Jie He

Jie He

Auto-generated profile, based on publicly available information

Jie He

School of Engineering Medicine, the School of Biological Science and Medical Engineering, and the Key Laboratory of Big Data-Based Precision Medicine, Ministry of Industry and Information Technology of China, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
TZTao Zhu
Tao Zhu
LYLin Yin
Lin Yin
JHJie He
Jie He
ZWZechen Wei
Zechen Wei
XYXin Yang
Xin Yang
HHHui Hui
Hui Hui
Magnetic particle imaging (MPI) uses nonlinear response signals to noninvasively detect magnetic nanoparticles in space, and its quantitative properties hold promise for future precise quantitative treatments. In reconstruction, the system matrix based method necessitates suitable regularization terms, such as Tikhonov or non-negative fused lasso (NFL) regularization, to stabilize the solution. While NFL regularization offers clearer edge information than Tikhonov regularization, it carries a biased estimate of the l 1 penalty, leading to an underestimation of the reconstructed concentration and adversely affecting the quantitative properties. In this paper, a new nonconvex regularization method including min-max concave (MC) and total variation (TV) regularization is proposed. This method utilized MC penalty to provide nearly unbiased sparse constraints and adds the TV penalty to provide a uniform intensity distribution of images. By combining the alternating direction multiplication method (ADMM) and the two-step parameter selection method, a more accurate quantitative MPI reconstruction was realized. The performance of the proposed method was verified on the simulation data, the Open-MPI dataset, and measured data from a homemade MPI scanner. The results indicate that the proposed method achieves better image quality while maintaining the quantitative properties, thus overcoming the drawback of intensity underestimation by the NFL method while providing edge information. In particular, for the measured data, the proposed method reduced the relative error in the intensity of the reconstruction results from 28% to 8%.

18 March 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SLSiao Lei
Siao Lei
JHJie He
Jie He
XHXiazi HUANg
Xiazi HUANg
HHHui Hui
Hui Hui
YAYu An
Yu An
JTJie Tian
Jie Tian
Magnetic Particle Imaging (MPI)-guided Magnetic Fluid Hyperthermia (MFH) has the potential for widespread utilization, as it allows for the prediction of magnetothermal dosage, real-time visualization of the thermal therapy process, and precise localization of the lesion area. However, the existing MPI-guided MFH (MPI-MFH) method is insensitive to concentration gradients of magnetic nanoparticles (MNPs) and is susceptible to causing damage to normal tissues with high MNP concentrations during MFH treatment, while inadequately heating tumor tissues with lower MNP concentrations. In this work, we established a relationship between MNP concentration and heating efficiency through simulations and phantom measurements, enabling the optimal selection of MFH parameters guided by MPI. Based on these findings, we developed a high-gradient field MPI-MFH method using a fieldfree point (FFP) approach to achieve precise local heating. Phantom experiments and in vivo glioma model experiments were conducted to validate this proposed method. The results demonstrated that the proposed method of MPIMFH can improve the MNP concentration gradient sensitivity to ±1 mg/ml, thereby enabling more effective lesion-site heating without damaging normal tissues. This method not only reduced glioma size effectively but also holds promise for application in various other types of cancers.

6 March 2020 in IEEE Access
Verified
Journal Article
Open access
Yushan LiuYushan Liu
Yushan Liu
JHJie He
Jie He
BGBaoming Ge
Baoming Ge
Xiao LiXiao Li
Xiao Li
YXYaosuo Xue
Yaosuo Xue
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
High frequency (HF) ac linked converter functions well to interface between buses with different voltage types. Using a three-phase-to-single-phase matrix converter, a single-phase cyclo converter, and a HF transformer, we can compose a HF ac linked converter to interface between three-phase ac grids and single-phase ac or dc distributed generations (DGs). In this paper, a novel space vector modulation (SVM) method is proposed for such kind of converter. The proposed SVM method converts the mains three-phase ac voltage to a HF ac voltage at the primary side of transformer, and then unfolds the HF ac voltage to a single-phase ac or dc voltage at the secondary side of transformer. Without need to compute separate switching signals for the primary and secondary converters and then coordinate their operations elaborately, the proposed SVM method can be easily implemented by incorporating the HF chopping into the SVM of traditional indirect matrix converter. Therefore, no complicated duty cycle computation or elaborate switching states combination is required. Simulation and hardware-in-loop implementation demonstrate the validity of the proposed method.

