27 February 2018 in IEEE Transactions on Power Electronics
A 1270 Hz resonance occurred between ±350 kV/ 1000 MW Luxi back-to-back voltage source converter based high-voltage dc transmission (VSC-HVDC) converter and the 525 kV ac grid after disconnection of several ac transmission lines. To understand the resonance and find a solution, the impedance-based stability analysis model considering different equipment is first established. Then, the resonance is analyzed and repeated in the simulation based on the established model. The system stability can be judged by the ratio of grid impedance to the equivalent impedance of all parallel-connected equipment with the converter. To evaluate the occurrence and risk of resonance, the frequency range where the impedance has a negative-real-part has been searched and studied. In order to narrow the negative-real-part region to avoid potential resonance, solutions such as control strategy improvement and passive or active impedance adapter may be applicable and are discussed. For a complex system containing various equipment, the equipment can be divided into several subsectors to avoid modeling all possible combinations of equipment, which can be exhausting. And analysis has shown sufficient but not necessary condition to stabilize the system is to avoid the negative-real-part region in each sector.
4 September 2018 in IEEE Transactions on Power Delivery
To ensure the continuous operation of the VSC-MTDC, there has been much concern regarding how to isolate the single-pole earth fault by means of protective relaying. However, when the boundary components are not on the DC transmission lines, conventional main protections for the HVDC systems perform less satisfactorily. To solve this problem, a local measure-ment-based ultra-high-speed main protection is proposed in this manuscript. The proposed method is achieved by the co-operation of the single-end directional start-up criterion and the surge arrival time difference between the 0-mode and 1-mode traveling waves. According to the simulation results, the proposed method has satisfactory performance against internal faults and is quite reliable in external fault and operating condi-tion changes. Meanwhile, the reach is also wide enough to cover most of the protected line. Comparison studies are also con-ducted among the proposed protection and three types of exist-ing protection schemes, highlighting the advantages of the pro-posed protection in terms of selectivity, operating speed and resistive tolerance.
4 September 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Junction temperature is a key parameter for the safe operation of power semiconductor devices in power electronic systems. However, it’s difficult to forecast the accurate thermal stress of device in field use. Consequently, engineers tend to use higher rated devices to maintain excessive margin, resulting in higher cost. In this paper, a transient 3D thermal modelling method for IGBT modules is proposed to obtain accurate temperature distribution considering uneven power losses and cooling conditions. The analytical model of uneven switching energy losses among the parallel IGBT chips in modules are built up according to the analysis on device simulation results. The effect of uneven cooling conditions on temperature distribution in IGBT modules is considered by thermal-fluid co-simulation. Further, a hybrid simulation strategy is proposed to obtain the transient thermal behavior in three dimensions. Through appropriate interface design, the power loss model is connected with finite element model to achieve field-circuit co-simulation with multiple time steps, which takes full consideration of the multi-physical coupling effects among power loss, temperature and flow fields. Finally, the thermal stresses of IGBT modules under different operating conditions are forecasted by the proposed method.
5 August 2019 in Journal of Electrical Engineering & Technology