5 June 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
OLOlga Maria Dona Lemus
Olga Maria Dona Lemus
STSean Tanny
Sean Tanny
MCMichael Cummings
Michael Cummings
MWMatthew Webster
Matthew Webster
JWJoshua Wancura
Joshua Wancura
DZDandan Zheng
Dandan Zheng
Purpose: CBCT‐guided online adaptive radiotherapy (oART) plans presently utilize daily synthetic CTs (sCT) that are automatically generated using deformable registration algorithms. These algorithms may have poor performance at reproducing variable volumes of gas present during treatment. Therefore, we have analyzed the air mapping error between the daily CBCTs and the corresponding sCT and explored its dosimetric effect on oART plan calculation.Methods: Abdominopelvic air volume was contoured on both the daily CBCT images and the corresponding synthetic images for 207 online adaptive pelvic treatments. Air mapping errors were tracked over all fractions. For two case studies representing worst case scenarios, dosimetric effects of air mapping errors were corrected in the sCT images using the daily CBCT air contours, then recalculating dose. Dose volume histogram statistics and 3D gamma passing rates were used to compare the original and air‐corrected sCT‐based dose calculations.Results: All analyzed patients showed observable air pocket contour differences between the sCT and the CBCT images. The largest air volume difference observed in daily CBCT images for a given patient was 276.3 cc, a difference of more than 386% compared to the sCT. For the two case studies, the largest observed change in DVH metrics was a 2.6% reduction in minimum PTV dose, with all other metrics varying by less than 1.5%. 3D gamma passing rates using 1%/1 mm criteria were above 90% when comparing the uncorrected and corrected dose distributions.Conclusion: Current CBCT‐based oART workflow can lead to inaccuracies in the mapping of abdominopelvic air pockets from daily CBCT to the sCT images used for the optimization and calculation of the adaptive plan. Despite the large observed mapping errors, the dosimetric effects of such differences on the accuracy of the adapted plan dose calculation are unlikely to cause differences greater than 3% for prostate treatments.


16 November 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
MWMatthew Webster
Matthew Webster
STSean Tanny
Sean Tanny
NJNeil Joyce
Neil Joyce
AHAmy Herman
Amy Herman
YCYuhchyau Chen
Yuhchyau Chen
IYInhwan Yeo
Inhwan Yeo
Purpose To propose guidelines for lung stereotactic body radiation therapy (SBRT) when using Acuros XB (AXB) equivalent to the existing ones developed for convolution algorithms such as analytic anisotropic algorithm (AAA), considering the difference between the algorithms. Methods A retrospective analysis was performed on 30 lung patients previously treated with SBRT. The original AAA plans, which were developed using dynamic conformal arcs, were recalculated and then renormalized for planning target volume (PTV) coverage using AXB. The recalculated and renormalized plans were compared to the original plans based on V100% and V90% PTV coverage, as well as V105%, conformality index, D2cm, Rx/Dmax, R50, and Dmin. These metrics were analyzed nominally and on variations according to RTOG and NRG guidelines. Based on the relative difference between each metric in the AAA and AXB plans, new guidelines were developed. The relative differences in our cohort were compared to previously documented AAA to AXB comparisons found in the literature. Results AAA plans recalculated in AXB had a significant reduction in most dosimetric metrics. The most notable changes were in V100% (4%) and the conformality index (7.5%). To achieve equal PTV coverage, AXB required an average of 1.8% more monitor units (MU). This fits well with previously published data. Applying the new guidelines to the AXB plans significantly increased the number of minor violations with no change in major violations, making them comparable to those of the original AAA plans. Conclusion The relative difference found between AAA and AXB for SBRT lung plans has been shown to be consistent with previous works. Based on these findings, new guidelines for lung SBRT are recommended when planning with AXB.

26 April 2025 in Cancers
Verified
Journal Article
Open access
PDF file
DZDandan Zheng
Dandan Zheng
MCMichael Cummings
Michael Cummings
HZHong Zhang
Hong Zhang
APAlexander Podgorsak
Alexander Podgorsak
FLFiona Li
Fiona Li
STSean Tanny
Sean Tanny
Background/Objectives: Cone-beam computed tomography (CBCT)-guided online adaptive radiotherapy (oART) represents a significant advancement in radiation oncology, enabling on-couch plan adaptation to account for daily anatomical changes. While this automation improves precision and workflow efficiency, it also introduces new failure modes (FMs) and workflow irregularities. This study aimed to systematically evaluate the clinical and technical challenges associated with CBCT-guided oART implementation. Methods: We retrospectively analyzed over 1000 CBCT-guided oART sessions for pelvic malignancies performed at our institution. A multidisciplinary team conducted a comprehensive review to identify and classify FMs, followed by root cause analysis (RCA) to evaluate their impact on treatment safety, efficacy, and workflow robustness. Results: In addition to session-terminating FMs, we identified recurring failure modes across three major domains: (1) system-driven issues, such as rigid target localization and software-driven irregularities; (2) patient-driven challenges, including interfractional and intrafractional anatomical variations; and (3) treatment planning and execution failures, including excessive dose hotspots from field-of-view limitations. The system’s closed-loop automation, while streamlining processes, introduced rigid constraints in plan adaptation and fallback plan execution, occasionally leading to unintended dose discrepancies. Conclusions: This study provides a comprehensive clinical practice-based evaluation of CBCT-guided oART, highlighting system-specific failure modes and their implications. Addressing these challenges requires structured quality assurance processes, multidisciplinary collaboration, and continuous workflow refinement. Our findings contribute to the development of safer and more robust adaptive radiotherapy platforms and clinical workflows.

