Andres Diaz-Pinto

Andres Diaz-Pinto

Auto-generated profile, based on publicly available information

Andres Diaz-Pinto

School of Biomedical Engineering & Imaging Sciences, King's College London, St Thomas' Campus, St Thomas' Hospital, Westminster Bridge Road, London SE1 7EH, UK

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Medical Image Analysis
Verified
Journal Article
Closed access
JOJosé Ignacio Orlando
José Ignacio Orlando
HFHuazhu Fu
Huazhu Fu
JBJoao Barbosa-Breda
Joao Barbosa-Breda
KKKarel van Keer
Karel van Keer
DBDeepti R. Bathula
Deepti R. Bathula
HBHrvoje Bogunović
Hrvoje Bogunović

20 March 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ADAndres Diaz-Pinto
Andres Diaz-Pinto
SMSandra Morales
Sandra Morales
VNValery Naranjo
Valery Naranjo
TKThomas Köhler
Thomas Köhler
JMJose M. Mossi
Jose M. Mossi
ANAmparo Navea
Amparo Navea
Most current algorithms for automatic glaucoma assessment using fundus images rely on handcrafted features based on segmentation, which are affected by the performance of the chosen segmentation method and the extracted features. Among other characteristics, convolutional neural networks (CNNs) are known because of their ability to learn highly discriminative features from raw pixel intensities. In this paper, we employed five different ImageNet-trained models (VGG16, VGG19, InceptionV3, ResNet50 and Xception) for automatic glaucoma assessment using fundus images. Results from an extensive validation using cross-validation and cross-testing strategies were compared with previous works in the literature. Using five public databases (1707 images), an average AUC of 0.9605 with a 95% confidence interval of 95.92–97.07%, an average specificity of 0.8580 and an average sensitivity of 0.9346 were obtained after using the Xception architecture, significantly improving the performance of other state-of-the-art works. Moreover, a new clinical database, ACRIMA, has been made publicly available, containing 705 labelled images. It is composed of 396 glaucomatous images and 309 normal images, which means, the largest public database for glaucoma diagnosis. The high specificity and sensitivity obtained from the proposed approach are supported by an extensive validation using not only the cross-validation strategy but also the cross-testing validation on, to the best of the authors’ knowledge, all publicly available glaucoma-labelled databases. These results suggest that using ImageNet-trained models is a robust alternative for automatic glaucoma screening system. All images, CNN weights and software used to fine-tune and test the five CNNs are publicly available, which could be used as a testbed for further comparisons.

7 March 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ADAndres Diaz-Pinto
Andres Diaz-Pinto
ACAdriáan Colomer
Adriáan Colomer
VNValery Naranjo
Valery Naranjo
SMSandra Morales
Sandra Morales
Yanwu XuYanwu Xu
Yanwu Xu
Attilio FrangiAttilio Frangi
Attilio Frangi
Recent works show that Generative Adversarial Networks (GANs) can be successfully applied to image synthesis and semi-supervised learning, where, given a small labelled database and a large unlabelled database, the goal is to train a powerful classi?er. In this paper, we trained a retinal image synthesizer and a semi-supervised learning method for automatic glaucoma assessment using an adversarial model on a small glaucoma-labelled and large unlabelled database. Various studies have shown that glaucoma can be monitored by analyzing the optic disc and its surroundings, for that reason the images used in this work were automatically cropped around the optic disc. The novelty of this work is to propose a new retinal image synthesizer and a semi-supervised learning method for glaucoma assessment based on the Deep Convolutional Generative Adversarial Networks (DCGAN). In addition, and to the best of the authors’ knowledge, this system is trained on an unprecedented number of publicly available images (86926 images). This system, hence, is not only able to generate images synthetically but to provide labels automatically. Synthetic images were qualitatively evaluated using t-SNE plots of features associated with the images and their anatomical consistency were estimated by measuring the proportion of pixels corresponding to the anatomical structures around the optic disc. The resulting image synthesizer is able to generate realistic (cropped) retinal images and, subsequently, the glaucoma classi?er is able to classify them into glaucomatous and normal with high accuracy (AUC= 0.9017). The obtained retinal image synthesizer and the glaucoma classi?er could be used then to generate an unlimited number of cropped retinal images with glaucoma labels.

15 May 2024 in Medical Image Analysis
Verified
Journal Article
Closed access
ADAndres Diaz-Pinto
Andres Diaz-Pinto
SASachidanand Alle
Sachidanand Alle
VNVishwesh Nath
Vishwesh Nath
YTYucheng Tang
Yucheng Tang
AIAlvin Ihsani
Alvin Ihsani
MCM. Jorge Cardoso
M. Jorge Cardoso

25 January 2022 in Nature Machine Intelligence
Verified
Journal Article
Closed access
PDF file
ADAndres Diaz-Pinto
Andres Diaz-Pinto
NRNishant Ravikumar
Nishant Ravikumar
RARahman Attar
Rahman Attar
ASAvan Suinesiaputra
Avan Suinesiaputra
YZYitian Zhao
Yitian Zhao
Attilio FrangiAttilio Frangi
Attilio Frangi

14 December 2020 in Progress in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
XCXiang Chen
Xiang Chen
ADAndres Diaz-Pinto
Andres Diaz-Pinto
NRNishant Ravikumar
Nishant Ravikumar
Attilio FrangiAttilio Frangi
Attilio Frangi