Rui Zhang

Rui Zhang

Auto-generated profile, based on publicly available information

Rui Zhang

School of Control Science and Engineering, Shandong University, Jinan, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
CZChenghui Zhang
Chenghui Zhang
XLXiaoyan Li
Xiaoyan Li
XXXiangyang Xing
Xiangyang Xing
BZBoxue Zhang
Boxue Zhang
RZRui Zhang
Rui Zhang
Bin DuanBin Duan
Bin Duan
Modified LCL-type filter is adopted in parallel three-level inverters for high-frequency zero circulating current mitigation. However, it will generate internal resonance circulating current (IRCC) and external resonance circulating current (ERCC), which causes the output current unstable unavoidably. To address this issue, in this article, the model of IRCC and ERCC is established and analyzed. It reveals that the IRCC and ERCC are highly related to inverter-side zero sequence circulating current (ISZSCC) and common-mode voltage. Therefore, IRCC and ERCC can be suppressed by controlling the ISZSCC. To suppress the resonance currents, the ISZSCC model is first set up. Furthermore, a controller of ISZSCC is proposed and the parameters designing process of closed-loop controller are elaborated to stabilize the system based on the established model. Moreover, the resonance current suppression is achieved by adjusting the duty times of common-mode small vectors in space vector modulation. Thus, the current waveform quality and system stability are greatly improved after applying the proposed method. Finally, simulation and experiments results prove the effectiveness of theoretical analyses and proposed control strategy.

30 May 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CLChang Liu
Chang Liu
CDChunshui Du
Chunshui Du
XXXiangyang Xing
Xiangyang Xing
YJYing Jiang
Ying Jiang
RZRui Zhang
Rui Zhang
CZChenghui Zhang
Chenghui Zhang
The five-level active neutral-point-clamped (5L-ANPC) inverter has been applied to increase the power capacity of photovoltaic (PV) systems. However, this type of configuration requires to balance neutral point (NP) voltage and flying capacitor (FC) voltage properly. For the operation of the transformerless five-level inverter, another requirement is to suppress the leakage current associated with the common-mode voltage (CMV) vectors. Due to the mutually coupled issues, the conventional model predictive control (MPC) methods reported so far cannot deal with them properly at the same time. To address these problems, a novel double-vector MPC (DV-MPC) strategy with zero CMV vector is proposed in this article. First, 19 voltage vectors with zero CMV are implemented as candidate vectors. Then, for the purpose to reduce output current ripples, two voltage vectors are penalized by the cost function without weighting factors to track the reference voltage. In addition, the dwell times are optimized to further mitigate current ripples. Finally, to avoid the sharply increasing computational burden of the online iteration caused by the introduction of the second vector and its corresponding redundant switching states, a voltage-balance strategy is presented for the DV-MPC method, which can determine the suitable switching combinations directly and adapt them to the selected vectors to balance the voltages of the NP and FCs together. The effectiveness of the proposed method is verified by the simulation and experiment at the end of this article.

22 February 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZHZuohang Hu
Zuohang Hu
XXXiangyang Xing
Xiangyang Xing
CLChang Liu
Chang Liu
RZRui Zhang
Rui Zhang
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
The three-level inverter with improved LCL filter is employed in photovoltaic system to improve the power quality and suppress the leakage current. Nevertheless, this type of topology has the challenge of neutral point (NP) voltage balance, common mode (CM) resonance current suppression, and switching loss reduction. Furthermore, when a conventional discontinuous pulsewidth modulation (DPWM) method is adopted, the coupled relationship between these three control objectives becomes more complex. Due to the mutually coupled problems, the existing DPWM methods cannot achieve all control objectives at the same time. To address these issues, a modified DPWM method with NP voltage balance and CM resonance current suppression is proposed in this article. First, the conventional 60° clamping period of DPWM1 is divided into three intervals, which reduces the NP voltage ripple and the complexity of NP voltage balance control by shorting the clamping period. Then, an NP voltage limit is set to determine the control priority of NP voltage balancing and CM resonance current suppression. Finally, the clamping states and three-phase switching states are adjusted by an offset voltage according to the control priority, which can realize NP voltage balance and CM resonance current suppression simultaneously with reduced switching losses. The effectiveness of the proposed method is verified by simulation and experimental results.