1 December 2019 in Lung Cancer: Targets and Therapy
Verified
Journal Article
Open access
PDF file
MMMichael Mix
Michael Mix
STSean Tanny
Sean Tanny
TNTamara Nsouli
Tamara Nsouli
RARyan Alden
Ryan Alden
RCRishabh Chaudhari
Rishabh Chaudhari
PAPaul Aridgides
Paul Aridgides
Introduction: The treatment techniques used for stereotactic body radiation therapy (SBRT) for early-stage lung cancer continue to evolve. In this study, clinical outcomes following SBRT were evaluated according to the use of either 3D conformal radiotherapy (3DCRT) or intensity-modulated radiation therapy (IMRT). Patients and methods: Patients with stage I NSCLC who received SBRT from 2007 to 2015 were retrospectively reviewed. Disease control and survival were assessed using Kaplan-Meier estimates. Dosimetric analyses for target dose heterogeneity and coverage were performed. Results: A total of 297 patients with 351 lesions were included. 3DCRT was used in 52% and IMRT in 48%. IMRT was utilized at a higher rate in more recent years. The most common regimens were 48 Gy in 4 fractions and 54–60 Gy in 3 fractions. With a median follow up of 22.7 months, there were 17 local failures for a crude relapse rate of 5.7%. Local failure did not differ in patients treated with 3DCRT and IMRT (4.9% vs 6.5%, p=0.573). Mean dose to gross tumor volume (GTV) as a percent of prescription dose was higher with 3DCRT compared with IMRT (107.7% vs 103.6%, p < 0.0001). Tumor stage, histology, and SBRT regimen did not correlate with local tumor control. Overall survival for the entire population approximated 72% at 2 years. Treatment was well tolerated with 6 documented grade 3+ events. Conclusion: In this single-institution cohort of SBRT for early-stage NSCLC, there was no discernible difference in clinical outcomes between those treated with 3DCRT and IMRT.

19 June 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
STSean Tanny
Sean Tanny
OLOlga M Dona Lemus
Olga M Dona Lemus
JWJoshua Wancura
Joshua Wancura
NSNicholas Sperling
Nicholas Sperling
MWMatthew Webster
Matthew Webster
DZDandan Zheng
Dandan Zheng
Purpose: CBCT‐guided online‐adaptive radiotherapy (oART) systems have been made possible by using artificial intelligence and automation to substantially reduce treatment planning time during on‐couch adaptive sessions. Evaluating plans generated during an adaptive session presents significant challenges to the clinical team as the planning process gets compressed into a shorter window than offline planning. We identified MU variations up to 30% difference between the adaptive plan and the reference plan in several oART sessions that caused the clinical team to question the accuracy of the oART dose calculation. We investigated the cause of MU variation and the overall accuracy of the dose delivered when MU variations appear unnecessarily large.Methods: Dosimetric and adaptive plan data from 604 adaptive sessions of 19 patients undergoing CBCT‐guided oART were collected. The analysis included total MU per fraction, planning target volume (PTV) and organs at risk (OAR) volumes, changes in PTV‐OAR overlap, and DVH curves. Sessions with MU greater than two standard deviations from the mean were reoptimized offline, verified by an independent calculation system, and measured using a detector array.Results: MU variations relative to the reference plan were normally distributed with a mean of −1.0% and a standard deviation of 11.0%. No significant correlation was found between MU variation and anatomic changes. Offline reoptimization did not reliably reproduce either reference or on‐couch total MUs, suggesting that stochastic effects within the oART optimizer are likely causing the variations. Independent dose calculation and detector array measurements resulted in acceptable agreement with the planned dose.Conclusions: MU variations observed between oART plans were not caused by any errors within the oART workflow. Providers should refrain from using MU variability as a way to express their confidence in the treatment planning accuracy. Clinical decisions during on‐couch adaptive sessions should rely on validated secondary dose calculations to ensure optimal plan selection.