10 August 2005 in Applied Physics Letters
Two-dimensional resonance frequency mapping in the ultrasonic atomic force microscopy was applied to the investigation of the ferroelectric domain structure in lead zirconate titanate ceramics. This method can visualize the stiffness anisotropy due to the differently oriented domains. Moreover, the significant stiffness reduction at the ferroelectric domain boundary was discovered. The disorder of the lattice, the ability of the switching of the domain, and the reduction of the piezoelectric stiffening are possible explanations. The implication of this work is the characterization of novel functional materials on nanoscale and the nondestructive evaluation of the microelectromechanical systems and nanotechnology devices.
14 September 2020 in Applied Physics Letters
Ultrasonic phased-array (PA) systems have been widely adopted in the field of nondestructive evaluation for material characterization and imaging of internal defects. Whereas many defects exhibit complex three-dimensional structures, most PA systems provide only two-dimensional images. In this Letter, we demonstrate the ability to create high-resolution 3D images of internal defects using a PA system based on a piezoelectric and laser ultrasonic system (PLUS). The PLUS combines a piezoelectric transmitter to insonify the structure to be inspected with a laser Doppler vibrometer to create a matrix array of receiver points without contact. The small size of the laser beam results in an ultra-multiple number of elements on the order of thousands, which is impossible to achieve with a conventional piezoelectric matrix array transducer. An emission from a piezoelectric transmitter compensates for the intrinsically low sensitivity of a laser Doppler vibrometer. After formulating the 3D imaging algorithm of the PLUS, we demonstrate that the PLUS with 4096 receiving points (i.e., 64 × 64 points) achieves high-resolution 3D imaging in a specimen with a flat bottom hole. We also visualize the complex structure of stress corrosion cracking. We believe that the 3D imaging capability of the PLUS may open up new avenues to the accurate evaluation of material strength, the identification of the types of defects, and the elucidation of the mechanisms of defect initiation.
1 July 2008 in Japanese Journal of Applied Physics
8 June 2017 in Japanese Journal of Applied Physics
A ball surface acoustic wave (SAW) trace moisture analyzer (TMA) was applied to measuring the adsorption and desorption (AD) characteristics of a stainless steel tube. For the first time, two-frequency measurement for precise temperature compensation was attempted at intervals of 3 s using a burst waveform undersampling circuit. We succeeded in measuring the variations of moisture transit time and dry-down dynamics caused by inner surface treatments such as bright annealing (BA), electropolishing (EP), and electrochemical buffing (ECB) using a sample-tube length of only 100 mm at a flow rate of 0.1 L/min. Net moisture adsorption was evaluated from the measured adsorption subtracted by the background adsorption. As a result, it was found that the adsorption on the ECB tube was smaller than those on EP and BA tubes by 1/3 and 1/4, respectively, at a baseline concentration of 13 ppbv. From these results, it was demonstrated that the ball SAW TMA could be used for measuring the AD characteristics of stainless steel tubes with various surface treatments.
1 July 2012 in Japanese Journal of Applied Physics
1 January 2014 in MATERIALS TRANSACTIONS
In manufacturing process of semiconductor, blue light emitting diode (LED), and lithium ion battery, detection and monitoring of trace water vapor (<1 µmol/mol) are significantly important techniques. We have been researching about detection of trace water vapor with high speed and sensitivity by using ball surface acoustic wave (SAW) sensor. In this paper, we tried to detect trace water vapor by coating silicon oxide (SiOx) on ball SAW sensor using sol–gel method. It was confirmed that SiOx-coated ball SAW sensor could detect water vapor in a wide range from −95 to 0°C in frost point (0.035–6.0 × 103 µmol/mol in concentration) and its response time to frost point change from −70 to −60°C was one half of that of a chilled-mirror hygrometer.