8 December 2023 in IEEE Transactions on Instrumentation and Measurement
Magnetic particle imaging (MPI) is a tracer-based imaging modality known for its high sensitivity and temporal resolution. It makes the quantitative visualization of the concentration and spatial location of magnetic nanoparticles (MNPs) possible. The x-space method is widely used in MPI for high-speed image reconstruction. In this method, the received signal is mapped directly onto the corresponding spatial position. However, the anisotropic 2D point spread function (PSF) in the x-space method introduces artifacts and blur in the reconstructed images. In this study, an isotropic MPI method, transverse MNP signal-based isotropic imaging (TSI), was developed. It makes isotropic imaging possible in 2D unidirectional Cartesian MPI. Unlike conventional methods that rely on MNP signals registered from the same direction as the excitation, TSI only utilizes MNP signals received perpendicular to the excitation direction. In TSI, the velocity of the time domain signal is first normalized to obtain a “raw-image.” The raw-image is then integrated, differentiated, and added to generate an isotropic MPI image. Because all the operations in TSI are analytical, it preserves the real-time imaging characteristics of the x-space while isotropic imaging is performed. The PSF of TSI was calculated through analytical derivation and the resolution isotropy was validated through simulation and imaging experiments on an in-house-built MPI system. The simulation and experimental results demonstrate that, by improving the isotropy, TSI achieves an approximately 2.5-times increase in resolution in the nonexcitation direction compared with the conventional x-space method. The proposed TSI algorithm does not increase hardware complexity and requires only half the scanning time of the previously proposed multi-channel method. In addition, the transverse MNP signal used in TSI is geometrically decoupled from the excitation magnetic field, eliminating the need for a special compensation design for the receiving coils. This shows promise for future MPI designs with flexible surface coils.
21 November 2025 in IEEE Transactions on Instrumentation and Measurement
The X-space method is a model-based magnetic particle imaging (MPI) reconstruction algorithm known for its simplicity, speed, and robustness. However, its practical application faces two significant challenges. First, feed-through interference contaminates the fundamental frequency of particle signals, disrupting the physical model utilized for X-space reconstruction. Second, the blurring effect caused by the point spread function (PSF) results in lower resolution in the reconstructed X-space images. In this study, we propose a comprehensive strategy to address these issues and achieve high-resolution images reconstruction. This strategy integrates a compact adaptive-compensation algorithm module implemented on an FPGA, which effectively suppresses feed-through interference and acquires high signal-to-noise ratio (SNR) magnetic particle signals, thereby optimizing X-space reconstruction images. Additionally, by employing the X-space reconstruction physical model as the objective function, we introduce a spatially regularized iterative deconvolution (SRID) method based on an optimization model. This approach enhances the resolution of MPI images through the iterative estimation of the point spread function (IE-PSF) combined with the SRID approach. We conducted numerical and phantom experiments to validate the feasibility of the proposed comprehensive strategy. The results demonstrate that the strategy achieves an MPI image spatial resolution superior to 1 mm under a gradient of 1.25 mT/mm, providing a fourfold enhancement in spatial resolution compared to the conventional X-space method.