8 December 2023 in IEEE Transactions on Instrumentation and Measurement
Magnetic particle imaging (MPI) is a tracer-based imaging modality known for its high sensitivity and temporal resolution. It makes the quantitative visualization of the concentration and spatial location of magnetic nanoparticles (MNPs) possible. The x-space method is widely used in MPI for high-speed image reconstruction. In this method, the received signal is mapped directly onto the corresponding spatial position. However, the anisotropic 2D point spread function (PSF) in the x-space method introduces artifacts and blur in the reconstructed images. In this study, an isotropic MPI method, transverse MNP signal-based isotropic imaging (TSI), was developed. It makes isotropic imaging possible in 2D unidirectional Cartesian MPI. Unlike conventional methods that rely on MNP signals registered from the same direction as the excitation, TSI only utilizes MNP signals received perpendicular to the excitation direction. In TSI, the velocity of the time domain signal is first normalized to obtain a “raw-image.” The raw-image is then integrated, differentiated, and added to generate an isotropic MPI image. Because all the operations in TSI are analytical, it preserves the real-time imaging characteristics of the x-space while isotropic imaging is performed. The PSF of TSI was calculated through analytical derivation and the resolution isotropy was validated through simulation and imaging experiments on an in-house-built MPI system. The simulation and experimental results demonstrate that, by improving the isotropy, TSI achieves an approximately 2.5-times increase in resolution in the nonexcitation direction compared with the conventional x-space method. The proposed TSI algorithm does not increase hardware complexity and requires only half the scanning time of the previously proposed multi-channel method. In addition, the transverse MNP signal used in TSI is geometrically decoupled from the excitation magnetic field, eliminating the need for a special compensation design for the receiving coils. This shows promise for future MPI designs with flexible surface coils.
1 August 2025 in Science Advances
Magnetic particle imaging (MPI) enables real-time, sensitive, and quantitative visualization of tracer distribution, augmenting the capability of in vivo imaging technologies. Previous MPI tracer research has predominantly focused on superparamagnetic nanoparticles, whose suboptimal sigmoidal magnetization curves limit their spatial resolution. Here, we introduce the magnetically induced magnetosome chain (MAGiC), a superferromagnetic MPI tracer, demonstrating a 25-fold improvement in resolution in the excitation direction and an order of magnitude improvement in signal intensity compared to the commercial tracer VivoTrax+. Under a gradient field of 4 tesla per meter, the resolution in the excitation direction reached 80 micrometers. Furthermore, MAGiC can be accurately manipulated using magnetic fields, making it an MPI-trackable microrobot. We have elucidated the mechanisms underlying MAGiC’s superior performance and validated its effectiveness in vitro and in vivo. As a high-performance MPI tracer and microrobot, MAGiC holds tremendous potential for various applications, such as cell tracking, image-guided drug delivery, and therapeutic interventions.
20 November 2024 in IEEE Transactions on Computational Imaging
Spatial resolution is one of the most critical indicators for magnetic particle imaging (MPI). Due to factors such as relaxation effects and suboptimal magnetization response, MPI has not yet reached the promised spatial resolution. Pulsed MPI is a method that enables MPI to achieve the resolution predicted by the Langevin function, which thereby enables larger magnetic particles (MNPs) to enhance resolution. To further exceed this resolution, we propose a relaxation-based super-resolution method which leverages the principle that MNPs at different positions exhibit varying relaxation times due to the different DC fields provided by the gradient field. This principle allows the super-resolution method to extract signals from the center of the field free region (FFR) to enhance spatial resolution. The super-resolution method first truncates the exponential decay signal during the plateau phase of the excitation field. Then, the truncated signals are decomposed based on their relaxation times. Finally, signals from the center position of the FFR are retained, and signals from the periphery of the FFR are discarded. Using this retained signal for reconstruction results in a higher spatial resolution. We validate this method via both simulation and experimental measurements. The results indicate that, compared with sinusoidal MPI and pulsed MPI without super-resolution, the super-resolution method has two-fold improvement in resolution.