Jorge Andres Diaz

Jorge Andres Diaz

Auto-generated profile, based on publicly available information

Jorge Andres Diaz

Universidad de Costa Rica (UCR), GasLab, CICANUM, San José, Costa Rica

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2017 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
ATAnne M. Thompson
Anne M. Thompson
JWJacquelyn C. Witte
Jacquelyn C. Witte
CSChance Sterling
Chance Sterling
AJAllen Jordan
Allen Jordan
BJBryan J. Johnson
Bryan J. Johnson
KTKennedy Thiongo
Kennedy Thiongo
The Southern Hemisphere ADditional OZonesonde (SHADOZ) network was assembled to validate a new generation of ozone‐monitoring satellites and to better characterize the vertical structure of tropical ozone in the troposphere and stratosphere. Beginning with nine stations in 1998, more than 7,000 ozone and P‐T‐U profiles are available from 14 SHADOZ sites that have operated continuously for at least a decade. We analyze ozone profiles from the recently reprocessed SHADOZ data set that is based on adjustments for inconsistencies caused by varying ozonesonde instruments and operating techniques. First, sonde‐derived total ozone column amounts are compared to the overpasses from the Earth Probe/Total Ozone Mapping Spectrometer, Ozone Monitoring Instrument, and Ozone Mapping and Profiler Suite satellites that cover 1998–2016. Second, characteristics of the stratospheric and tropospheric columns are examined along with ozone structure in the tropical tropopause layer (TTL). We find that (1) relative to our earlier evaluations of SHADOZ data, in 2003, 2007, and 2012, sonde‐satellite total ozone column offsets at 12 stations are 2% or less, a significant improvement; (2) as in prior studies, the 10 tropical SHADOZ stations, defined as within ±19° latitude, display statistically uniform stratospheric column ozone, 229 ± 3.9 DU (Dobson units), and a tropospheric zonal wave‐one pattern with a 14 DU mean amplitude; (3) the TTL ozone column, which is also zonally uniform, masks complex vertical structure, and this argues against using satellites for lower stratospheric ozone trends; and (4) reprocessing has led to more uniform stratospheric column amounts across sites and reduced bias in stratospheric profiles. As a consequence, the uncertainty in total column ozone now averages 5%.

6 February 2019 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
JMJ. M. de Moor
J. M. de Moor
JSJohn Stix
John Stix
GAG. Avard
G. Avard
CMC. Muller
C. Muller
ECE. Corrales
E. Corrales
TFTobias P. Fischer
Tobias P. Fischer
Identification of unambiguous signals of volcanic unrest is crucial in hazard assessment. Processes leading to phreatic and phreatomagmatic eruptions remain poorly understood, inhibiting effective eruption forecasting. Our 5‐year gas record from Poás volcano, combined with geophysical data, reveals systematic behavior associated with hydrothermal‐magmatic eruptions. Three eruptive episodes are covered, each with distinct geochemical and geophysical characteristics. Periods with larger eruptions tend to be associated with stronger excursions in monitoring data, particularly in SO2/CO2 and SO2 flux. The explosive 2017 phreatomagmatic eruption was the largest eruption at Poás since 1953 and was preceded by dramatic changes in gas and geophysical parameters. The use of drones played a crucial role in gas monitoring during this eruptive period. Hydrothermal sealing and volatile accumulation, followed by top‐down reactivation of a shallow previously emplaced magma body upon seal failure, are proposed as important processes leading to and contributing to the explosivity of the 2017 eruption.

30 October 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
ELEmma Liu
Emma Liu
AAAlessandro Aiuppa
Alessandro Aiuppa
AAA. Alan
A. Alan
SAS. Arellano
S. Arellano
MBMarcello Bitetto
Marcello Bitetto
KWKieran Wood
Kieran Wood
Volcanic emissions are a critical pathway in Earth’s carbon cycle. Here, we show that aerial measurements of volcanic gases using unoccupied aerial systems (UAS) transform our ability to measure and monitor plumes remotely and to constrain global volatile fluxes from volcanoes. Combining multi-scale measurements from ground-based remote sensing, long-range aerial sampling, and satellites, we present comprehensive gas fluxes—3760 ± [600, 310] tons day−1 CO2 and 5150 ± [730, 340] tons day−1 SO2—for a strong yet previously uncharacterized volcanic emitter: Manam, Papua New Guinea. The CO2/ST ratio of 1.07 ± 0.06 suggests a modest slab sediment contribution to the sub-arc mantle. We find that aerial strategies reduce uncertainties associated with ground-based remote sensing of SO2 flux and enable near–real-time measurements of plume chemistry and carbon isotope composition. Our data emphasize the need to account for time averaging of temporal variability in volcanic gas emissions in global flux estimates.

