Ao Chen

Ao Chen

Auto-generated profile, based on publicly available information

Ao Chen

School of Advanced Manufacturing, Nanchang University, Nanchang 330031, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in Composite Structures
Verified
Journal Article
Closed access
JCJincheng Cao
Jincheng Cao
FWFangwen Wu
Fangwen Wu
SLSong Lei
Song Lei
XFXiangyan Fan
Xiangyan Fan
Liu LaijunLiu Laijun
Liu Laijun
ACAo Chen
Ao Chen

7 August 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiangQian YU
XiangQian YU
CXChiJie Xiao
ChiJie Xiao
Si LiuSi Liu
Si Liu
Qiugang ZongQiugang Zong
Qiugang Zong
YQYaNan Qu
YaNan Qu
SSSiPei Shao
SiPei Shao
AC vector magnetometers have recently become increasingly widespread. The calibration of AC vector magnetometers before use is critical. Based on traditional ellipsoid fitting, which is suitable for calibrating DC vector magnetometers, a method suitable for calibrating AC vector magnetometers is presented. Simulation analysis and experimental verification demonstrate that this method is effective in calibrating AC vector magnetometers, including scaling factors, angular misalignments and offset errors.

29 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiangQian YU
XiangQian YU
YWYongFu Wang
YongFu Wang
CXChijie Xiao
Chijie Xiao
Si LiuSi Liu
Si Liu
Qiugang ZongQiugang Zong
Qiugang Zong
SSSiPei Shao
SiPei Shao
Magnetic sensor array has become increasingly widespread in use. Because of the manufacturing process, magnetic sensors in an array inevitably experience calibration factor errors. Therefore, the calibration of a magnetic sensor array is very important before use. However, it lacks explicit and quantitative measures on how to calibrate a magnetic sensor array. By using magnetic fields produced by a standard magnetic source at different locations, a practicable method was proposed based on the least-squares method to calibrate a magnetic sensor array. The dimensions of sensor array are about 50×50×50 cm 3 and the level of magnetic field aiming to be measured is ~nT. Both the simulation and experimental results demonstrate that the proposed method is effective in identifying the calibration factor of a magnetic sensor array.

4 January 2021 in Journal of Geophysical Research: Space Physics
Verified
Journal Article
Open access
PDF file
ACAo Chen
Ao Chen
CYChao Yue
Chao Yue
HCHongfei Chen
Hongfei Chen
QZQiugang Zong
Qiugang Zong
SFSuiyan Fu
Suiyan Fu
JRJie Ren
Jie Ren
Ring current decay during storm recovery phase may be affected by different loss processes. In this study, we have investigated the lifetimes of ring current ions (H+ and O+) of energies from 1 keV to several hundred keV at L shell from 3 to 6 during the storm recovery phase through a statistical survey. The observational data of 48 geomagnetic storms from March 2013 to May 2019 are collected based on Van Allen Probe observations. We find that (1) the observed lifetimes of H+ and O+ in general increase with L shell and (2) the lifetimes of H+ is short than that of O+ when E < ∼50 keV while the situation is reversed when E > ∼50 keV. In addition, we have made use of the charge exchange theory, combined with previous experimental results on the charge exchange cross section and two distribution models of neutral hydrogen atoms in the exosphere, so as to directly estimate the ring current ions decay caused by charge exchange mechanism only. Through the comparison between the model predictions of charge exchange lifetime and the observed lifetimes, we find that (3) the observed lifetimes are in general consistent with model results, which confirms that charge exchange is a dominant loss mechanism of ring current ions during storm recovery phase.

17 February 2024 in Engineering Failure Analysis
Verified
Journal Article
Closed access
YHYun Hu
Yun Hu
YLYongqing Liu
Yongqing Liu
JXJiangjing Xi
Jiangjing Xi
JJJun Jiang
Jun Jiang
YWYouquan Wang
Youquan Wang
Kamran NikbinKamran Nikbin
Kamran Nikbin

30 July 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SSSiyu Song
Siyu Song
HCHongfei Chen
Hongfei Chen
XYXiangQian YU
XiangQian YU
ACAo Chen
Ao Chen
WSWeihong Shi
Weihong Shi
YYYuguang Ye
Yuguang Ye
The internal charging effect may lead to electrostatic discharges (ESDs) for Geostationary Earth Orbit (GEO) and Middle Earth Orbit (MEO) satellites. This is due to the high-energy electrons that deposit in the dielectrics of satellites. The properties of the dielectrics such as permittivity and dark conductivity dominate this effect. This may contribute to the ESD risk of long-lifetime satellites if these properties change with the increase of electron dose. Two general materials, Polyimide (PI) and FR4 Epoxy Glass Cloth (FR4), were chosen as samples to study by experiments with different doses. The results show that the permittivity of PI and FR4 decreased as the dose increased while the dark conductivity increased. Numerical simulation evaluates the electron dose and the ESD risk of dielectrics under the electron environment of a specific MEO electron spectrum. The results show that the decrease of permittivity and the increase of dark conductivity will shorten the time constant of internal charging. The quicker build-up of electric field will increase the ESD risk if it exceeds the breakdown threshold.