A pico-ampere sensitive electrochemical sensor signal acquisition chain consisting of a multi-channel bidirectional current-mirror based potentiostat and a multiplexed current-input delta-sigma (Σ) ADC is presented. Slice-based class-AB amplifiers with output stage current replication using reconfigurable current-mirrors enable bidirectional current sensing over a range of five decades. The replicated current is digitized by the ADC. The proposed circuit achieves a minimum detectable current of 91.7 pA, resulting in a dynamic range of 147 dB for sensor currents up to ±1 mA. The potentiostat is operated at a 3 V supply, the ADC at 1.5 V. The static power consumption of a single interface channel depends on the number of active amplifier slices and is between 14.1 W and 39.3 W. The highest power efficiency among similar systems and the low voltage headroom consumption of less than 500 mV enables a versatile use of the interface for multiple sensing applications.
Generic user inputs for pulsed techniques in electrochemical measurement systems result in challenging requirements for the digital-to-analog converter (DAC). This paper presents an application-aware excitation scheme for segmented R-string DACs which minimizes the impact of DAC non-idealities on differential pulse voltammetry (DPV) and normal pulse voltammetry (NPV). The proposed algorithm reduces the step deviation from 90% to 4% when applied to the 16 bit resistor string (R-string) DAC of an integrated circuit potentiostat. Results point out that application-aware DAC control helps to lower demands on the DAC while omitting hardware calibration, thus enabling the realization of low-cost point-of-care (POC) devices.
1 July 2023 in Journal of the Electrochemical Society
There is no standardizedpractice for presenting compliance voltage data generated during a 3-electrode potentiostatic measurement. As a result, engineers are sometimes unaware about the electrical requirements their sensor or cell inhibits. This paper proposes a method to compactly display all electrical information . The introduction of a six region voltage plot, with the cell current plotted in the third dimension, achieves a holistic potentiostat data presentation. The proposed method revealscompliance voltage demands, fosters understanding of a sensor’s electric behavior, enables a comparison of potentiostat capabilities, and most importantly, standardizes results across potentiostat platforms.
There is no good practice to present compliance voltage data generated during a 3-electrode potentiostatic measurement. As a result engineers are sometimes unaware about the electrical requirements their sensor or cell actually inhibits. This paper proposes a method to display all electrical information in a compact manner. Introduction of a six region voltage plot with the cell current plotted in the third dimension achieves a holistic potentiostat data presentation. The proposed method exposes compliance voltage demands, fosters understanding of a sensor's electric behavior, allows to contrast potentiostat capabilities and most importantly makes results comparable across potentiostat platforms.
1 October 2023 in Journal of the Electrochemical Society
Changing electrode potentials during electrochemical measurements requires dynamic positioning of the electrode's reference point at runtime. An analog implementation of a midrange detector circuit serves as the sense part to continuously adjust absolute electrode potentials. The midrange detector topology is based on a sourcefollower winner-take-all circuit and a switched capacitor mean creation. The topology allows simultaneous monitoring of 8 voltage input channels. The maximum error is 100 mV over the commercial temperature range of −20 • C to 70 • C which is equivalent to a 5 bit implementation with analog-to-digital converters (ADCs). With a maximum power consumption of 12.06 pW per decision at a sampling frequency of 1.5 MHz the topology is an efficient way to realize dynamic electrode positioning. The application demonstrates that analog computation when applied with care is resource efficient while still having good performance compared to the strategy of immediate analog-todigital conversion and digital signal processing. This statement is justified by the fact that only the pure analog conversions necessary to reach the specifications would require 12.6 pW with the best published ADCs at the moment.