Jamison E. Thorne

Jamison E. Thorne

Auto-generated profile, based on publicly available information

Jamison E. Thorne

Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2022 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JBJ.C. Benson
J.C. Benson
KRKishore Rajendran
Kishore Rajendran
JLJohn Lane
John Lane
FDF.E. Diehn
F.E. Diehn
NWN.M. Weber
N.M. Weber
SLS. Leng
S. Leng
Active electrocorticogram (ECoG) electrodes can amplify the weak electrophysiological signals and improve the anti-interference ability, but the traditional active electrodes are so opaque that cannot realize photoelectric collaborative observation. Here an active and fully-transparent ECoG array based on zinc oxide-thin film transistors (ZnO-TFTs) was developed as the local neural signal amplifier for electrophysiological monitoring. The transparency of the proposed ECoG array was up to 85% which is superior to previous reported active electrode array. Various electrical characterizations demonstrated its ability of electrophysiological signal recording, with a higher signal-to-noise ratio of 19.9 dB compared to the Au grid one (13.2 dB). The high transparency of ZnO-TFT electrode array allowed the collecting electrophysiological signals under direct light stimulation on optogenetic mice brain concurrently. The ECoG array could also work under 7-Tesla magnetic resonance imaging to record local brain signal without affecting brain tissue imaging. As the most transparent active ECoG array to date, it provides a powerful multimodal tool for brain observation, including recording brain activity under synchronized optical modulation and 7-Tesla magnetic resonance imaging.

7 November 2023 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
EKEmily K. Koons
Emily K. Koons
PRPrabhakar Rajiah
Prabhakar Rajiah
JTJamison E. Thorne
Jamison E. Thorne
NWNikkole M. Weber
Nikkole M. Weber
HKHolly J. Kasten
Holly J. Kasten
SLShuai Leng
Shuai Leng

1 December 2023 in Radiology
Verified
Journal Article
Closed access
CMCynthia H. McCollough
Cynthia H. McCollough
PRPrabhakar Rajiah
Prabhakar Rajiah
JBJohn P. Bois
John P. Bois
TWTim N. Winfree
Tim N. Winfree
RCRickey Edward Carter
Rickey Edward Carter
SLShuai Leng
Shuai Leng
Background Compared with energy-integrating detector (EID) CT, the improved resolution of photon-counting detector (PCD) CT coupled with high-energy virtual monoenergetic images (VMIs) has been shown to decrease calcium blooming on images in phantoms and cadaveric specimens. Purpose To determine the impact of dual-source PCD CT on visual and quantitative estimation of percent diameter luminal stenosis compared with dual-source EID CT in patients. Materials and Methods This prospective study recruited consecutive adult patients from an outpatient facility between January and March 2022. Study participants underwent clinical dual-source EID coronary CT angiography followed by a research dual-source PCD CT examination. For PCD CT, multienergy data were used to create VMIs at 50 and 100 keV. Two readers independently reviewed EID CT images followed by PCD CT images after a washout period. Readers visually graded the most severe stenosis in terms of percent diameter luminal stenosis for the left main, left anterior descending, right, and circumflex coronary arteries, unblinded to scanner type. Quantitative measures of percent stenosis were made using commercial software. Visual and quantitative estimates of percent stenosis were compared between EID CT and PCD CT using the Wilcoxon signed-rank test. Results A total of 25 participants (median age, 59 years [range, 18-78 years]; 16 male participants) were enrolled. On EID CT images, readers 1 and 2 identified 39 and 32 luminal stenoses, respectively, with a percent diameter luminal stenosis greater than 0%. Visual estimates of percent stenosis were lower on PCD CT images than EID CT images (reader 1: median 20.6% [IQR, 8.8%-61.2%] vs 31.8% [IQR, 12.9%-69.7%], P < .001; reader 2: 6.5% [IQR, 0.4%-54.1%] vs 22.9% [IQR, 1.8%-67.4%], P = .002). No difference was observed between EID CT and PCD CT for quantitative measures of percent stenosis (median difference, -1.5% [95% CI: -3.0%, 2.5%]; P = .51). Conclusion Relative to using EID CT, using PCD CT led to decreases in visual estimates of percent stenosis. © RSNA, 2023 See also the editorial by Murphy and Donnelly in this issue.