2 May 2025 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
WZWenxuan Zou
Wenxuan Zou
GSGen Shi
Gen Shi
SLSiao Lei
Siao Lei
GLGuanghui Li
Guanghui Li
GZGuangxing Zhou
Guangxing Zhou
JTJie Tian
Jie Tian
Recently, Magnetic Particle Imaging, an emerging functional imaging modality, has exhibited outstanding spatial-temporal resolution and sensitivity. The general reconstruction pipeline of Magnetic Particle Imaging involves calibrating a System Matrix and then solving an ill-posed inverse problem combined with the measured particle signals. However, the introduction of noise during the System Matrix calibration procedure is inevitable, which degrades the detailed information in the reconstructed images. Therefore, frequency selection methods based on signal-to-noise ratio are commonly adopted. However, these methods lead to a decrease in the available high-frequency components, which damages the spatial resolution. To address this problem, we propose an unsupervised memory-guided denoising framework with unpaired noisy-clean System Matrix components, called U-N2C. Specifically, we design a Pattern Memory Block to memorize System Matrix patterns, directed by a position-aware frequency index embedding. Meanwhile, we devise a Noise Memory Block to implicitly approximate noise distributions. With the guidance of our dual memory blocks, we can disentangle the noise and content of the System Matrix in the latent space. Furthermore, benefiting from the ability to model complex noise, our method can generate pseudo but high-quality noisy-clean pairs and further enhance our denoising capability. Experiments on both synthetic and real noise demonstrate that our U-N2C achieves cutting-edge performance compared to other methods. Moreover, we conduct extensive qualitative and quantitative ablation studies to verify the effectiveness of our method. Our code has been available at U-N2C.

23 May 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
JHJie He
Jie He
HZHaoran Zhang
Haoran Zhang
YLYimeng Li
Yimeng Li
GLGuanghui Li
Guanghui Li
SLSiao Lei
Siao Lei
JTJie Tian
Jie Tian
Open-sided magnetic particle imaging (OS-MPI) has garnered significant interest due to its potential for interventional applications. However, the system matrix calibration in OS-MPI using sequential scans is a time-consuming task and susceptible to the low signal-to-noise ratio (SNR) resulting from the small calibration sample size. These challenges have hindered the practical implementation of system matrix-based reconstruction for sequentially scanned OS-MPI. To address these issues, we propose a novel calibration method, named sequential scan-based single-dimension multi-voxel calibration (SS-SDMVC), to efficiently obtain a high-SNR system matrix. This method was implemented in a cylindrical field of view (FOV), where a bar calibration sample parallel to the field-free line (FFL) was shifted along a fixed radial direction. A standard image reconstruction process was also introduced to verify the feasibility of SS-SDMVC. Through simulations, we analyzed the effects of noise levels and scanner imperfections on the SS-SDMVC-based reconstruction and demonstrated its robustness. In experiments, we compared the imaging performance of SS-SDMVC and the sequential scan-based traditional cubic-FOV SMC. The results showed that SS-SDMVC reduced the number of measurements by a factor of 210.94 and achieved higher reconstruction quality. Therefore, SS-SDMVC is expected to improve the reconstruction quality of human-scale or high-gradient FFL MPI scanners.

6 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JHJie He
Jie He
HZHaoran Zhang
Haoran Zhang
SLSiao Lei
Siao Lei
GLGuanghui Li
Guanghui Li
YLYimeng Li
Yimeng Li
JTJie Tian
Jie Tian
Magnetic particle imaging (MPI) is an emerging molecular imaging technique that relies on the nonlinear magnetization response of superparamagnetic iron oxide nanoparticles. Open-sided MPI (OS-MPI) has attracted considerable interest for its potential to enhance interventional procedures. However, improving the spatial resolution of OS-MPI poses a significant challenge, mainly due to the inefficiencies of selection coils in generating, rotating, and shifting a high-gradient field-free line (FFL). To address this issue, we propose a novel approach called the permanent magnet-based sequential scan to develop a high-resolution 3-D OS-MPI system with ultralow power consumption. By utilizing permanent magnets, we can create high-gradient selection fields without any power consumption. The sequential scan technique involves rotating the FFL angle by angle and shifting the FFL layer by layer. To maintain thermal stability during sequential scans, we used drive coils wound with hollow copper wires and implemented forced oil cooling. Additionally, measures such as copper shielding, feed-through compensation, and filtering were employed to minimize interference from the permanent magnets, drive coils, and motor drivers. Experimental results demonstrated that the developed system successfully achieved a spatial resolution of 1 mm while operating with an overall low power consumption of 282.16 W.