Mingyu Zhou

Mingyu Zhou

Auto-generated profile, based on publicly available information

Mingyu Zhou

Global Energy Interconnection Research Institute Europe GmbH

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2021
Verified
Conference Paper
Closed access
YDYi Ding
Yi Ding
Yalin WangYalin Wang
Yalin Wang
MZMingyu Zhou
Mingyu Zhou
Hao SunHao Sun
Hao Sun
WLWenyi Li
Wenyi Li
YYYi Yin
Yi Yin
Exploring the partial discharge (PD) characteristics of power modules under square wave high electric fields with short rise and fall time is of great significance for improving the reliability of its packaging insulation. In this paper, a PD detection method based on super high frequency (SHF, 3-30 GHz) technique and signal down-mixing principle is applied to detect the PD under square wave. The power module packaging insulation specimen consisting of metal baseplate, direct bonding copper (DBC), substrate and housing is fabricated. A repetitive square wave generator is built to supply high voltage square waves with short transition time. PD experiments are performed under square wave and sinusoidal wave. Experimental results show that the SHF-down-mixing PD detection system can effectively suppress the electromagnetic interference (EMI) from the square wave and extract PD signals successfully. As the radius of the electrode corner increases, the partial discharge inception voltage (PDIV) values under the sinusoidal wave also gradually increases. The PDIV under square wave does not show a monotonically increasing and is usually higher than that under sinusoidal wave probably because of the effect of space charge accumulation.

26 September 2023 in Mechanics of Materials
Verified
Journal Article
Open access
XWXin Wang
Xin Wang
RXRuoyu Xu
Ruoyu Xu
MZMingyu Zhou
Mingyu Zhou
SMShanika Matharage
Shanika Matharage
YZYuzhen Zhou
Yuzhen Zhou
ZWZhongdong Wang
Zhongdong Wang

6 September 2020
Verified
Conference Paper
Closed access
HWHaitian Wang
Haitian Wang
MZMingyu Zhou
Mingyu Zhou
RPRonald Plath
Ronald Plath
ZHZhengyi Han
Zhengyi Han
XLXingeng Li
Xingeng Li
AEAndreas Elben
Andreas Elben
Extruded cross-linked polyethylene (XLPE) cables have become the preferred choice for the VSC-HVDC, due to benefits like easier production, transportation, and installation compared with MI cable. For AC cables, partial discharge testing is a vital method to evaluate the condition of the cable. However, there is significantly less experience regarding the behavior of partial discharge under DC conditions. It is well known that failures arise more often in accessories than in the cable itself. In order to evaluate partial discharges for a typical installation defect, a sharp transition edge between the outer semicon and the insulation layer has been prepared on an 80kV DC-cable system. Under different cable conductor temperatures, partial discharge tests with DC voltage steps have been performed with and without pulsed xray. For comparison, PD measurements at AC have also been performed on the DC-cable. Finally, the partial discharge inception voltage (PDIV) under DC and AC has been compared, and the dependence of temperature and X-ray pulses for DC partial discharge is investigated.

11 April 2021
Verified
Conference Paper
Closed access
HWHaitian Wang
Haitian Wang
YLYi Luo
Yi Luo
TFTobias Fechner
Tobias Fechner
CZChong Zhang
Chong Zhang
ZLZhengtong Lu
Zhengtong Lu
MZMingyu Zhou
Mingyu Zhou
The cable termination is one of the vulnerable parts of the whole system. For oil-filled terminations, internal breakdown can produce severe damage to the surrounding equipment and human beings. At present, the rated voltage of gas-filled plug-in AC cable terminations is up to 550 kV and a lot of engineering and application experience shows that the gas-filled plug-in cable terminations have the benefits of no isolation liquids, shorter installation time and compacter design. In order to introduce the advantages of plug-in cable termination of AC power systems for DC power systems, it is necessary to carry out simulation modeling research on plug-in DC cable terminations. Based on the accumulated experience in the development of DC cable accessories, in this paper, a model of a 200 kV plug-in DC cable termination is presented and used to simulate the interfacial electric field under typical conditions according to relevant type test standards for DC cable systems.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
RXRuoyu Xu
Ruoyu Xu
MZMingyu Zhou
Mingyu Zhou
HYHaonan Yang
Haonan Yang
YDYi Ding
Yi Ding
TLTan Liu
Tan Liu
ZWZhongdong Wang
Zhongdong Wang

6 September 2020
Verified
Conference Paper
Closed access
MZMingyu Zhou
Mingyu Zhou
HWHaitian Wang
Haitian Wang
BFBenhui Fan
Benhui Fan
CZChong Zhang
Chong Zhang
YZYuzhen Zhou
Yuzhen Zhou
JBJinbo Bai
Jinbo Bai
The performances of dielectric film capacitors depend directly on the dielectric materials. High-performance capacitors must be supported by dielectric materials with high dielectric properties and high energy storage density. The dielectric constant of conventional dielectric materials has inherent contradiction with its dielectric strength, therefore, the development of a new film dielectric material with excellent dielectric performance and suitable for efficient energy storage density is conducive to greatly increasing the capacity of capacitors and miniaturization of applications. This paper introduces the research progress of high-performance with nanofiller modified film materials, discusses the modification technology on improving the electrical properties, and discusses the feasible blending, grafting and nano modification technologies of polypropylene. The analysis shows that the modification of nano - blend polypropylene can improve the dielectric constant and dielectric strength of materials.