The optimal sizing and location of electric vehicle charging station (EVCS) integrated with distributed generation (DG) in the distribution network are the subject of this study. In modern electric power systems, the integration of EVCS and DG must be carefully planned. Inappropriate sizing and location of EVCS can cause network overload, increase power losses, and allow for voltage variations outside the standard. This study adopts a reference distribution network that is representative of a typical business distribution network in a metropolitan city in Indonesia. To resolve the issue of determining the size and location of EVCS, the hybrid genetic algorithm-modified salp swarm algorithm (HGAMSSA) optimization method with multi-objective function is implemented. There are three scenarios used when determining the size and placement of EVCS. In the first scenario, the EVCS comprises chargers at levels 1, 2, and 3, with DG integration. In the second scenario, EVCS is comprised of level 2 and level 3, with DG integration. While in the third scenario, EVCS only consists of level 3 chargers with DG integration. The simulation results indicate that network utilization can be optimized at 79.00%, 75.53%, and 76.37% when electric cars (EV) operate in grid to vehicle (G2V) mode, compared to a base load of 29.46%. In vehicle to grid (V2G) mode, the energy supplied by the electric vehicle (EV) via the EVCS is 0.91 MWh. Additionally, the distribution network receives 10.036 MWh of electricity from rooftop photovoltaic (PV).
This study utilized a newly developed hybrid algorithm to ascertain the most favorable site for the installation of electric vehicle charging stations (EVCs). Random installation of EVCs may cause voltage disturbances, power quality disturbances and power losses in the distribution network. The hybrid genetic algorithm-modified salp swarm algorithm (HGAMSSA) was used to determine the optimal EVCs placement in the distribution network by considering power losses, network capacity and voltage regulation. HGAMSSA is a combination of GA and MSSA. In the first stage, the GA method distributes the population randomly and the second stage crosses the membership between dimensions. In the third stage, MSSA processes the best population from the GA to determine the best objective function. The HGAMSSA incorporates Optimal Power Flow (OPF) calculations based on Newton-Raphson. The OPF simulation uses a modified 20kV IEEE 33 bus distribution network. For validation, HGAMSSA was compared with four different algorithms: GA, PSO, SSA, and MPSO. There are three test scenarios with populations of 100, 50, and 20. As a result, the power loss generated as the best objective function wase 0.15715 MW. When the population is 100, HGAMSSA has the fastest iteration (5 th ) in achieving the best objective function compared with MPSO (13 th ) and SSA (17 th ). Furthermore, the best objective function can only be achieved by HGAMSSA when the populations are 50 and 20. This shows that HGAMSSA can explore and exploit populations performance to identify the optimal objective function.
The use of technology to optimize electricity from photovoltaic (PV) farms is growing. Partial shading often occurs in PV farms owing to cloud movement or dust on the PV modules. Therefore, estimating shading patterns is essential as preliminary information for subsequent power optimization. This paper proposed an artificial neural network (ANN) to estimate the pattern of partial shading conditions. Simulation using a 160kW peak PV farm consisting of 600 modules in a 20 series - 30 parallel configuration is conducted in this research. The proposed technique measures each string's current and the substring's voltages. The Matrix of the current and voltages represents the shaded area of the PV farm and is used as a dataset. When partial shading (PS) occurs on the PV farm, the ANN model receives input data from current and voltage. Then, the trained ANN processes the input to estimate shading patterns. Assessment of the estimation results was carried out to determine the shaded PV module ratio and the shading strength. Comparative analysis explains that the proposed method outperforms other techniques such as Multiple-output Support Vector Regression (M-SVR), ANN with Levenberg–Marquardt (LM) training, and conventional backpropagation networks. In a typical shading condition, the best estimation depicts the accuracy of the shaded PV module ratio as 97% and shading strength as 98%. While the low accuracy results in the shaded PV module ratio as 94% and shading strength of 96%. Thus, the proposed technique can satisfactorily estimate the pattern caused by clouds in large-scale PV farms.
1 February 2025 in Indonesian Journal of Electrical Engineering and Computer Science
The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.
Currently, electric vehicles (EV) have become more popular in research because of issues of the environmental pollution and the running out of fossil fuel. This research presents a strategy of independent speed steering control for two front in-wheel BLDC motors while an EV drives on a straight road as well as on a curved road. When the EV runs on a straight road, each front wheel has the same rotating speed. However, on a curved road, the outer wheel has the rotating speed higher than the inner wheel. Ackermann-Jeantand steering model is used to determine the reference speed for each front wheel of the EV during turning motion when a certain steering angle and EV speed are inputted. The fuzzy logic controller (FLC) has been designed to control the speed of each motor to reach the desired speed. Hysteresis current controller is introduced to generate the switching signals for each switch device in the power inverter. A Graphical User Interface (GUI) is created in MATLAB to control the overall system. Three different cases of simulation have been done and the results are satisfying with the response. The results demonstrated that the control system has worked properly.
In this paper, we present a modified battery testing scheme using dc-dc bidirectional cuk converter. This converter is addressed to average current mode control in order to get constant current at input or output side of converter for battery testing purpose. Battery type used in this experiment is valve regulated lead acid (VRLA) with rating of 12 V and 7.2 Ah. In this experiment with the new proposed battery testing system we will conduct two testing. First, the discharge testing to get battery discharge characteristics. Second, the charge-discharge cycle testing to clarify the ability of state of charge (SoC) estimation method with coulomb counting to predict the SoC of battery with comparison of open circuit voltage method that have good accuracy in predicting the SoC of battery. The result of coulomb counting obtain accuracy of 98,13% in predicting the SoC of battery.