Fuqiang Ren

Dr. Fuqiang Ren

School of Electrical Engineering, Shandong University, Jinan, Shandong, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Fuqiang RenFuqiang Ren
Fuqiang Ren
ZKZhaoyang Kang
Zhaoyang Kang
SJShengchang Ji
Shengchang Ji
QLQing-quan Li
Qing-quan Li
Fault localization and severity evaluation of transformer winding is crucial for its mechanical condition assessment. Ladder network synthesis of winding entity based on its frequency response analysis data is an elegant solution to this problem. This article proposes a generic method for high-frequency (HF) ladder network synthesis of winding in different mechanical conditions for its fault diagnosis. The simplified HF network used in the synthesis process is first built. Afterward, the synthesis algorithms with high precision and efficiency and the mathematical model for normal HF ladder network are elaborated. Further, the synthesis method for defective network is proposed to locate the winding fault positions and evaluate their severities. Finally, the network synthesis method is applied on a distribution transformer, with the fact that the obtained network components comply with all the constraints and the diagnostic results also match well with the actual mechanical conditions of winding, which verifies its feasibility and accuracy.

2 June 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Fuqiang RenFuqiang Ren
Fuqiang Ren
HZHongru Zhang
Hongru Zhang
YLYong Liu
Yong Liu
SJShengchang Ji
Shengchang Ji
QLQing-quan Li
Qing-quan Li
Ladder network synthesis is very significant for winding fault diagnosis within transformer. To synthesize the network reversely based on the measurable frequency response analysis (FRA) data is the only applicable way. To date the iron core and non-tested winding, which result in the frequency-dependent network components and multiple ladders in some frequency ranges, are usually not considered in the reverse process and thus the synthesis precision is largely limited. This paper proposes to synthesize multiple ladder networks in different frequency regions to handle this problem. Firstly, the sensitivities and frequency-dependent features of network components are analyzed, based on which the topology and components of the networks in diverse frequency ranges are determined afterwards. Further, the network synthesis strategies in different frequency ranges are elaborately designed. Finally, the synthesis method is applied on a distribution transformer successfully, with the fact that the extracted network parameters meet all the constraints and its FRA curve matches well with the measured one. An intact method of multiple-network synthesis for transformer winding in wide frequency range, considering the iron core and non-tested winding, is offered in this paper.

30 July 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ZLZe Li
Ze Li
DHDongxin He
Dongxin He
Fuqiang RenFuqiang Ren
Fuqiang Ren
SLShuqi Li
Shuqi Li
HWHongbin Wu
Hongbin Wu
QLQing-quan Li
Qing-quan Li
To investigate the effect of temperature on the internal electric field distribution and oil streamer discharge development under AC-DC composite voltage, the dielectric parameters of insulating oil and insulating pressboard at different temperatures are measured experimentally. The nonlinearity of dielectric parameters with temperature is compared and analyzed in terms of its effect on electric field distribution. Additionally, based on the bipolar carrier transport model and drift-diffusion model, the influence of temperature on the discharge development process is simulated and studied. The results indicate that considering the non-linear temperature dependence of dielectric parameters, the electric field strength in oil is positively correlated with the ratio of dielectric constants of insulating pressboard to that of insulating oil, and negatively correlated with the ratio of conductivity. There is an opposite law for insulating pressboard. Increasing temperature exponentially enhances charge mobility by altering conductivity which exacerbates discharge development process. The attraction of insulating pressboard to streamer discharge is positively correlated with the difference in dielectric constants between oil and pressboard, and the ionization rate of the oil is also intensified, shortening the discharge time at each stage, which indirectly affects the time and morphology of the discharge.

1 September 2023 in High Voltage
Verified
Journal Article
Open access
ZKZhaoyang Kang
Zhaoyang Kang
Fuqiang RenFuqiang Ren
Fuqiang Ren
HZHongru Zhang
Hongru Zhang
JYJingjing Yang
Jingjing Yang
KHKaining Hou
Kaining Hou
HWHuaxin Wen
Huaxin Wen
Basin‐type insulator often has small cracks due to stress concentration. The current method cannot accurately reflect the stress condition of the insulator to find the stress concentration areas. To solve these problems, a method for detecting two‐dimensional plane stress ( δ 1 and δ 2 ) within different depth ranges in a basin‐type insulator is proposed based on critically refracted longitudinal (LCR) wave. First, the acoustoelastic equation characterising the relationship between the variation of LCR wave propagation time and the plane stress was derived. Next, the propagation characteristics of LCR wave in epoxy resin samples were investigated. Then, the stress distribution within different depth ranges of the insulator subjected to hydraulic load was measured using the proposed method, including direction ( θ ), δ 1 and δ 2 . The results show that the magnitude of the stress alone cannot accurately characterise the stress state. Points with equal distances to the centre have similar stress magnitudes, but their directions are not the same. With increasing depth, θ remains essentially unchanged at the same location, while δ 1 and δ 2 decrease, and the rate of decrease varies at different locations. Comparing the measured and simulated data, the results showed that they were in good agreement, and the maximum errors of stress value and θ were 0.69 MPa and 2.97°, respectively, which confirmed the feasibility and accuracy of the stress detection in the proposed method.

7 April 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
XZXiaozhen Zhao
Xiaozhen Zhao
JWJunyi Wei
Junyi Wei
YLYongjun Lv
Yongjun Lv
SYShuaichao Yue
Shuaichao Yue
Fuqiang RenFuqiang Ren
Fuqiang Ren
LYLi Yongjian
Li Yongjian

16 October 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KZKang Zhaoyang
Kang Zhaoyang
HKHou Kaining
Hou Kaining
YGYang Guangdi
Yang Guangdi
WHWu Hongbin
Wu Hongbin
Fuqiang RenFuqiang Ren
Fuqiang Ren
WPWang Peijin
Wang Peijin
With the continuous development of the global energy internet and the increasing power demand, the voltage level of Gas Insulated Transmission Line (GIL) is continually increasing. To meet the operational requirements for higher voltage levels, this paper proposes a novel 550 kV GIL design method based on a 252 kV prototype. Firstly, a multi-stage optimization strategy is creatively proposed through correlation and sensitivity analyses. Secondly, multi-objective optimization techniques, including Response Surface Methodology (RSM), Non-dominated Sorting Genetic Algorithm II (NSGA-II), and Technique for Order Preference by Similarity to Ideal Solution (TOPSIS), are formulated to optimize the geometry and dimensions of key GIL components. The optimization results indicate that the designed 550 kV GIL meets insulation and mechanical strength requirements while achieving significant miniaturization. Compared to the current minimum enclosure radius, the optimized enclosure radius is reduced by 13.39%, and the SF6 gas usage is reduced by approximately 24.70%. Additionally, lightning impulse test and hydraulic test further demonstrate the effectiveness and reliability of the optimized design. This study provides a systematic and efficient approach for designing higher voltage GIL, realizing a more compact and environmentally sustainable solution.