Partial shading (PS) conditions create challenging issues for the maximum power point tracking (MPPT) algorithms in photovoltaic (PV) systems such as getting stuck in the local maximum power points (LMPP), slow tracking time and fluctuations in the generated power during tracking the global maximum power point (GMPP). To address these issues, this article brings contributions by proposing an improved PSO-based MPPT technique tailored for PS conditions. First, to highlight the weakness of the traditional PSO-MPPT technique, its stability and steady state behavior in the PS conditions is analyzed in depth. Second, the required criteria to achieve a stable response are obtained. Finally, a novel technique to estimate the convex area of the power versus voltage (P-V) curve is presented where the GMPP is located using two voltage boundaries. The performance of the proposed MPPT technique is experimentally validated. The results highlight the capabilities of the proposed technique in finding the GMPP with a rapid convergence and small fluctuations. The proposed MPPT is applicable to most PV inverters under any PS conditions.
An islanded microgrid (MG) including low-inertia converter-based distributed generations (DGs) is subjected to instability. The virtual inertia concept was proposed to alleviate the stability issues by imitating the synchronous generators behavior. This paper spotlights on the optimization of virtual synchronous generator (VSG) parameters and virtual impedances (VI) in islanded MGs using particle swarm optimization (PSO). A small-signal model for MG is developed at first. The permissible ranges of virtual inertia (J) and virtual damping (D) based on MG small-signal stability are scrutinized afterwards. Moreover, VI are considered to lower the reactive power mismatch between converters. Finally, considering the permitted intervals for these parameters, an optimization method and objective function are defined to calculate VSG parameters and VI in the islanded MG. The proposed optimization method enhances the small-signal stability of the MG, decreases the current overshoot and minimizes reactive power mismatches. Simulation results drawn by the “VSG + VI” control include three scenarios. The effectiveness of the proposed “VSG + VI” control method in comparison with “droop” control“, droop + VI”“, non-optimal VSG + VI”, and “VSG ” is verified through simulation studies.
The growing importance of Microgrid in future power systems highlights critical challenges like microgrid control and stability. An islanded microgrid including distributed generations (DG), energy storage systems (ESS), and different types of loads (static or dynamic) is prone to instability. The whole microgrid system must be analyzed and designed to operate within stable regions. This study models an inverter-interfaced microgrid which supplies different types of loads such as static loads and symmetrical induction machines (SIM) by virtual synchronous generators (VSG). Afterwards, a generalized small-signal stability analysis framework is proposed for an islanded microgrid. This model is applied for stability analysis of an arbitrary islanded microgrid including several VSGs, lines, static loads, and SIM loads. Subsequently, permissible intervals for VSG parameters are drawn according to the microgrid small-signal stability analysis. These permissible intervals are compared for static and SIM load. Finally, a novel optimization platform is introduced which utilizes the particle swarm optimization (PSO) algorithm to draw optimal values for virtual impedances (VI), virtual inertia (Jv), virtual damping (D), and current state-feedback factor (F). The proposed optimization platform enhances the microgrid stability, minimizes voltage drops on the buses, the reactive power mismatches, and the frequency Nadir, simultaneously.
17 February 2021 in IEEE Transactions on Power Delivery
Inertia requirement is the paramount challenge in future power systems with a significant share of renewable energy generators. A promising solution to this issue is applying Distributed Virtual Inertia (DVI) concept, i.e. releasing energy preserved in the DC–link capacitors of employed power converters in the grid following a frequency disturbance. Nonetheless, small–signal stability analyses affirm that a local mode associated with the control system is prone to become unstable when the grid–interactive converter augmented with the DVI operates in weak grids. To overcome this problem, an efficient compensator is proposed in this paper. This compensator introduces one degree–of–freedom to the direct–axis current controller in synchronous reference frame, which eliminates the adverse impact of DVI function on converter stability. Finally, the efficacy of the proposed control framework is depicted by simulations in MATLAB. The results illustrate that the grid frequency rate of change following a step–up load change is improved by 30% compared to the case in which the DVI loop is nullified.
24 January 2024 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
This paper proposes a control method for virtual synchronous generator (VSG)-based grid-forming converters to improve the stability of power electronic-dominated power grids. Overcurrent protection and fault ride-through (FRT) are crucial for the control of converter-based generators, given the limitations of power electronics components. This paper introduces a finite-set model predictive control (FS-MPC)-based FRT control technique that ensures system stability during symmetrical and asymmetrical fault types by incorporating overcurrent protection and contribution to the system voltage, while maintaining the voltage mode functionalities of the grid-forming converters. Compared to conventional control methods, the proposed MPC control technique allows for faster and improved dynamics, which makes control objectives more accessible. Additionally, the approach coordinates voltage and current control and their limitations to ensure system stability during and after fault. The proposed method also adapts to different fault types and sizes without requiring fault type detection. Simulation results in MATLAB/Simulink illustrate the effectiveness of the proposed control method in limiting the current and ensuring high power quality by providing clean sinusoidal voltage and current waveforms. Hardware-in-the-loop (HIL) real-time simulation is also presented to validate the controller performance under fault conditions.
This paper deals with the development of a control technique for the control of voltage source converters (VSCs) as an interface between renewable energy sources (RESs) and power grids. The lack of inertia in converter-based generators and their unconventional dynamic behavior increase the negative impacts on the power grid, unlike the operation of the conventional synchronous generators (SGs). In this sense, the proposed control technique emulates the behavior of SGs in the control loop of the interfaced converter acting as a grid-forming power generator. Thus, supportive functionalities for enhancing electric grid stability (e.g., frequency oscillation damping) will be provided by interfaced converter as a virtual synchronous generator (VSG). The main targets of the proposed control technique include virtual inertia emulation, frequency oscillation damping, primary and secondary frequency regulation, and voltage regulation. The main contribution of this work over the existing methods is that the optimal values for swing equation parameters are employed to ensure well-designed damping feature of the VSG-based converter which adapts grid-connected and islanded operating modes, enabling a smooth resynchronizing to the grid as its plug-and-play capability requirement. The control structure is evaluated through simulation in MATLAB/Simulink.