5 September 2024 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
FDFelix E. Diehn
Felix E. Diehn
ZZZhongxing Zhou
Zhongxing Zhou
JTJamison E. Thorne
Jamison E. Thorne
NCNorbert G. Campeau
Norbert G. Campeau
ANAlex A. Nagelschneider
Alex A. Nagelschneider
LYLifeng Yu
Lifeng Yu
BACKGROUND AND PURPOSE: Photon-counting detector CT (PCD-CT) is now clinically available and offers ultra-high–resolution (UHR) imaging. Our purpose was to prospectively evaluate the relative image quality and impact on diagnostic confidence of head CTA images acquired by using a PCD-CT compared with an energy-integrating detector CT (EID-CT). MATERIALS AND METHODS: Adult patients undergoing head CTA on EID-CT also underwent a PCD-CT research examination. For both CT examinations, images were reconstructed at 0.6 mm by using a matched standard resolution (SR) kernel. Additionally, PCD-CT images were reconstructed at the thinnest section thickness of 0.2 mm (UHR) with the sharpest kernel, and denoised with a deep convolutional neural network (CNN) algorithm (PCD-UHR-CNN). Two readers (R1, R2) independently evaluated image quality in randomized, blinded fashion in 2 sessions, PCD-SR versus EID-SR and PCD-UHR-CNN versus EID-SR. The readers rated overall image quality (1 [worst] to 5 [best]) and provided a Likert comparison score (−2 [significantly inferior] to 2 [significantly superior]) for the 2 series when compared side-by-side for several image quality features, including visualization of specific arterial segments. Diagnostic confidence (0–100) was rated for PCD versus EID for specific arterial findings, if present. RESULTS: Twenty-eight adult patients were enrolled. The volume CT dose index was similar (EID: 37.1 ± 4.7 mGy; PCD: 36.1 ± 4.0 mGy). Overall image quality for PCD-SR and PCD-UHR-CNN was higher than EID-SR (eg, PCD-UHR-CNN versus EID-SR: 4.0 ± 0.0 versus 3.0 ± 0.0 (R1), 4.9 ± 0.3 versus 3.0 ± 0.0 (R2); all P values < .001). For depiction of arterial segments, PCD-SR was preferred over EID-SR (R1: 1.0–1.3; R2: 1.0–1.8), and PCD-UHR-CNN over EID-SR (R1: 0.9–1.4; R2: 1.9–2.0). Diagnostic confidence of arterial findings for PCD-SR and PCD-UHR-CNN was significantly higher than EID-SR: eg, PCD-UHR-CNN versus EID-SR: 93.0 ± 5.8 versus 78.2 ± 9.3 (R1), 88.6 ± 5.9 versus 70.4 ± 5.0 (R2); all P values < .001. CONCLUSIONS: PCD-CT provides improved image quality for head CTA images compared with EID-CT, both when PCD and EID reconstructions are matched, and to an even greater extent when PCD-UHR reconstruction is combined with a CNN denoising algorithm.

