Cheng Cheng

Cheng Cheng

Auto-generated profile, based on publicly available information

Cheng Cheng

School of Control Science and Engineering, Shandong University, Jinan, China

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SCShumei Chi
Shumei Chi
RZRui Zhang
Rui Zhang
ACAlian Chen
Alian Chen
CCCheng Cheng
Cheng Cheng
SSShumin Sun
Shumin Sun
YCYan Cheng
Yan Cheng
Grid-forming inverters (GFMIs) are increasingly being integrated into grid-connected systems dominated by grid-following inverters (GFLIs) to enhance the stability of weak grids. However, the capability of traditional grid-forming control to enhance system stability remains limited. Specifically, when the output power of GFLI increases, the hybrid system consisting of GFMI and GFLI remains susceptible to oscillations and potential instability. To address these limitations, the interaction stability of the hybrid system is comprehensive analyzed and a passivity-enhanced oscillation suppression method is proposed. First, a decomposition impedance model is established to analyze the interaction mechanisms between GFLI and GFMI, as well as the impact of varying power levels. The analysis reveals that increasing the output power of GFMI does not inherently improve its ability to suppress system oscillations. Subsequently, a coupling term responsible for oscillations in the hybrid system is identified and a novel power-adaptive active damping is introduced into the GFMI control to enhance system passivity. In this case, the oscillation of hybrid system can be effectively suppressed under varying power levels and grid impedances. Finally, the experimental results verify the effectiveness of the proposed method.


16 January 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WWWei Wang
Wei Wang
Tong LiuTong Liu
Tong Liu
SCShijie Cheng
Shijie Cheng
CCCheng Cheng
Cheng Cheng
SNShaokun Niu
Shaokun Niu
ACAlian Chen
Alian Chen
The hybrid modular dc transformer (HMDCT), combining the series resonant dual active bridge (SR-DAB) and phase-shift dual active bridge (PS-DAB), is very suitable for dc bus interlinking applications with bidirectional controllability and high efficiency requirements. However, the coupling between SR-DAB and PS-DAB sub-modules results in a strongly nonlinear dynamic behavior, which in turn poses challenges in instantaneously and coordinately regulating each sub-module to achieve a fast dynamic response of the HMDCT total output. To solve this problem, this article proposes the HMDCT nonlinear input–output large-signal model and a state feedback linearization-based load-current feedforward control (LCFC) strategy. The proposed strategy constructs a linear, load-independent, and easily controllable input–output relationship, while achieving accurate observation of physically nonexistent feedback states in the nonlinear system without relying on complex sampling algorithms and circuits. The system stability including controlled states and uncontrolled internal dynamics is proved, providing a theoretical basis for practical applications. Furthermore, to reduce implementation complexity, the proposed strategy is simplified into improved LCFC form with easily understood physical meaning and less computational effort. Experimental results on a HMDCT prototype show that the proposed strategy significantly improves the dynamic performance in bidirectional operating directions, compared to the conventional feedforward-based strategy.

1 January 1992
Verified
Conference Paper
Closed access
CCCheng Cheng
Cheng Cheng
STStellini
Stellini
PEPearah
Pearah
CCChen Chen
Chen Chen
MOMoy
Moy
HSHsieh
Hsieh
We report on the fabrication of the first AlGaInP visible laser diodes with multiple quantum wire active regions formed in situ during gas source molecular beam epitaxy. No regrowths or ex situ fabrication procedures were employed in the formation of the quantum wires. Quantum wires with cross-sectional dimensions of approximately 50 AA*120 AA were achieved with a linear wire density of 100/ mu m. Broad area stripe geometry lasers with contact stripe oriented in the [110] and [110] directions had an anisotropic threshold current density ratio of more than 3.75. Lower threshold current densities were obtained for lasers with contact stripes in the [110] direction, perpendicular to the quantum wires. Strong dependence of electroluminescence polarization on contact stripe direction was observed with a TE/TM intensity ratio of over 275.<>

6 October 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MWMingyue Wang
Mingyue Wang
ACAlian Chen
Alian Chen
YHYaopeng Huang
Yaopeng Huang
XPXianzhe Pang
Xianzhe Pang
CCCheng Cheng
Cheng Cheng
Tong LiuTong Liu
Tong Liu
The Andronov–Hopf virtual oscillator control is a grid-forming control strategy based on instantaneous current feedback, which provides voltage and frequency support in weak grids. However, the unavoidable power coupling and inherent inaccuracies in power tracking control lead to steady-state errors and dynamic oscillations, which severely restrict the power delivery and the grid support capability. Therefore, this article proposes an optimized loop-shaping-based power control (OLPC) strategy to ensure system stability. First, to address the inability of the relative gain array to evaluate feedback dynamics, a closed-loop transfer function array is developed. It explicitly reveals two limitations: failure to achieve power decoupling and amplification of reactive power tracking errors. Subsequently, the objectives of OLPC are formulated in the frequency domain using bandwidth design specifications. Then, the optimal parameters are obtained by reformulating the parameter design problem as a convex optimization problem. Compared to the virtual inductor methods, the OLPC exhibits superior wide-frequency power decoupling, more accurate reactive power tracking, and faster power response. Finally, the theoretical analysis and proposed method are validated through experiments.

24 June 2025 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
HZHang Zhang
Hang Zhang
Tong LiuTong Liu
Tong Liu
YHYaopeng Huang
Yaopeng Huang
ACAlian Chen
Alian Chen
GZGuanguan Zhang
Guanguan Zhang
YLYong Li
Yong Li
For high-quality grid connections in distributed generation, the robustness and transient performance of grid-tied inverters (GTI) under various operating conditions are crucial. This article presents a novel model-free adaptive synergetic control (MFASC) approach, which can significantly improve the robustness and transient performance of GTI. To enhance the robustness and adaptability of GTI, and to avoid the effects of unmodeled dynamics, a compact form dynamic linearization model based on the system input/output information is established. Subsequently, in order to improve the response speed, a synergetic control law is designed by utilizing the rapid convergence of differential equations. To further enhance the dynamic performance, an overshoot suppression strategy is designed to suppress the dynamic overshoot through ensuring Lipschitz condition, and a T-factor adaptive law is designed to adjust the response speed and system oscillation by dynamically changing the T parameter of the MFASC. Finally, the MFASC method is applied to the current control of GTI, and the validity is verified through simulation and experiment.