The measurement of geochemical parameters such as He and CO2 concentrations are important and useful for the study of characterization of volcanic systems and seismically active areas. Furthermore, the He/CO2 ratio gives useful information on the depth of the outgassing origin. Finally, extensive parameters such as He and CO2 flux are even more binding in the interpretation and modeling of these systems in question.In an ambitious move to volcanic risk mitigation, INFICON GmbH—a global leader in measurement and sensor technology—has partnered with premier scientific institutions (INGV_Italy) to monitor active volcanic centers on Italy’s Vulcano and Stromboli islands. The research focuses on the characterization of natural volcanic emissions at Stromboli and Vulcano (Aeolian Archipelago, Italy), where an advanced geochemical monitoring network for deep-seated fluids is currently operational. A key development in this study involves the deployment of a high-resolution instrument for the continuous measurement of helium (He) concentrations. This device was strategically located with an existing station monitoring soil CO2 flux to investigate the temporal correlation between different volatile species. The 'He-Man' sensor is a cutting-edge helium detector designed for field deployment. It employs a selective helium-permeable membrane to isolate the analyte from the atmospheric matrix, followed by a Penning ionization process to quantify the gas. This setup allows for the detection of trace levels of helium, providing a high-fidelity proxy for the arrival of primitive, mantle-derived fluids within the volcanic plumbing system.Two 'He-Man' instruments were successfully deployed across the Aeolian Archipelago to monitor high-frequency helium variations. The first unit was installed at Vulcano Island, positioned in a target area characterized by anomalous diffuse soil degassing. The second unit was deployed on Stromboli Island, integrated within a thermal well monitoring system. In the latter configuration, the sensor is coupled with a specialized sampling interface designed for the real-time analysis of dissolved gases in the hydrothermal aquifer. These dual installations enable a comparative study of helium behavior in both sub-aerial and sub-aqueous volcanic environments.Soils anomalous degassing:By coupling the 'He-Man' instrument with a high-precision infrared CO2 detector, we are able to determine the He/CO2 concentration ratio within a sub-surface probe (sampling pipe) installed at the Palizzi site. This monitoring point is strategically located adjacent to the Palizzi station, which provides continuous measurements of diffuse CO2 soil fluxes. Utilizing this integrated setup, the helium soil flux (JHe) is indirectly quantified by scaling the measured He/CO2 ratio against the absolute CO2 flux (JCO2) according to the relation: JHe = ([He]/[CO2])*J(CO2) Dissolved CO2 in natural waters:By integrating this helium concentration sensor with an automated system for monitoring dissolved CO2 in a thermal well at Stromboli, we have successfully characterized the He/CO2 ratio within the hydrothermal environment. This setup targets the specific aquifer situated between the degassing magma body and the anomalous diffuse degassing areas of Scari. This integrated monitoring approach provides critical insights into the geochemical evolution of fluids as they migrate from the magmatic source through the island's groundwater system toward the surface.
Mt. Etna has long been considered one of the major sources of volcanic gases worldwide. Variations in degassing activity have been therefore considered as precious indications about the activity status of the volcanic system. Though most of the gases are released by open-conduit degassing through the summit craters, a significant part of the gases diffuses through the flanks of the volcano interacting with groundwater. Acquisition of physico-chemical parameters in groundwater for volcanic surveillance purposes started on Mt. Etna nearly 40 year ago. While in the first years only periodic sampling, generally with a monthly frequency, was made, in recent years automatic monitoring stations with higher acquisition frequency (hourly) and data transmission were implemented in several groundwater sampling sites.Moreover, the complex geodynamic situation of the eastern flank of the volcano, with tectonic and volcano-tectonic activity and flank sliding, will also have some influence on the acquired signals at the groundwater monitoring stations.In this framework, important results are expected from monitoring of the high-frequency oscillations of water level of aquifers, a powerful tool in studying stress and strain conditions in the crust. The present experiment will represent the first time that this portion of the spectrum of the water level signal will be explored in the attempt to recognize possible precursory patterns. Given the peculiarity of the area, we will focus on episodes of magma migration, volcano tectonic events and degassing, as recognized by ground deformation, seismicity and geochemical signals, which cause the propagation elastic energy in the aquifer and can thus produce high-frequency pressure signals. The presence on the area of a well-developed network for measurement of ground deformation will allow in fact to relate our hydrological signals to inflation, deflation of the edifice and sliding of its eastern flank.A prototype station for measurement of high-frequency (from 0.1 to 50 Hz) variation of pore pressure with an innovative absolute pressure sensor in 2.5mm case with 24bit resolution and 0-2 or 0-4 bar range has been implemented. The station acquires also the following parameters: water temperature, pH, electric conductivity. For the necessary tests, the station will be placed soon in an abandoned well with limited anthropogenic interference in the surrounding area on the eastern flank of Mt. Etna.