Timo Schröder

Timo Schröder

Auto-generated profile, based on publicly available information

Timo Schröder

Max-Planck-Institute for Plasma Physics 1 , Greifswald, Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2019 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
BGBenedikt Geiger
Benedikt Geiger
TWThomas Wegner
Thomas Wegner
CBCraig D Beidler
Craig D Beidler
RBRainer Burhenn
Rainer Burhenn
BBBirger Buttenschön
Birger Buttenschön
TTthe W7-X team
the W7-X team

1 July 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TWTh. Wegner
Th. Wegner
BGB. Geiger
B. Geiger
FKF. Kunkel
F. Kunkel
RBR. Burhenn
R. Burhenn
TST. Schröder
T. Schröder
WTW7-X Team
W7-X Team
We present a detailed overview and first results of the new laser blow-off system on the stellarator Wendelstein 7-X. The system allows impurity transport studies by the repetitive and controlled injection of different tracer ions into the plasma edge. A Nd:YAG laser is used to ablate a thin metal film, coated on a glass plate, with a repetition rate of up to 20 Hz. A remote-controlled adjustable optical system allows the variation of the laser spot diameter and enables the spot positioning to non-ablated areas on the target between laser pulses. During first experiments, clear spectral lines from higher ionization stages of the tracer ions have been observed in the X-ray to the extreme ultraviolet spectral range. The temporal behavior of the measured emission allows the estimate of transport properties, e.g., impurity transport times in the order of 100 ms. Although the strong injection of impurities is well detectable, the global plasma parameters are barely changed.

29 January 2020 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
PDF file
CBC Brandt
C Brandt
JSJ Schilling
J Schilling
HTH Thomsen
H Thomsen
TBT Broszat
T Broszat
RLR Laube
R Laube
TST Sieber
T Sieber
The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up–down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is ≈200 kHz and the sensitive energy range is approximately 1–12 keV. The measurements indicate the up–down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.

1 April 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
APA. Pandey
A. Pandey
SBS. Bohm
S. Bohm
ACA. Carls
A. Carls
CCC. Cordes
C. Cordes
MEM. Endler
M. Endler
WTW7-X Team
W7-X Team
The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

1 March 2012 in Europhysics Letters
Verified
Journal Article
Closed access
TST. Schröder
T. Schröder
OGO. Grulke
O. Grulke
TKT. Klinger
T. Klinger

3 January 2014 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
TST Schröder
T Schröder
OGO Grulke
O Grulke
TKT Klinger
T Klinger
RBR W Boswell
R W Boswell
CCC Charles
C Charles