12 December 2024 in IEEE Transactions on Applied Superconductivity
The development of a fabrication process for Josephson junctions (JJs) using a direct-write helium-focused ion beam (He-FIB) technique provides the opportunity to control parameters such as the critical current $I_{\mathrm{c}}$ and normal-state resistance $R_{\mathrm{n}}$ of individual JJs in YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJ arrays. Such arrays could be used as a voltage calibration standard that is operated at higher temperatures and higher driving frequencies than the currently used niobium JJ arrays. This study presents the fabrication process of 79 YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJs in a meander array design using a direct writing He-FIB process with the same irradiation dose for all JJs. In this design, each of the JJs can be measured individually, and adjacent JJs that exhibit similar and suitable parameters for a voltage standard array can be measured in series. The scattering of the JJ parameters was investigated at 5 K and resulted in a spread in $I_{\mathrm{c}}$ of about 60% and in $R_{\mathrm{n}}$ of 25%. However, a couple of subarrays with a spread lower than 10% could be found. In addition, these JJ subarrays were irradiated with high-frequency radiation in the GHz and THz range at a temperature of 20 K and synchronization of up to three JJs was observed in both frequency ranges.
1 April 2025 in Review of Scientific Instruments
Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance–voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system’s measurement capability for quantum computing and other applications.
15 December 2025 in IEEE Transactions on Applied Superconductivity
Fabrication of YBa2Cu3O7-x Josephson junctions (JJs) using a direct-write helium-focused helium ion beam (He-FIB) technique has great potential for various applications due to tunable JJ parameters and arbitrary positioning. This technique allows placing multiple JJs in series to create JJ arrays. They could be used as a voltage standard that is operated at higher temperatures and driving frequencies than the currently used niobium-based JJ arrays. Small YBa2Cu3O7-x He-FIB JJ arrays with superposed Shapiro steps for up to three JJs have already been demonstrated. The number of JJs in the array was limited by the parameter spread of the individual JJs. This study presents WRspice simulations of JJ arrays, which indicate that the normal state resistance $R$n is the most crucial parameter to achieve flat Shapiro steps in JJ arrays. The idea of adding a shunt resistor to the JJ array to deal with the spread in $R$n values is investigated. A new design for GHz frequencies is presented, and the fabrication process is described. The properties of the shunt resistor are evaluated by van der Pauw measurements. Comparison of measurements with and without shunt resistor shows the desired effect of changing the total resistance of the JJ array while maintaining the critical current value. Finally, measurements of JJ arrays demonstrating superposed Shapiro steps at 20 k at GHz frequencies are presented.
29 January 2026 in IEEE Transactions on Applied Superconductivity
Recent results with shunted YBa2Cu3O7-x Josephson junctions (JJs) fabricated using direct-writing by helium-focused ion beam (He-FIB) demonstrate that this technology is useful to achieve a YBa2Cu3O7-x voltage standard. By adding a shunt resistor via a subsequent lift-off step, the $\rm{{\mathit{R}}}_\rm{n}$ value and thereby the spread of the JJs can be reduced. These results were achieved with one large shunt across multiple JJs. This study presents different designs of shunt resistors, which allow measuring the JJs individually. The different shunt resistor designs are described and evaluated by comparing measurement results without and with the shunt resistor. These show the desired effect of controlling $\rm{{\mathit{R}}}_\rm{n}$, but also a change in $\rm{{\mathit{I}}}_\rm{c}$ is visible. The spread in parameters is investigated both without and with shunt resistors. Shapiro steps at gigahertz frequencies are presented for single JJs. The study concludes with a comparative measurement between a YBa2Cu3O7-x He-FIB JJ and a Josephson Arbitrary Waveform Synthesizer from PTB Braunschweig, showing a deviation of 0.05% and thus demonstrating its potential applicability.
12 January 2026 in IEEE Transactions on Applied Superconductivity
Josephson junctions (JJs) embedded into the feed point of a thin film antenna made from yttrium barium copper oxide (YBCO) are well suited as a miniature sensor for GHzand THz-frequency fields. A spatially and frequency-resolved image of electromagnetic field intensity is obtained by scanning the region of interest. The sensor is read out by measuring the dc current-voltage (IV) characteristic of the JJ. Discrete frequencies together with their corresponding intensities can be extracted from measurements by evaluating the Shapiro steps in the IV domain. To extract a continuous spectrum from the IV characteristic, the numerical method of Hilbert transform spectroscopy is used and its applicability to our JJs is evaluated. As a benchmark of the setup's capabilities, radiation from a quantum cascade laser (QCL) THz source is characterized both spectrally and spatially. A frequency comb spectrum consistent with the QCL's cavity is revealed by Hilbert transform spectroscopy. The far field radiation patterns of two strong QCL modes are resolved individually and show different characteristics. Optical QCL feedback is observed when the sensor is brought in close proximity.
24 February 2026 in IEEE Transactions on Applied Superconductivity
Josephson junctions based on high-temperature su-perconductors enable the detection of terahertz (THz) radiation at frequencies up to 5 THz. Their current-voltage characteristics provide information on the incident intensity and frequency of gigahertz and terahertz radiation, with coupling eficiency enhanced through the use of integrated antennas. This detector, called a Josephson cantilever, is employed in our THz scanning microscope to map three-dimensional far-field patterns. The cantilevers are fabricated on lanthanum aluminate-strontium aluminum tantalate (LSAT) or magnesium (MgO) substrates with epitaxially grown yttrium barium copper oxide (YBCO) thin films. Focused-helium ion beam direct writing is used to write Josephson junctions in the antenna feed points. These narrowband u-shaped antennas are designed for specific resonant frequencies, requiring the determination of the YBCO's surface impedance. The temperature-dependent surface impedance of YBCO was determined using terahertz spectroscopy (300 GHz to 2 THz, 10 K to 300 K) and validated against measured antenna resonances that were compared to finite integration simulations in CST Studio Suite 2023. Finally, spatially resolved measurements at 1.4 THz demonstrate the imaging capabilities with symmetric Gaussian beam profiles.