The load level for each period in the distribution network can be considered non-identical due to the increasing demand for loads and the bigger distribution network. The main problem in the transmission and distribution network system is power losses and voltage profiles, affecting the quality of service and operating costs. This study compares the reconfiguration of the network using exhaustive search techniques and particle swarm optimization (PSO) algorithms on the IEEE 33 bus distribution network system. The study’s results compare the study of power flow before and after network reconfiguration, which is a decrease in the value of power losses from 202.7 kW to 139.6 kW. Then voltage profile improved from 91.309% to 93.782%. The simulation results also found that this reconfiguration can improve the system voltage profile, which initially contained 21 buses outside the standard limits of IEEE Std 1159-1995 to 7 buses.
1 August 2023 in International Journal of Electrical and Computer Engineering (IJECE)
In the operation of the power transformer, several maintenance efforts must be made to ensure the condition of the transformer is in good condition. The problems that usually arise are a thermal failure and electrical failure. The use of insulating media such as transformer oil and transformer insulation paper can be disrupted by this failure. Dissolved gas analysis, which identifies the types and concentrations of dissolved gas in transformer oil, can reveal details on fault indicators in power transformers (DGA). In this study, we used the interpretation of the IEEE std 2008-C57.104 (total dissolved combustible gas (TDCG), key gas, Rogers ratio method), the interpretation of IEC 2015-60599 (Duval triangle and basic gas ratio method), and the IEEE Std 2019-C57.104 interpretation (Duval pentagon method). The outcome of the DGA test is used to determine the conditions and indications of disturbances in the transformer for power. Using various gas analysis techniques also impacts the outcome of the fault indication. This variation has affected the types of gas used in the computation and the gas concentration limit value estimation. After the gas analysis, it was found that the oil purification process was also proven to reduce the concentration of combustible gases.
1 August 2019 in Journal of Physics D: Applied Physics
A numerical simulation was conducted to obtain temperature and gas flow fields in tandem-type inductively coupled thermal plasma (tandem ICTP). Tandem ICTP is formed using two coil currents (upper coil and lower coil) in a single plasma torch, that was already developed for nanoparticle synthesis. The temperature distribution of the tandem ICTP and evaporation of feedstock Ti powder were obtained for different gap lengths between the upper and lower coil and coil turn numbers. Results indicate that increasing the gap length between the upper and lower coil produces two separately controlled high-temperature areas in tandem ICTP. This result suggests that tandem ICTP provides a temperature field that is favourable for particle evaporation of injected particles while maintaining ICTP in the upper region of the plasma torch for stable operation.
Numerical calculation was conducted to study the gas flow fields and temperature distribution in Ar inductively couple thermal plasma (ICTP) with titanium (Ti) powder injection. Influence of sheath gas flow rates at 90 L/min, 80 L/min and 70 L/min was investigated on the thermal plasma temperature in the torch. Results indicated that higher sheath gas flow rate raises the axial temperature and gas flow velocity in the thermal plasma
1 February 2025 in Indonesian Journal of Electrical Engineering and Computer Science
The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.
1 December 2022 in Indonesian Journal of Electrical Engineering and Computer Science
Fossil energy sources are dwindling. It is necessary to develop alternative energy sources for future energy. The solar cell is an alternative energy that can be used in Indonesia. The current challenge is utilizing solar panels for the best possible power production. This research gives the solution to design an increase in solar cell output power by using mirrors, cooling, and a double-axis solar tracking control system. The results show that using a mirror, cooling, and double-axis solar tracking produces optimal output power with a current and power are 2.43 amperes and 40.3 watts, respectively. Meanwhile, several factors can affect this solar panel's efficiency. Specifically, the amount of solar radiation that the solar panel can receive depends on the climate on the day and location of the research and the solar panel's dimensions.