1 September 2016 in Physica Medica
This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation.
24 March 2015 in Radiation Protection Dosimetry
The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y−1, averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y−1. This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y−1. Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y−1. It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown.
15 December 2014 in Radiation Protection Dosimetry
The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y−1 averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in order to have a good estimate of the eye lens dose during interventional procedures. Measurements were performed with an X-ray system Philips Allura FD-10, using a PMMA phantom to simulate the patient scattered radiation and a Rando phantom to simulate the cardiologist. Thermoluminescence (TL) whole-body and TL eye lens dosemeters together with Philips DoseAware active dosemeters were located on different positions of the Rando phantom to estimate the eye lens dose in typical cardiology procedures. The results show that, for the studied conditions, any of the analysed dosemeter positions are suitable for eye lens dose assessment. However, the centre of the thyroid collar and the left ear position provide a better estimate. Furthermore, in practice, improper use of the ceiling-suspended screen can produce partial protection of some parts of the body, and thus large differences between the measured doses and the actual exposure of the eye could arise if the dosemeter is not situated close to the eye.
9 July 2015 in Radiation Protection Dosimetry
In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements.
18 November 2016 in Journal of Radiological Protection
Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator’s head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator’s head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following: (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes; (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned; (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring.
13 October 2015 in Radiation Protection Dosimetry
Recent studies highlight the fact that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens monitoring could be required for these workers. The recommended operational quantity for monitoring of eye lens exposure is the personal dose equivalent at 3 mm depth Hp(3) (ICRU 51). However, there are no available conversion coefficients in international standards, while in the literature coefficients have only been calculated for monoenergetic beams and for ISO 4037-1 X-ray qualities. The aim of this article is to provide air kerma to Hp(3) conversion coefficients for a cylindrical phantom made of ICRU-4 elements tissue-equivalent material for RQR radiation qualities (IEC-61267) from 40 to 120 kV and for angles of incidence from 0 to 180°, which are characteristic of medical workplace. Analytic calculations using interpolation techniques and Monte Carlo modelling have been compared.