11 November 2024 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
SCShaojie Chang
Shaojie Chang
JBJohn C. Benson
John C. Benson
JLJohn Lane
John Lane
MBMichael R. Bruesewitz
Michael R. Bruesewitz
JSJoseph R. Swicklik
Joseph R. Swicklik
SLShuai Leng
Shuai Leng
BACKGROUND AND PURPOSE: Ultra-high-resolution (UHR) photon-counting-detector (PCD) CT improves image resolution but increases noise, necessitating use of smoother reconstruction kernels that reduce resolution below the system’s 0.110 mm maximum spatial resolution. To address this, a denoising convolutional neural network (CNN) was developed to reduce noise in images reconstructed with the available sharpest reconstruction kernel while preserving resolution for enhanced temporal bone visualization. MATERIALS AND METHODS: With IRB approval, CNN was trained on 6 clinical temporal bone patient cases (1,885 images) and tested on 20 independent cases using a dual-source PCD-CT (NAEOTOM Alpha, Siemens). Images were reconstructed using iterative reconstruction at strength 3 (QIR3) with both clinical routine (Hr84) and the sharpest available head kernel (Hr96). The CNN was applied to images reconstructed with Hr96 and QIR1. Three image series (Hr84-QIR3, Hr96-QIR3, and Hr96-CNN) for each case were randomized for review by two neuroradiologists, assessing overall quality and delineation of the modiolus, stapes footplate, and incudomallear joint. RESULTS: CNN reduced noise by 80% compared to Hr96-QIR3 and 50% relative to Hr84-QIR3, while maintaining high resolution. When compared to the conventional method at the same kernel (Hr96-QIR3), Hr96-CNN significantly decreased image noise (from 204.63 HU to 47.35 HU) and improved SSIM (from 0.72 to 0.99). Hr96-CNN images ranked higher than Hr84-QIR3 and Hr96-QIR3 in overall quality (p<0.001). Readers preferred Hr96-CNN for all three structures. CONCLUSIONS: The proposed CNN significantly reduced image noise in UHR PCD-CT, enabling the use of sharpest kernel. This combination greatly enhanced diagnostic image quality and anatomical visualization. ABBREVIATIONS: PCD = Photon-counting-detector; UHR = Ultra-high-resolution; IR = Iterative reconstruction; CNN = Convolutional neural network; SSIM: Structural similarity index.

10 February 2025 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
AMAjay A. Madhavan
Ajay A. Madhavan
ZZZhongxing Zhou
Zhongxing Zhou
PFPaul J. Farnsworth
Paul J. Farnsworth
JTJamison Thorne
Jamison Thorne
TATimothy J. Amrhein
Timothy J. Amrhein
LYLifeng Yu
Lifeng Yu
BACKGROUND AND PURPOSE: Photon counting detector CT myelography is a recently described technique used for detecting spinal CSF leaks, including CSF-venous fistulas. Various image reconstruction techniques, including smoother versus sharper kernels and virtual monoenergetic images, are available with photon counting CT. Moreover, denoising algorithms have shown promise in improving sharp kernel images. No prior studies have compared image quality of these different reconstructions on photon counting CT myelography. Here, we sought to compare several image reconstructions using various parameters important for the detection of CSF-venous fistulas. MATERIALS AND METHODS: We performed a retrospective review of all consecutive decubitus photon counting CT myelograms performed between 2/1/2022 and 8/1/2024 at one institution. We included patients whose studies had the following reconstructions: Br48-40 keV virtual monoenergetic reconstruction, Br56 low energy threshold (T3D), Qr89-T3D denoised with quantum iterative reconstruction, and Qr89-T3D denoised with a convolutional neural network algorithm. We excluded patients who had extradural CSF on preprocedural imaging or a technically unsatisfactory myelogram. All four reconstructions were independently reviewed by two neuroradiologists. Each reviewer rated spatial resolution, noise, presence of artifacts, image quality, and diagnostic confidence (whether positive or negative) on a 1-5 scale. These metrics were compared using the Friedman test. Additionally, noise and contrast were quantitatively assessed by a third reviewer and compared. RESULTS: The Qr89 reconstructions demonstrated higher spatial resolution than their Br56 or Br48-40keV counterparts. Qr89 with convolutional neural network denoising had less noise, better image quality, and improved diagnostic confidence compared to Qr89 with quantum iterative reconstruction denoising. The Br48-40keV reconstruction had the highest contrast-to-noise ratio quantitatively. CONCLUSIONS: In our study, the sharpest quantitative kernel (Qr89-T3D) with convolutional neural network denoising demonstrated the best performance with regards to spatial resolution, noise level, image quality, and diagnostic confidence for detecting or excluding the presence of a CSF-venous fistula. ABBREVIATIONS: CNR = contrast-to-noise ratio; CVF = CSF-venous fistula; EID = energy integrating detector; PCD = photon counting detector; PCD-CTM = photon counting detector CT myelography; ROI = region of interest; SNR = signal-to-noise ratio; SIH = spontaneous intracranial hypotension; T3D = low-energy threshold; UHR = ultra-high resolution.