Byoung-Kyong Min

Byoung-Kyong Min

Auto-generated profile, based on publicly available information

Byoung-Kyong Min

Department of Brain and Cognitive Engineering, Korea University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in NeuroImage
Verified
Journal Article
Closed access
SYSeung-Schik Yoo
Seung-Schik Yoo
ABAlexander Bystritsky
Alexander Bystritsky
JLJong-Hwan Lee
Jong-Hwan Lee
YZYongzhi Zhang
Yongzhi Zhang
KFKrisztina Fischer
Krisztina Fischer
FJFerenc A. Jolesz
Ferenc A. Jolesz

1 July 2011 in Brain Stimulation
Verified
Journal Article
Closed access
ABAlexander Bystritsky
Alexander Bystritsky
AKAlex S. Korb
Alex S. Korb
PDPamela K. Douglas
Pamela K. Douglas
MCMark S. Cohen
Mark S. Cohen
WMWilliam P. Melega
William P. Melega
SYSeung-Schik Yoo
Seung-Schik Yoo

6 March 2011 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
BMByoung-Kyong Min
Byoung-Kyong Min
ABAlexander Bystritsky
Alexander Bystritsky
KJKwang-Ik Jung
Kwang-Ik Jung
KFKrisztina Fischer
Krisztina Fischer
YZYongzhi Zhang
Yongzhi Zhang
SYSeung-Schik Yoo
Seung-Schik Yoo
Background: Epilepsy is a common neurological disorder, which is attributed to uncontrollable abnormal hyper-excitability of neurons. We investigated the feasibility of using low-intensity, pulsed radiation of focused ultrasound (FUS) to non-invasively suppress epileptic activity in an animal model (rat), which was induced by the intraperitonial injection of pentylenetetrazol (PTZ).Results: After the onset of induced seizures, FUS was transcranially administered to the brain twice for three minutes each while undergoing electroencephalographic (EEG) monitoring. An air-backed, spherical segment ultrasound transducer (diameter: 6 cm; radius-of-curvature: 7 cm) operating at a fundamental frequency of 690 KHz was used to deliver a train of 0.5 msec-long pulses of sonication at a repetitive rate of 100 Hz to the thalamic areas of the brain. The acoustic intensity (130 mW/cm2) used in the experiment was sufficiently within the range of safety guidelines for the clinical ultrasound imaging. The occurrence of epileptic EEG bursts from epilepsy-induced rats significantly decreased after sonication when it was compared to the pre-sonication epileptic state. The PTZ-induced control group that did not receive any sonication showed a sustained number of epileptic EEG signal bursts. The animals that underwent sonication also showed less severe epileptic behavior, as assessed by the Racine score. Histological analysis confirmed that the sonication did not cause any damage to the brain tissue.Conclusions: These results revealed that low-intensity, pulsed FUS sonication suppressed the number of epileptic signal bursts using acute epilepsy model in animal. Due to its non-invasiveness and spatial selectivity, FUS may offer new perspectives for a possible non-invasive treatment of epilepsy.

1 November 2010 in Trends in Biotechnology
Verified
Journal Article
Closed access
BMByoung-Kyong Min
Byoung-Kyong Min
MMMatthew J. Marzelli
Matthew J. Marzelli
SYSeung-Schik Yoo
Seung-Schik Yoo

26 October 2011 in NeuroReport
Verified
Journal Article
Closed access
SYSeung-Schik Yoo
Seung-Schik Yoo
Hyungmin KimHyungmin Kim
Hyungmin Kim
BMByoung-Kyong Min
Byoung-Kyong Min
EFEric Franck
Eric Franck
SPShinsuk Park
Shinsuk Park
A pulsed application of focused ultrasound (FUS) to the regional brain tissue alters the state of tissue excitability and thus provides the means for noninvasive functional neuromodulation. We report that the application of transcranial FUS to the thalamus of anesthetized rats reduced the time to emergence of voluntary movement from intraperitoneal ketamine/xylazine anesthesia. Low-intensity FUS was applied to the thalamus of anesthetized animals. The times required for the animals to show distinct physiological/behavioral changes were measured and compared with those times required in a control session without sonication. The sonication significantly reduced the time to show pinch response and voluntary movement. The modulatory effects of FUS on anesthesia suggest potential therapeutic applications for disorders of consciousness such as minimally consciousness states.

1 July 2007 in International Journal of Psychophysiology
Verified
Journal Article
Closed access
BMByoung-Kyong Min
Byoung-Kyong Min
NBNiko A. Busch
Niko A. Busch
SDStefan Debener
Stefan Debener
CKCornelia Kranczioch
Cornelia Kranczioch
SHSimon Hanslmayr
Simon Hanslmayr
CHChristoph Herrmann
Christoph Herrmann