozitis, diş etle-rinde kanama, ağız kuruluğu, ağrı, tat kaybı ve değişikliği oral komplikasyonlardan başlıca-larıdırBu çalışmanın amacı Tıp Fakültesi Hematoloji Onkoloji Servisinde tedavi gören 3-18 yaş arası çocuk hastaların ağız içi bulgularının ve oral hijyen alışkanlıklarının değerlendiril-mesidir. Malzeme ve Yöntemler: Hematoloji Onkoloji Servisinde tedavi gören 3 ile 18 yaş ara-sında 50 çocuk hasta ebeveynlerinin eşliğinde muayene edildi. Hastaların ebeveynlerinden bilgilendirilmiş onam formu alındı. Hastaların ebeveyn eşliğinde hastalığı, kemotera-pi/radyoterapi durumu, tedavi süresi, beslenme şekli, diyet ve ağız bakım alışkanlıkları sor-gulandı. Hastaların DMFT indeksleri ölçüldü. Çocuklarda ağız kuruluğu, tat kaybı ve oral mukozit varlığı kayıt altına alındı. Bulgular: Çalışmamıza katılan hastaların sosyo-demografik verileri incelendiğinde yaş ortalamaları 9,6 ± 4,45 (min 3- max 18)’tir ve %70’i (n=35) erkek, %30’u (n=15) kız çocuk-tur. DMFT indekslerinin ortalaması 4,1 ± 3,46 (min 0- max 13)’dır. Hastaların aldıkları tanılar değerlendirildiğinde en sık akut lenfoblastik lösemi (ALL) (n=25) tümörü nedeniyle hastane-de tedavi altında oldukları belirlenmiştir. Tedaviye bağlı oral yan etkiler incelendiğinde %24’ünün (n=12) tat kaybı yaşadığını, %34’ünün (n=17) oral mukozit olduğu, %42’sinin (n=21) de ağız kuruluğu şikayetleri olduğu belirlenmiştir. Yapılan analiz sonuçlarına göre tedavi şekli ile ağız kuruluğu arasında (p=,009) ve tedavi şekli ile tat kaybı arasında istatistiksel olarak anlamlı bir ilişki bulunmuştur (p=,027). Sonuç: Kanser ve kanser tedavisinde uygulanan antineoplastik protokoller hastanın ağız sağlığı üzerinde olumsuz etkilere sebep olmakta ve bu da hastanın yaşamını oldukça zorlaştırmaktadır. Bir çocuk diş hekiminin tedavi öncesi ve tedavi sırasındaki müdahalesi ile etkili bir ağız bakımı sağlanabilir ve palyatif bakımda önemli bir fark yaratılabilir. Tedavi sü-resince ağız sağlığının korunmasında çocuk doktoru, çocuk diş hekimi ve onkolog iş birliği ile multidisipliner çalışma oldukça büyük önem taşımaktadır.
30 November 2022 in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
Objective: The aim of this study is to evaluate the effect of polymerization in different light power modes on the radiopacity of six different composite resins (Filtek Z250, Xtrafil, Tetric N Ceram, SureFil SDR Flow, Nova Compo HF, Grandio Flow).Methods: Plexiglass molds (8 mm diameter, 2 mm thickness) were used for the preparation of the samples. Totally ten samples were formed for each composite resin (standard mode; n=5 and extra power mode; n=5). A 2-mm-thickness buccolingual section was obtained from the extracted premolar tooth for enamel and dentin samples. To evaluate the relationship between the density of the samples and tooth structure, an Al step wedge was used as a reference. The mean gray values of each composite resin, enamel, dentin, and Al step wedge were calculated with an image analysis program. Data were analyzed with an independent sample t-test, one-way ANOVA, and Tukey HSD test.Results: All tested composites met ISO standards. Even if the radiopacity values of tested composites changed according to the light power mode, this change was found to be statistically significant only in SureFil SDR Flow (p=0.037). The difference between the radiopacity values of tested composites in both standard power and extra power mode was statistically significant (p<0.01). The highest radiopacity values were produced by the bulk-fill composites in both standard and extra power modes.Conclusion: In this study, all tested composites were found to have sufficient radiopacity for restorations according to the criteria set by the ISO.
25 June 2025 in İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi
Sharps injuries are among the leading occupational accidents and risks to which healthcare workers are exposed. Our study aimed to evaluate the level of awareness and approaches of Ordu University Faculty of Dentistry students about the safe use of sharps during their education and throughout their professional lives. The study included 189 students who voluntarily agreed to participate in the study among the 4th and 5th grade students studying at Ordu University Faculty of Dentistry. Demographic information and multiple-choice questionnaire questions were asked to measure the level of knowledge and attitudes of the students toward the safe use of materials. All data of 189 students [147 female (75%) and 42 male (25%)] were included in the study. It was determined that the most common cause of injury was 'glass in the hand as a result of a broken light bulb'. The most common intervention was 'cleaning with antiseptic' with 52%. Dental students are at serious risk of sharps injuries during their clinical practice training. To minimize these risks, faculties should take the necessary precautions by health quality policies.
31 May 2025 in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
Objective: This study aimed to compare the removability of fractured nickel-titanium rotary instruments with different working principles in the middle and coronal thirds of the canal using ultrasonic tips and the BTR pen. Method: Thirty-two mandibular molars were selected from recently extracted teeth that met the inclusion criteria. Teeth had to have a closed apex, no root caries, anomalies, fractures, cracks, or signs of internal or external resorption. The mesiobuccal roots were intentionally fractured, and the root inclination was confirmed to be ≤20° using Schneider's method. Teeth with a higher inclination angle were excluded. Access cavities were opened traditionally to allow direct canal access, and apical patency was verified with #10 K files. Canal lengths were measured, and teeth were embedded in acrylic blocks for easier handling. The teeth were divided into four study groups (n=8) based on the working principle of the instrument and the location of the fractured instrument (coronal or middle third). NiTi instruments with the same taper (0.6) and heat treatment (blue) were selected. A 4 mm mark was made on each file, and files were thinned to half their thickness at the designated breaking point using a diamond bur. A stage platform was created with Gates Glidden burs to improve the visibility of the broken instruments. After creating the platform, dentin around the broken files was removed by 2 mm with ultrasonic tips, and the broken pieces were extracted using a BTR Pen with a 0.3 mm thin wire loop. Results: When analyzed by working principle, the removal time for fractured instruments in the middle third was significantly higher (p=0.0001). Within the coronal third, the removal time for reciprocal files was significantly longer (p=0.021). Similarly, in the middle third, the removal time for reciprocal files was statistically longer (p=0.004). Conclusion: The BTR Pen was effective for both rotary file systems. The location of the fractured instrument influenced the removal time, with faster results in the coronal third due to better access and visibility. Additionally, the type of fractured NiTi rotary instrument also impacted the time required for successful removal, with rotary instruments in the middle third taking significantly longer.