Theo Marcelo Galindo Chicaiza

Theo Marcelo Galindo Chicaiza

Auto-generated profile, based on publicly available information

Theo Marcelo Galindo Chicaiza

Universidad Técnica del Norte, Facultad de Ingeniería en Ciencias Aplicadas. Ibarra, Ecuador

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2025 in Data and Metadata
Verified
Journal Article
Open access
PDF file
TCTheo Marcelo Galindo Chicaiza
Theo Marcelo Galindo Chicaiza
Luz M. Tobar-Subía-ContentoLuz M. Tobar-Subía-Contento
Luz M. Tobar-Subía-Contento
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
MSMarco Ciaccia-Sortino, PhD Ciaccia Sortino
Marco Ciaccia-Sortino, PhD Ciaccia Sortino
CMCosme Mejia-Echeverria
Cosme Mejia-Echeverria
DMDiego Luis Ortiz Morales
Diego Luis Ortiz Morales
Introduction:Blood density measurement is a key diagnostic indicator for assessing hematological and cardiovascular conditions. Conventional methods require blood extraction and laboratory equipment. In this context, a non-invasive biomedical device based on photoplethysmography (PPG) and the Beer–Lambert law was developed to estimate blood density through optical parameters.Methods:A prototype was designed using a microcontroller, an optical sensor, and an OLED display. The acquired signals were digitally filtered through FIR and IIR algorithms to separate pulsatile and non-pulsatile components. Twenty-one volunteers were recruited, and sixteen valid recordings remained after artifact removal. Laboratory reference values were compared using linear regression and Bland–Altman analysis to evaluate concordance between clinical and device-derived measurements.Results:The device achieved an average error of 2.0 % for blood-density estimation, 6.06 % for hematocrit, and 7.01 % for erythrocyte count. The limits of agreement remained within clinically acceptable ranges, with a slight underestimation bias at higher density values. Main limitations were related to the restricted spectral range of the red and infrared LEDs and to physiological variables such as peripheral perfusion and involuntary movements.Conclusions:The proposed system demonstrated accuracy and stability for non-invasive blood-density estimation, validating PPG as a portable, low-cost diagnostic tool. Future improvements should include a broader calibration dataset and multispectral light sources with higher sensitivity to enhance linearity and dynamic range.