29 July 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SYSubin Yoon
Subin Yoon
AKAlexander Kotsakis
Alexander Kotsakis
SASergio L. Alvarez
Sergio L. Alvarez
MSMark G. Spychala
Mark G. Spychala
EKElizabeth Klovenski
Elizabeth Klovenski
JFJames Flynn
James Flynn
A novel technique has been developed to measure sulfur dioxide (SO2) using a modification of the existing electrochemical concentration cell (ECC) ozonesonde technology. The current sonde-based method to measure SO2 (i.e., the dual-sonde approach) involves launching two ozonesondes together, with one of the sondes having a filter to remove SO2 at the inlet. The SO2 profile is determined by taking the difference between the measurements from the two instruments. The dual-sonde method works well in typical tropospheric conditions when [O3]>[SO2] but saturates when [SO2]>[O3] and has large uncertainties in the upper troposphere and lower stratosphere that would limit its effectiveness in measuring SO2 from an explosive volcanic eruption. Due to these limitations, several modifications were made to create a single-sonde system that would directly measure SO2 (i.e., the SO2 sonde). These modifications included (1) a positively biased ECC current, (2) the addition of an O3 removal filter, and (3) the addition of a sample dryer. The SO2 sonde measures SO2 as a reduction in the cell current. There was a strong correlation (r2>0.94) between the SO2 sonde and a Thermo 43c analyzer during controlled laboratory tests and pre-flight tests. Varying humidity levels affected the SO2 sonde's sensitivity (avg =84.6±31.7 ppbv µA−1, 1σ RSD =37 %) during initial field tests, which was resolved by adding a sample dryer upstream of the O3 removal filter and pump inlet. This modification significantly reduced the variability and increased the sensitivity of the SO2 measurements (avg =47±5.8 ppbv µA−1, 1σ RSD =12 %). Field tests included measurements near Kīlauea volcano (before and during the 2018 eruption of the Lower East Rift Zone), Costa Rica's Turrialba volcano, and anthropogenic plumes from the Athabasca oil sands region of Alberta, Canada. This single-SO2-sonde system is an effective, inexpensive instrument for measuring both ground-based and vertical profiles of SO2 from anthropogenic and natural sources (i.e., volcanic eruptions) over a wide range of concentrations.

1 April 2004 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
JDJorge Andres Diaz
Jorge Andres Diaz
PDPaul Daley
Paul Daley
RMRobin Miles
Robin Miles
HRHenry Rohrs
Henry Rohrs
DPDennis Polla
Dennis Polla

19 December 2025 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
ATAnne M. Thompson
Anne M. Thompson
RSRyan Stauffer
Ryan Stauffer
DKDebra E. Kollonige
Debra E. Kollonige
JZJerald R. Ziemke
Jerald R. Ziemke
BJBryan J. Johnson
Bryan J. Johnson
BSBastien Sauvage
Bastien Sauvage
Tropospheric ozone trends are important indicators of climate forcing and surface pollution, yet relevant satellite observations are too uncertain for assessments. The assessment project TOAR-II has used multi-instrument, ground-based data for global trends over 2000–2022 (Van Malderen et al., 2025a, b). For the tropics, trends are derived from SHADOZ ozonesonde profiles (Thompson et al., 2021, “T21”; Stauffer et al., 2024) or combinations of satellite, SHADOZ and IAGOS aircraft measurements (Gaudel et al., 2024). We extend T21 that covered 1998–2019, analyzing SHADOZ data at five sites with a Multiple Linear Regression (MLR) model for 1998–2023 and reporting trends for two free-tropospheric (FT) segments, the lowermost stratosphere and the total tropospheric column (TrCOsonde). Trends for the Aura period, 2005–2023, are computed from OMI/MLS TrCOsatellite. We find the following: Extending SHADOZ analyses 4 years shows little change from T21; TrCOsonde trends are small (0.5–1 DU/decade) except over SE Asia. Annual trends for TrCOsonde and OMI/MLS TrCOsatellite agree within uncertainties at four of five sites, with the largest differences at Samoa. Sensitivity tests show the following: (a) Adding thousands of FT IAGOS profiles to SHADOZ yields little change in trends; SHADOZ sampling is sufficient. (b) Quantile Regression (QR) and MLR median trends are both near zero, but QR captures extremes (5th percentile, 95th percentile) with changes up to ±1 DU/decade (p< 0.10). (c) Twelve-year analyses for trends lead to uncertainty changes too large for an assessment. This study and Van Malderen et al. (2025a, b) provide the most reliable TOAR-II trends to date: over the past ∼ 25 years, tropical FT ozone changes have been modest, ∼ (−3–+3) %/decade, except over SE Asia.