29 April 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RZRui Zhang
Rui Zhang
CZChenghui Zhang
Chenghui Zhang
XXXiangyang Xing
Xiangyang Xing
ZCZhiyuan Chen
Zhiyuan Chen
XLXi Liu
Xi Liu
In parallel three-level inverters, to eliminate the undesired internal common-mode (CM) resonance circulating currents (ICMRCCs) and external CM resonance circulating currents (ECMRCCs) introduced by the improved LCL , the inverter-side CM current feedback (ICMCF) control is presented. However, since the switching frequency of the inverters is generally low in high-power applications to reduce power loss, the stability of the ICMCF control will be threatened by the delays of digital controller. In this case, the existing methods are not capable of ICMRCC and ECMRCC suppression any more. To deal with the situation, an improved CM resonance circulating current control method for high-power parallel inverters is proposed. First, the model of ICMCF with control delay is established. Second, the influences of control delay with different sampling modes on the stability of CM current control are investigated. Based on this, the allowable range of control delays and sampling frequency to keep the system stable is analyzed and deduced. Third, the multisampling mode is further extended to CM current control in the parallel inverters. The analysis results show that the stability margin and control bandwidth of the ICMCF control are significantly improved. Finally, the theoretical analysis and proposed control method are verified by simulation and experiment.

23 August 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SCShumei Chi
Shumei Chi
RZRui Zhang
Rui Zhang
GZGuanguan Zhang
Guanguan Zhang
ACAlian Chen
Alian Chen
QRQicai Ren
Qicai Ren
XXXiangyang Xing
Xiangyang Xing
Grid-forming (GFM) inverters have the advantages of voltage and frequency support in weak grid. However, unlike grid-following inverters, GFM inverters present a more challenging picture during asymmetrical voltage sag. The voltage-controlled virtual synchronous generator (VVSG) is the typical control method of GFM inverter. However, the problem of large inrush, slow response speed, and negative-sequence current control need to be carefully considered. In the existing low-voltage ride-through (LVRT) control strategies, these issues cannot be decently coped with while maintaining the ability to support the grid. In this situation, system instability and deterioration of power quality may occur. To overcome these limitations, an asymmetrical LVRT control strategy is proposed. First, the positive and negative-sequence models are established and the asymmetrical instantaneous currents are calculated. Based on this, the influences of the VVSG control method on the instantaneous negative-sequence currents are analyzed, which reveals the role of negative-sequence virtual voltage amplitude, grid phase angle, and response speed. Then, the double closed-loop control based on VVSG control method is further improved. The negative-sequence virtual voltage is compensated in the outer-loop to achieve control of negative-sequence current and inrush current. A novel passivity-based control (PBC) strategy is extended into innerloop which has fast transient response and strong robustness. Furthermore, through the transient power angle stability analysis, the improvement of the transient margin is proved. Finally, simulation and experimental results verify the effectiveness of the proposed method.

20 August 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SCShumei Chi
Shumei Chi
RZRui Zhang
Rui Zhang
ACAlian Chen
Alian Chen
CCCheng Cheng
Cheng Cheng
SSShumin Sun
Shumin Sun
YCYan Cheng
Yan Cheng
Grid-forming inverters (GFMIs) are increasingly being integrated into grid-connected systems dominated by grid-following inverters (GFLIs) to enhance the stability of weak grids. However, the capability of traditional grid-forming control to enhance system stability remains limited. Specifically, when the output power of GFLI increases, the hybrid system consisting of GFMI and GFLI remains susceptible to oscillations and potential instability. To address these limitations, the interaction stability of the hybrid system is comprehensive analyzed and a passivity-enhanced oscillation suppression method is proposed. First, a decomposition impedance model is established to analyze the interaction mechanisms between GFLI and GFMI, as well as the impact of varying power levels. The analysis reveals that increasing the output power of GFMI does not inherently improve its ability to suppress system oscillations. Subsequently, a coupling term responsible for oscillations in the hybrid system is identified and a novel power-adaptive active damping is introduced into the GFMI control to enhance system passivity. In this case, the oscillation of hybrid system can be effectively suppressed under varying power levels and grid impedances. Finally, the experimental results verify the effectiveness of the proposed method.