Jean-Christophe Ginefri

Jean-Christophe Ginefri

Auto-generated profile, based on publicly available information

Jean-Christophe Ginefri

Laboratoire d’Imagerie Biomédicale Multimodale Paris Saclay (BioMaps), CEA, CNRS, Inserm, Université Paris-Saclay, Orsay, France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
LNLena Nohava
Lena Nohava
RCRaphaela Czerny
Raphaela Czerny
SRSigrun Roat
Sigrun Roat
MOMichael Obermann
Michael Obermann
AKAndre Kuehne
Andre Kuehne
ELElmar Laistler
Elmar Laistler
Magnetic resonance has become a backbone of medical imaging but suffers from inherently low sensitivity. This can be alleviated by improved radio frequency (RF) coils. Multi-turn multi-gap coaxial coils (MTMG-CCs) introduced in this work are flexible, form-fitting RF coils extending the concept of the single-turn single-gap CC by introducing multiple cable turns and/or gaps. It is demonstrated that this enables free choice of the coil diameter, and thus, optimizing it for the application to a certain anatomical site, while operating at the self-resonance frequency. An equivalent circuit for MTMG-CCs is modeled to predict their resonance frequency. Possible configurations regarding size, number of turns and gaps, and cable types for different B 0 field strengths are calculated. Standard copper wire loop coils (SCs) and flexible CCs made from commercial coaxial cable were fabricated as receive-only coils for 3 T and transmit/receive coils at 7 T with diameters between 4 and 15 cm. Electromagnetic simulations are used to investigate the currents on MTMG-CCs, and demonstrate comparable specific absorption rate of 7 T CCs and SCs. Signal-to-noise ratio (SNR), transmit efficiency, and active detuning performance of CCs were compared in bench tests and MR experiments. For the form-fitted receive-only CCs at 3 T no significant SNR degradation was found as compared to flat SCs on a balloon phantom. Form-fitted transmit/receive CCs at 7 T showed higher transmit efficiency and SNR. MTMG-CCs can be sized to optimize sensitivity, are flexible and lightweight, and could therefore enable the fabrication of wearable coils with improved patient comfort.

27 May 2023 in Investigative Radiology
Verified
Journal Article
Open access
MOMichael Msc Obermann
Michael Msc Obermann
LNLena Nohava
Lena Nohava
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
OSOnisim Soanca
Onisim Soanca
JGJean-Christophe Ginefri
Jean-Christophe Ginefri
ELElmar Laistler
Elmar Laistler
Background: Breast cancer, the most common malignant cancer in women worldwide, is typically diagnosed by x-ray mammography, which is an unpleasant procedure, has low sensitivity in women with dense breasts, and involves ionizing radiation. Breast magnetic resonance imaging (MRI) is the most sensitive imaging modality and works without ionizing radiation, but is currently constrained to the prone imaging position due to suboptimal hardware, therefore hampering the clinical workflow. Objectives: The aim of this work is to improve image quality in breast MRI, to simplify the clinical workflow, shorten measurement time, and achieve consistency in breast shape with other procedures such as ultrasound, surgery, and radiation therapy. Materials and Methods: To this end, we propose “panoramic breast MRI”—an approach combining a wearable radiofrequency coil for 3 T breast MRI (the “BraCoil”), acquisition in the supine position, and a panoramic visualization of the images. We demonstrate the potential of panoramic breast MRI in a pilot study on 12 healthy volunteers and 1 patient, and compare it to the state of the art. Results: With the BraCoil, we demonstrate up to 3-fold signal-to-noise ratio compared with clinical standard coils and acceleration factors up to 6 × 4. Panoramic visualization of supine breast images reduces the number of slices to be viewed by a factor of 2–4. Conclusions: Panoramic breast MRI allows for high-quality diagnostic imaging and facilitated correlation to other diagnostic and interventional procedures. The developed wearable radiofrequency coil in combination with dedicated image processing has the potential to improve patient comfort while enabling more time-efficient breast MRI compared with clinical coils.

1 May 2020 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
ISIsabelle Saniour
Isabelle Saniour
GAGilles Authelet
Gilles Authelet
BBBertrand Baudouy
Bertrand Baudouy
RDRose-Marie Dubuisson
Rose-Marie Dubuisson
LJLaurène Jourdain
Laurène Jourdain
MPMarie Poirier-Quinot
Marie Poirier-Quinot
Small-sized High Temperature Superconducting (HTS) radiofrequency coils are used in a number of micro-magnetic resonance imaging applications and demonstrate a high detection sensitivity that improves the signal-to-noise ratio. However, the use of HTS coils could be limited by the rarity of cryostats that are suitable for the MR environment. This study presents a magnetic resonance (MR)-compatible and easily operated cryogen-free cryostat based on the pulse tube cryocooler technology for the cooling and monitoring of HTS coils below the temperature of liquid nitrogen. This cryostat features a real-time temperature control function that allows the precise frequency adjustment of the HTS coil. The influence of the temperature on the electrical properties, resonance frequency (f0), and quality factor (Q) of the HTS coil was investigated. Temperature control is obtained with an accuracy of over 0.55 K from 60 K to 86 K, and the sensitivity of the system, extracted from the frequency measurement from 60 K to 75 K, is of about 2 kHz/K, allowing a fine retuning (within few Hz, compared to 10 kHz bandwidth) in good agreement with experimental requirements. We demonstrated that the cryostat, which is mainly composed of non-magnetic materials, does not perturb the electromagnetic field in any way. MR images of a 10 × 10 × 15 mm3 liquid phantom were acquired using the HTS coil as a transceiver with a spatial resolution of 100 × 100 × 300 µm3 in less than 20 min under experimental conditions at 1.5 T.

21 November 2019
Verified
Book Chapter
Closed access
PDF file
YTYuanliang Tang
Yuanliang Tang
GGGeneviève Guillot
Geneviève Guillot
JGJean‐Christophe Ginéfri
Jean‐Christophe Ginéfri
MPMarie Poirier‐Quinot
Marie Poirier‐Quinot
LDLuc Darrasse
Luc Darrasse