The residual flux (RF) in three-phase transformers can dramatically increase the inrush current when the transformer is energized. The RF can also severely interfere with diagnostic tests, such as the frequency-response analysis (FRA) test. However, there is no effective method to fully eliminate the RF in the core of a three-phase transformer. Additionally, there are few relevant experimental reports on methods to accurately measure the RF in the magnetic core of a three-phase transformer; this measurement is important for evaluating the demagnetization results and phase-controlled switching strategies. Hence, this paper proposes an improved flux-controlled variable frequency-constant voltage (VFCV) strategy combined with core flux equalization to simultaneously eliminate and measure the RF of a three-phase transformer core by applying a low-power electronic device. The effectiveness and accuracy of the proposed strategy are validated by the simulation and experimental tests of a 10 kV distribution transformer and a 500 kV delta-connection three-phase separating transformer. The results reveal that the RF can be eliminated to less than 1 % of the knee point flux and that the measurement is fairly accurate.
16 July 2025 in IEEE Transactions on Power Delivery
Power transformers are crucial components that contribute to the overall stability and reliability of the power grids. Due to hysteresis effects, residual magnetism can remain in the transformer’s iron core after switching off. This residual magnetism can cause excitation inrush when the transformer is re-energized, potentially damaging the transformer, threatening grid stability, and increasing the risk of power grid failure. To address this issue effectively, a universal, reliable, and fast method for eliminating residual magnetism is needed. This paper proposes an energy storage oscillation method for eliminating remanent magnetization in large power transformers. The method’s effectiveness and speed are validated through simulations and experimental comparisons with various demagnetization techniques. The results confirm that this method is not only rapid but also highly effective in practical applications.
With the expanding application of pulsed power technology in plasma physics, industrial processing, and defense and military weapon systems, the demand for compact and high-efficiency pulse generators has been steadily increasing. Conventional stacked Blumlein pulse generators (SBPGs) often suffer from limited voltage gain and low stacking efficiency due to electromagnetic coupling among transmission lines or parasitic coupling to ground. This paper presents a novel high-efficiency stacked Blumlein pulse generator that integrates a multi-stage Boost DC–DC converter with a magnetic coupling suppression method. The proposed approach directly embeds multiple nanocrystalline magnetic rings into a matching load or a small pre-load resistor, effectively increasing the coupling impedance and minimizing parasitic energy leakage. Meanwhile, the multi-Boost topology raises the charging voltage of each coaxial stage to several times the supply voltage, thereby achieving both enhanced voltage gain and improved stacking efficiency. Simulation and experimental results demonstrate that under a 400 V supply, each stage is charged to approximately 1.06 kV, producing an output voltage of 10 kV with a 49 ns rise time, 118 ns pulse width, and a stacking efficiency of 94.3%. This represents a 20% improvement over the case without the proposed method. The developed generator exhibits high gain, high efficiency, and wide tunability (20 kHz – 1 MHz), offering a promising solution for next-generation compact, solid-state, and high-repetition-rate pulsed power systems.
1 July 2026 in IEEE Transactions on Power Electronics
Grid-forming (GFM) voltage-source converters (VSCs) are expected to provide inertia power support during grid-frequency disturbances and grid-voltage phase-angle jumps. However, the existing synchronization control methods have unsatisfactory performance to control the GFM VSCs to provide the maximum inertia power support while achieving robust synchronization and DC-link voltage control during these transient events. To bridge this gap, this paper proposes a novel unified synchronization control (USC) strategy that integrates an active power compensator with a DC-link voltage compensator through a parallel configuration. With the proposed USC, the GFM VSC can autonomously and seamlessly switch its operation between two modes: a voltage-controlled DC-side source (VC-DCS) mode when the DCS current is within the limit and a current-controlled DCS (CC-DCS) mode when the DCS current reaches the limit, while providing the maximum inertia power support. Compared to the state-of-the-art power synchronization control (PSC) and DC-link voltage synchronization control (DVSC) methods, the USC significantly enhances the transient oscillation damping as well as synchronization and DC-link voltage stability. A parameter design methodology for the USC is presented. Finally, the superiority of the proposed USC over the PSC and DVSC is validated by a loop-gain evaluation using simulation as well as grid-frequency step change and grid-voltage phase-angle jump tests using a GFM VSC hardware testbed.