26 February 2023 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
19 June 2024 in Journal of Applied Clinical Medical Physics
Purpose: CBCT‐guided online‐adaptive radiotherapy (oART) systems have been made possible by using artificial intelligence and automation to substantially reduce treatment planning time during on‐couch adaptive sessions. Evaluating plans generated during an adaptive session presents significant challenges to the clinical team as the planning process gets compressed into a shorter window than offline planning. We identified MU variations up to 30% difference between the adaptive plan and the reference plan in several oART sessions that caused the clinical team to question the accuracy of the oART dose calculation. We investigated the cause of MU variation and the overall accuracy of the dose delivered when MU variations appear unnecessarily large.Methods: Dosimetric and adaptive plan data from 604 adaptive sessions of 19 patients undergoing CBCT‐guided oART were collected. The analysis included total MU per fraction, planning target volume (PTV) and organs at risk (OAR) volumes, changes in PTV‐OAR overlap, and DVH curves. Sessions with MU greater than two standard deviations from the mean were reoptimized offline, verified by an independent calculation system, and measured using a detector array.Results: MU variations relative to the reference plan were normally distributed with a mean of −1.0% and a standard deviation of 11.0%. No significant correlation was found between MU variation and anatomic changes. Offline reoptimization did not reliably reproduce either reference or on‐couch total MUs, suggesting that stochastic effects within the oART optimizer are likely causing the variations. Independent dose calculation and detector array measurements resulted in acceptable agreement with the planned dose.Conclusions: MU variations observed between oART plans were not caused by any errors within the oART workflow. Providers should refrain from using MU variability as a way to express their confidence in the treatment planning accuracy. Clinical decisions during on‐couch adaptive sessions should rely on validated secondary dose calculations to ensure optimal plan selection.
26 December 2025 in Journal of Applied Clinical Medical Physics
Purpose: Online adaptive radiation therapy (oART) has generated a significant influx of daily treatment planning data. Present oART platforms have leveraged automation for decreased planning times at the expense of end‐user access, making longitudinal oART data assessment time consuming. We have developed modified software that extracts oART data from the secondary calculation software associated with one of the oART platforms. Methods: A Python program was developed to query oART data from a web‐based secondary dose calculation software. Structure, plan, and dosimetric data were collected for all generated oART plans over the course of 3 years. This software stores data in a Pandas dataframe to allow for comparisons and advanced visualization. The software includes some pre‐defined visualization and analysis methods, as well as tools to de‐identify and share cohorts of oART data. Results: Twelve hundred oART sessions were pulled from our secondary dose verification software. Various visualization methods were implemented and are demonstrated in this technical note. This software demonstrated significant time savings in data extraction compared to manual session exports, but does not pull raw DICOM information, such as CT scans, structure sets, or dose files. Conclusion: Our extraction software presents a streamlined way to collect, analyze, and visualize oART data using a dedicated oART platform. Further tools are needed to improve access and analysis of oART data.